Intel(R) Corporation

Intel® SR2050 Server Chassis

The products you are looking for are no longer manufactured by Intel. Additionally, Intel no longer provides interactive support for these products via telephone or e-mail, nor will Intel provide any future content updates or software updates to support new operating systems or improve compatibility with third party devices and software products.

THESE PRODUCT SUPPORT DOCUMENTS ARE PROVIDED FOR HISTORICAL REFERENCE ONLY AND ARE SUBJECT TO THE TERMS SET FORTH IN THE "TERMS OF USE" INFORMATION.

Information on currently available Intel products is available at www.intel.com and/or developer.intel.com


Identify your products
Product Discontinuance Announcement
Intel® will no longer provide interactive support for these products via telephone or e-mail.

Software and drivers
BIOS/Firmware, drivers, and utilities

Technical specifications
Technical Product Specifications
Product overview, including descriptions and diagrams of the integrated features
icon Technical Product Specifications [PDF]

Specification update
An update to the specifications contained in the Technical Product Specification.
icon Specification Update [PDF]

Installation and use
Chassis intrusion switch doesn't fit with STL2 and SR2050
There is not enough clearance to attach to the 6A connector because the PCI add-in card is indented. Connect to jumper 1L4, pins 3-5.

General Fault LED Stays Lit
Possible causes
  1. Power supply is bad.
  2. A system fan is bad.
  3. The front panel cable that is being used is not the right one for the server board. Please see TA-306-x for further information.
  4. The CPU fan for CPU 0 is plugged into the Y position fan connector (System fan connector FAN1A (P11)). The CPU fan should be plugged into the fan connector in position AA (Primary processor heatsink fan connector (P12)) in the upper left hand corner of the server board. (See page 6 of the Intel® STL2 Server Board Quick Start Guide).

Hot Swap Controller (HSC) firmware update is not possible
The Intel® STL2 Server Board and Intel® SBT2 Server Board do not support an I2C interface connection between the server board and the chassis' hot swap backplane / SAF-TE card. An Intel® L440GX+ Server Board may be installed in the chassis in order to perform the HSC firmware update.

Product Guide - English
icon ENGLISH [PDF]

Product Guide - Spanish
icon SPANISH [PDF]

Unable to boot Teac* CD-ROM
Use a Teac* CD-ROM model -B83 instead of -B93.

Compatibility
Tested Server Boards
Intel® STL2 Server Board

Technical advisories
TA 0337: Installing STL2 PCI Flex Riser
icon TA_337-1 [PDF]

TA 0347: Hard Drives Marked Offline with L440GX+
icon TA_347 [PDF]

TA 0351: Hard Drives Marked Offline with SBT2 or STL2
icon TA-351 [PDF]

TA 0402: ICP* RAID Controllers Require New Hot Swap Controller Firmware
icon TA_402 [PDF]