================================================================================ Intel(R) Server Board S3200SH/S3210SH System Firmware Update Package for Intel(R) Deployment Assistant, Intel(R) One Boot Flash Update Utility, The embedded EFI Shell, Windows* Preboot Execution Environment ================================================================================ Intel Enterprise Platform & Services Division - Marketing Intel Corporation 2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA ================================================================================ DATE : May 21, 2009 TO : Intel(R) Server Board S3200SH/S3210SH SUBJECT : Release Notes for System Firmware Update Package ================================================================================ ABOUT THIS RELEASE ================================================================================ BIOS : S3200X38.86B.00.00.0047 Build Date : Mar 13, 2009 BMC : 31 FRUSDR : 13 ================================================================================ Support Platforms and Dependency ================================================================================ Intel(R) Server Board S3200SH/S3210SH Processors supported: Intel(R) Xeon(R) Processor 3300 Series Intel(R) Xeon(R) Processor 3200 Series Intel(R) Xeon(R) Processor 3100 Series Intel(R) Xeon(R) Processor 3000 Series Intel(R) Core(TM) 2 Quad Desktop processors Intel(R) Core(TM) 2 Duo Desktop processors Intel(R) Core(TM) 2 Extreme processors Microcode update versions: CPUID Microcode 06F2h 5Ah 06F6h CBh 06F7h 68h 06FBh B6h 06FDh A3h 10661h 38h 10676h 60ch 10677h 705h 1067Ah A07h Intel (R) Matrix Storage OpROM: v7.5.0.1017 LSI OpRom : version 10101641 SATA AHCI BIOS : Release Date 01-05-2007 NIC : Intel (R) Boot Agent GE v1.2.60 VGA : VBE BIOS V3.8SL Memory Reference Code 1.00 REVISION INFORMATION RETURNED BY GET DEVICE ID COMMAND: Operational mode : v00.31 UBoot mode : v01.09 Device ID : 0x21 (Integrated BMC 2K7 Firmware) Manufacturer ID : 0x000157 (Intel Corporation) Product ID : 0x003A (S3210SH) Dependency: BIOS must be at R0020 and Integrated BMC FW at v.24 before running this update. ================================================================================ System Firmware Update Package Usage instructions ================================================================================ This package can be updated using one of the following methods: - The embedded EFI shell - Intel(R) Deployment Assistant - Windows* or Linux* operating system using Intel(R) One-boot Flash Update (OFU) v9.70 Build 2 or later) - Windows* Preboot Execution Environment (WinPE) To Update from the embedded EFI Shell update system firmware from Intel server EFI shell by the following steps: - Download Intel server system firmware update package from support.intel.com - Unzip package and copy all files to a folder in USB disk on key - Insert USB disk on key to server USB port - Reboot server to EFI shell - Run command "map -r" in EFI shell to mount USB disk on key - Run command "fs0:" to change folder to USB disk on key, USB key may also mount to fs1:. The number of "fs" is dependent on the result of command "map -r" - Change folder to the folder storing the firmware package - Run command "startup.nsh" to start firmware update process Please refer to "EFI_Instructions.pdf" in this firmware package for a quick guide to use the of EFI commands To Update from Intel(R) Deployment Assistant (IDA) The Intel(R) Deployment Assistant software is easy to use and is present on the "Intel(R) Server Deployment toolkit" CD shipped with the system. User can download the latest version IDA CD ISO image from support.intel.com To use the IDA CD to update the system firmware: - Boot server with IDA CD - Select "Get System Updates" - Choose one of the three options . From support.intel.com Automatically downloads the latest Firmware Update Package from Intel It requires Internet connection Enter your local IP address and proxy configuration Click "Next" to start the download and update process . From my network Download the latest Firmware Update Package from support.intel.com and copy it to a Windows* shared folder Enter your local IP address, the Windows* file server name, and a Windows user name and password Select the firmware package in pop-up window Click "Next" to start the update process . From USB Disk on Key or Hard Disk Download the latest Firmware Update Package from support.intel.com and copy it to a USB key, then insert the key into the server USB port Click "Browse" Select the firmware package in pop-up window Click "Next" to start the update process Note: The Firmware Update Package is in the ZIP file format. Do not unzip before copying to a Windows* shared folder or USB disk. To update from Windows* and Linux* or operating systems using the Intel(R) One Boot Flash Update Utility (OFU) Intel(R) One boot Flash Update utility can be downloaded from support.intel.com and it is part of the "BIOS, Firmware Update & Configuration Utilities" for Windows* and Linux*. Please refer to Intel OFU user guide about the details of installation and usage of OFU. Use OFU to update system firmware by the following steps: - Install OFU on Windows* or Linux* system - Download the latest firmware update package from support.intel.com - Unzip package to a folder - Run the following command in Windows* command line/Linux* terminal window: :\flashupdt -u \flashupdt.cfg To update from Windows* Preboot Execution Environment (WinPE) The System Firmware Update Package can be inserted to Windows* PE customized image for creating a bootable Windows* PE CD. User is able to update system firmware from customized WinPE CD by the following steps: - Boot server with customized WinPE CD - Run script "WinPE20_x86_Update.bat" (name may be varied depends on your own customization) Note: 1. The Intel(R) OFU utility is case sensitive. Therefore, when you transfer the Firmware Update Package using USB key from a Microsoft Windows* system to a Linux environment, you must first extract under the Microsoft Windows* environment. Otherwise, you will need to mount the USB key manually with ¡°vfat¡± option under Linux to avoid conversion from upper case to lower case and vice versa. 2. In this SFUP package, Intel only provide batch file "WinPE20_x86_Update.bat" for WinPE2.0 32 bit solution as an example. Please refer to white paper "White Paper-Intel Server Utilities Procedure for WinPE.pdf" for details on building your own customized WinPE CD. 3. Windows PE 2.0 - built from Windows Vista SP1 32bit ================================================================================ BIOS Changes since release ================================================================================ BIOS R47 Issues Fixed: - PS2 Keyboard/Mouse can not work with E5200 CPU. - Front panel USB port can not recognize USB1.1 device. BIOS R46 Issues Fixed: - PCI-E Network Adapter Wake On LAN can't power on monitor issue. Added: - EFI bootable support BIOS R45 Issues Fixed: - CPU family name change from "Core 2 Duo" to "Core 2" Added: - Add USB device boot priority item in setup. - SMS 3.0 IPMI set Boot device order command support. - Add "FWVERSIONDATA" NVRAM variable to support OA2.0. - OHCI USB card support. BIOS R44 Issues Fixed: - N/A Added: - E-0 and R-0 CPU microcode support. ================================================================================ BMC Changes since release ================================================================================ BMC FW31 Issues Fixed: - BMC firmware crashes when telnet to it - HSC Get Buffer Size command returns extra one byte BMC FW30 Issues Fixed: - SYSFAN3 and SYSFAN4 speeds are going low when rebooting the system from Windows BMC FW29 Issues Fixed: - FRUSDR.EFI's PROBE "PING" command does not work with HSC - IPMB communication to HSBP fails and hangs IPMB - Not able to update BP6 firmware ================================================================================ FRUSDR Changes since release ================================================================================ FRUSDR 13 Issues Fixed: - N/A FRUSDR 12 Issues Fixed: - Removed possible long delay when checking for HSC FRUSDR 11 Issues Fixed: - N/A Added: - Message when detecting HSC for notification of possible long delay ============================================================================= LEGAL INFORMATION ============================================================================= Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel Corporation may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a registered trademark of Intel Corporation. *Other names and brands are the property of their respective owners. Copyright (c) 2009 Intel Corporation. A portion of this firmware is open source code, which falls under the GPL 2.0 license. [END OF RELEASE NOTES]