Intel® RAID Controller SRCU32 |
The products you are looking for are no longer manufactured by Intel. Additionally, Intel no longer provides interactive support for these products via telephone or e-mail, nor will Intel provide any future content updates or software updates to support new operating systems or improve compatibility with third party devices and software products. THESE PRODUCT SUPPORT DOCUMENTS ARE PROVIDED FOR HISTORICAL REFERENCE ONLY AND ARE SUBJECT TO THE TERMS SET FORTH IN THE "TERMS OF USE" INFORMATION. Information on currently available Intel products is available at www.intel.com and/or developer.intel.com |
Intel® will no longer provide interactive support for these products via telephone or e-mail
Product overview, including descriptions and diagrams of the integrated features
Technical Product Specifications [PDF]
An update to the specifications contained in the Technical Product Specification
Install the RAID Software Suite for Windows NT* 4.0 and 2000 StorCon [WIN_RSS.EXE]
1-3: Controller startup was successful.
4: Possible disk failure. Run Storage Console to check status.
2-2: Memory or firmware issue. Install new memory, or perform a firmware recovery.
This controller cannot perform hardware clustering
Settings Default Value
Cache On
Delayed Write On
BIOS Enabled
BIOS Warning Level Fatal errors
SETUP from Flash-RAM Enabled
Display
Supported BIOS Drives 2
CD-ROM Boot Disabled
Memory Test Standard
Halt on Firmware messages On
SES Support Enabled
Immediate Hard Disk start On
Chn. SCSI-A: Termination Set by jumper or N/A (dependent upon the specific RAID controller)
Chn. SCSI-A: SCSI-ID 7
Chn. SCSI-A: Domain Validation On
Periodic Parity Verify None
Storcon > F4 for Advanced > Configure Physical Devices > ESG-SHV SCA HSBP > Enclosure Slot Configuration > Select drive slot > Enter to include the drive in the SAF-TE configurationStorcon > F4 for Advanced > Configure Physical Devices > ESG-SHV SCA HSBP > Enclosure Slot Configuration > Select drive slot > Enter to include the drive in the SAF-TE configuration
Use the Email Notification option in the RAID Configuration Service. This uses SMTP instead of MAPI to send the email notification.
Enter StorCon - Advanced - Physical Devices. Select the SCSI ID listed in the error message, and press F8 to Repair.
Storcon > F4 for Advanced > Configure Physical Devices > ESG-SHV SCA HSBP > Enclosure Slot Configuration > Select drive slot > Enter to include the drive in the SAF-TE configuration
Remove the drive with the "outdated" data from the array and rebuild the mirror on a clean drive.
The port configuration needs to be imported to be recognized by Intel® Embedded RAID Technology I before a RAID array can be created or deleted.
Enter the RAID OptionROM (CTRL+E during boot) > Main menu > Configure > press ‘Enter’ on the port > Import the configuration
'+5V @ 0.25 Amps = 1.25W
+3.3V @ 2.5 Amps = 8.25W
.txt or .evt files can be read with any plain text editor.
Possible disk failure. Run Storage Console to check status.
Last Status code of 0x0000010F indicates that the controller attempted to do a normal disconnect operation with the device, but was unable to do so for a timeout period of 30 seconds. Disable SCSI Disconnects in StorCon > Advanced > Configure Physical Devices > Device> SCSI Parameters / Initialize > Disconnect > Disable
In StorCon, under Advanced Setup > Configure Controller, press < F4 > to silence alarm. In StorCon+, in the Physical Configuration view, right click on the icon of the controller requiring alarm deactivation. Click Silence to deactivate alarm.
The hotkey option to enter the Option ROM is disabled by default.
To display this option, the Intel® Quiet or Silent Boot options need to be disabled in the BIOS. This will disable the Intel splash screen during POST displaying the hotkey option for the option ROM.