This release note and the software that accompanies it are copyright (c) 2014, Intel Corporation or its suppliers, and may only be installed and used in accordance with the license that accompanies the software. This Software is furnished under license and may only be used or copied in accordance with the terms of that license. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. The Software is subject to change without notice, and should not be construed as a commitment by Intel Corporation or its suppliers to market, license, sell or support any product or technology. Unless otherwise provided for in the license under which this Software is provided, the Software is provided AS IS, with no warranties of any kind, express or implied. Except as expressly permitted by the Software license, neither Intel Corporation nor its suppliers assumes any responsibility or liability for any errors or inaccuracies that may appear herein. Except as expressly permitted by the Software license, no part of the Software may be reproduced, stored in a retrieval system, transmitted in any form, or distributed by any means without the express written consent of Intel Corporation. ========================== Supported RAID Controllers ========================== This download supports Intel(R) RAID controllers using SAS software stack (RS2WC080, RS2WC040, RMS2AF080 and RMS2AF040), please verify that this utility has been tested with the RAID card you have chosen to use by checking the drivers web page for your controller at http://support.intel.com. =================== Package Information =================== Flash package = v20.12.1-0168 (firmware 2.130.394-3028) ========== Attention! ========== Intel recommends to loading Factory Default setting after the firmware upgrade which will not affect data on any existing array. To do so: 1. Reboot the system and login to the RAID BIOS Console. 2. Select the controller and select 'Adapter Properties'->'Next' 3. Set the 'Set Factory Defaults' setting to 'Yes' and submit the change. 4. Reboot the system (the default settings are applied). 5. Re-configure to the desired settings in RAID Web Console2. ================== Known Restrictions ================== 1) This download does NOT support EFI v1.1 environment. Please use the EFI shell command "ver" to identify the EFI version. 2) When 2 or more VDs are created, VD cache settings must be the same. ======================= Contents on the package ======================= The following files are included in this zip: Name: Description: COPYING.NEWLIB.txt License Agreement IMR411p.rom Firmware binary ir3_2008SASHWR_FWPKG-v20.12.1-0168_readme.txt This file License_v2.pdf License Agreement update.bat DOS firmware update batch file update.nsh UEFI firmware update batch file CmdTool2\DOS\* DOS update utility and support files CmdTool2\FreeBSD\* FreeBSD update utility and support files CmdTool2\Linux\* Linux update utility and support files CmdTool2\Solaris\* Solaris update utility and support files CmdTool2\UEFI\* UEFI update utility and support files CmdTool2\Windows\* Windows update utility and support files ========================== Installation instructions: ========================== UEFI (EFI 2.0) instructions for updating RAID Firmware: ----------------- 1. Download and extract all files to a local drive. 2. Boot the target system to EFI shell. 3. Change directory to the local drive and directory containing the flash update files and the firmware image file. 4. Type "update.nsh" or "efi\cmdtool2 -adpfwflash -f IMR411p.rom -aall" 5. Wait for the flash to complete. Do NOT reboot the system during the update. DOS instructions for updating RAID Firmware: ----------------- 1. Download and extract all files to a local drive. 2. Boot the target system to DOS. 3. Change directory to the local drive and directory containing the flash update files and the firmware image file. 4. Type "update.bat" or "dos\cmdtool2 -adpfwflash -f IMR411p.rom -aall" 5. Wait for the flash to complete. Do NOT reboot the system during the update. Windows and Linux instructions for updating RAID Firmware: ----------------- The firmware update may be run from Within Windows or Linux using the appropriate versions of CmdTool2. In Windows, unzip the utility into the same directory as the rom file by typing "cmdtool2 -adpfwflash -f IMR411p.rom -aall". The Linux CmdTool2 by running the rpm and then calling the utility from /opt/MegaRAID/CmdTool2 as "./CmdTool2 -AdpFwFlash -f IMR411p.rom -aall" You can also use RAID Web Console 2 to update the RAID firmware. For more detail, please refer to the Intel(r) RAID Software User's Guide. ============= Package Details/Fixes/Updates ============= Package - 20.12.1-0168 (4.11 Patch) Firmware 2.130.394-3028 SCGCQ00426160 - MegaRAID iMR FW with "enableReducedFeatureSet=1" issue SCGCQ00475764 - after the newest image is installed, servers often will not boot. SCGCQ00475589 - FW sending wrong configuration data during boot msg pending state SCGCQ00466496 - Not able to change the properties of MSM. SCGCQ00463043 - Upgrading from Software RAID to 9260-8i causes Alarm to sound SCGCQ00455655 - Error in MR_DCMD_CTRL_EVENT_COUNT/SL_DIR_READ SCGCQ00454839 - MSM log warning: Controller booted in headless mode with errors SCGCQ00426916 - Data Corruption with R5 cachedIO mode SCGCQ00349837 - Sequential Read performance is less on CacheCade associated LD's. SCGCQ00467839 - Montask occurs when running host i/o and parallel OOB command SCGCQ00464657 - Generic point release MR4.9 :VPD output of lspci vvxxx showing [RV] Reserved: checksum bad, 86 byte(s) reserved SCGCQ00450935 - When pinned cache present VD property not changing from WB to WT. SCGCQ00440568 - 9260-8i(SAS2108) hitting OOB SRAT timeout for a long time causing OOB commands to fail SCGCQ00584561 - Check-in Pl version 5.0.42.0 -- Improve STP connection timing behavior with idle connections SCGCQ00558885 - Checking-in new PL version :05.00.41 SCGCQ00488348 - To check-in new PL version 5.00.40.00 SCGCQ00427464 - Discard preserved cache takes excessive time or hangs SCGCQ00458860 - Controller always gives an event MR_EVT_CTRL_BOOT_HEADLESS_MODE_HAD_ERRORS if controller is set in HSM mode. SCGCQ00457324 - Montask occurs when running host i/o and parallel OOB command SCGCQ00455014 - PDs go online without VD created & App doesn't allow any VD creation on passing a wrong parameter in Spanned VD. SCGCQ00456152 - To Disable the logging of event MR_EVT_PD_EMERGENCY_SPARE_COMMISSIONED_REMINDER SCGCQ00479336 - EEprom CRC error is detected when WebBIOS is running SCGCQ00491037 - STP Passthrough Support through OOB SCGCQ00471180 - FW is not declaring the battery bad if learn cycles fail continuously SCGCQ00467625 - Validate the requested blocks for SCSI VERIFY commands on RAID volumes SCGCQ00451971 - see 9261-8i emergency spare being commissioned SCGCQ00437904 - Data Miscompare found while running I/O overnight with degraded virtual drives SCGCQ00456777 - FW halts when you have pinned cahce and remove VD form the configuration. SCGCQ00458859 - FW halts when you have pinned cahce and remove VD form the configuration. SCGCQ00462516 - Card Running iMR Machine Checks when Requesting Host Memory SCGCQ00478812 - Minimum Capacity needed for relearn is incorrect in 2208 MR FW SCGCQ00558100 - Incorrect variable type in MR Read/Modify/Write path SCGCQ00558115 - RM_SataBBMTotalCount always return 0 SCGCQ00558947 - FW Automatically detect backplane SGPIO type to set the driveactivityLED parameter SCGCQ00559344 - Setting the ASO key with storcli 1.02.08 (MegaCli 8.07.06) fails with an error code 3 on Windows or Linux if the MB BIOS PCI SCGCQ00451982 - Discard preserved cache takes excessive time or hangs SCGCQ00433403 - During rebuild on PRL11 CacheCade VD and rebuild on RAID6 Source VD IO integrity error is seen. SCGCQ00433391 - IO integrity error seen after Source VD associated with CacheCade VD is forcibly unblocked SCGCQ00579790 - LDBBM on RAID6 not eligible SCGCQ00458879 - PCIe core has received a PCIe request that it does not support SCGCQ00459017 - Firmware returns asc value as 0 when failing IOs with medium errors SCGCQ00475895 - Firmware hits Montask when drive is pulled after changing the volume property from read ahead to no read ahead. SCGCQ00476387 - Faulty protocol used for changing the Disk Write Cache Policy SCGCQ00487207 - BU SOH bad message be posted after exhauting retry attempts. Stop monitoring battery once SOH bad is declared SCGCQ00487654 - RHEL6.4 Kernel crash after reboot SCGCQ00488061 - Medium error correction event is not logged during CC SCGCQ00558908 - Firmware Version 2.130.383-2912 is hitting MonTask at line 1209 in file ../../raid/1078dma.c SCGCQ00449634 - Source VD gets blocked on OCR after one PD removal from R0 WB CCVD and reuse of that PD in creating another CCVD. SCGCQ00447651 - Data Corruption seen when IOs are in progress and cachecade PD is marked as missing and reused to create another SSC VD. SCGCQ00433563 - Sequential Read performance is less on CacheCade associated LD's. SCGCQ00433409 - When a Cachecade PD marked as missing is reused to make Cachecade VD IO integrity error is observed. SCGCQ00434393 - Saved Release Note DataSLIB returning bad data as good data after host reboots SCGCQ00458876 - (Vital Product Data) needs to identify PCB hardware level SCGCQ00476060 - Validate the requested blocks for SCSI VERIFY commands on RAID volumes SCGCQ00476108 - If a BOOT Passphrase is enabled with SafeStor "MegaCli adpbios dsply a0" will display "BIOS will Stop on error" even if any other mode is set. SCGCQ00488447 - Update the events SCGCQ00558950 - Firmware is not updating recovery timer as intended SCGCQ00484210 - "chip paused" causes high service time on all drives SCGCQ00450646 - 9260-8i(SAS2108) hitting OOB SRAT timeout for a long time causing OOB commands to fail SCGCQ00583755 - Raid configuration loss after reboot - PDs in POWERSAVE SCGCQ00487664 - Code Review: Call DDF_discardInvalidPds only if DS3 is enabled SCGCQ00558924 - Upgrading from Software RAID to 9260-8i causes Alarm to sound SCGCQ00479291 - system black screen during S1 Sleep test NVDATA 3.09.03-0054 BootBlock 2.02.00.00-0001 ROMENV 1.08 WebBIOS 4.0-60-e_49-Rel PCLI 03.02.20 SCGCQ00477036 - UEFI driver issue with platforms when user having 2TB or 4TB VD SCGCQ00484087 - platfrom has UEFI hang when SATA is connected SCGCQ00492562 - Disable Debug print in UEFI Driver SCGCQ00492563 - Block IO tests from SCT IHV test suite failed SCGCQ00484115 - ATA PT: Follow UEFI Spec on interpreting In and Out Transfer Length that upper layer sends UEFI_Driver 0x05290000 Hii 1.38.00 SCGCQ00492564 - Obtain the Physical Slot number from the PCI Bridge to which the Controller is connected. BIOS 4.37.00 SCGCQ00455591 - Memory access issue for when loading Ctrl R SCGCQ00455597 - Memory allocation: Allocate only two 64k FCODE 4.14.05.00 Package - v20.12.1-015 (MR4.11) Firmware - 2.130.394-2550 SCGCQ00395533 - CC schedule is changed to an unjust date by "Configuration Clear" SCGCQ00349837 - Sequential Read performance is less on CacheCade associated LD's. SCGCQ00396335 - 9260-16i's drive locate/fault LED header is not working properly. SCGCQ00361312 - MR4.7 FW reports detected problem with iBBU07 charging circuit SCGCQ00360938 - When attempting to secure LD during RLM, receive option to secure LD, LD not secured (message incorrect/misleading.) SCGCQ00392840 - Prevent overtemp warnings while charging SCGCQ00399692 - Modify MR fw to eliminate four second window where drive swap is not recognized. SCGCQ00406955 - Prevent data correction in pagefil.sys to happen during Check Consistency after heavy I/O test. SCGCQ00422473 - When a Cachecade PD marked as missing is reused to make Cachecade VD IO integrity error is observed. SCGCQ00432851 - Saved Release Note DataSLIB returning bad data as good data after host reboots SCGCQ00436896 - Minimum Capacity needed for relearn is incorrect in 2208 MR FW SCGCQ00447652 - Potential data integrity issue seen when IOs are in progress and cachecade PD is marked as missing and reused to create another SSC VD. SCGCQ00448732 - Card Running iMR Machine Checks when Requesting Host Memory SCGCQ00449871 - Verify drive reinsertion within/before drive-removal-delay setting -verify discovery (Without IO) SCGCQ00414148 - Firmware returns invalid data in OOB packet SCGCQ00437920 - Data Miscompare found while running I/O overnight with degraded virtual drives SCGCQ00439197 - Potential data integrity issue with R5 cachedIO mode SCGCQ00421933 - IO integrity error seen after Source VD associated with CacheCade VD is forcibly unblocked SCGCQ00423725 - Sequential Read performance is less on CacheCade associated LD's. SCGCQ00421891 - Assertion failure in ../../raid/raidpci.c at line 8323 while running IO with cable pull/push. SCGCQ00421960 - During rebuild on PRL11 CacheCade VD and rebuild on RAID6 Source VD IO integrity error is seen. SCGCQ00450056 - Source VD gets blocked on OCR after one PD removal from R0 WB CCVD and reuse of that PD in creating another CCVD. SCGCQ00338466 - Not able to flash both 9265-8i and 9285-8e card with 5.3 patch 1 firmware SCGCQ00340840 - Don't interpret the cachecade BVD flags if the volume is created with old FW which does not support cachecade. SCGCQ00357643 - Possible data integrity issue during Raid Level Migration SCGCQ00359356 - Offline drive becomes automatically online during Raid Level Migration SCGCQ00363555 - Bad disk being serviced hung Linux boot for 2 hours SCGCQ00365307 - Offline drive becomes automatically online during Raid Level Migration SCGCQ00369276 - VD is degraded(automatically) after raid level migration R1 TO R5 (adding one drive) SCGCQ00369346 - VD is degraded(automatically) after raid level migration R1 TO R5 (adding one drive) SCGCQ00374525 - Firmware enters megamon by system reboot after changing MFC OEM SCGCQ00307050 - Not able to flash both 9265-8i and 9285-8e card with 5.3 patch 1 firmware.However, it is ok on 9266-8i. SCGCQ00338490 - Invalid target ID after new logical drive creation SCGCQ00341791 - Support for mutlipath topology is broken SCGCQ00361303 - on iMR FW update caused card to FW fault state and card cannot boot to OS. SCGCQ00371477 - During Reconstruction (R0->R5) when system reboots the reconstruction doesnt resume. System hangs Megamon hit SCGCQ00375250 - BMC see clock stetching on I2C bus SCGCQ00375854 - adapterOperations.alarmControl is being set to 1 even if controller doesnot have alarm on board SCGCQ00384381 - Drive temperature is shown very high on 9240 SCGCQ00391094 - 9260-16i's drive locate/fault LED header doesn't work SCGCQ00392062 - Firmware halts when flashing components other than app.rom for OEM SCGCQ00392063 - PL library and files checkin for PL version 5.38 SCGCQ00363619 - Set the Recovery mode page (WriteRetryCount and recoveryTimeLimit) BIOS - 4.36.00 FCODE - 4.12.05.00 UEFI_Driver - 0x05270000 HII - 1.37.00 SCGCQ00395508 - System with SSD HDD will pop up an error message after creating VD via HII PCLI - 03.02.20 WebBIOS - 4.0-60-e_49-Rel SCGCQ00386062: Unable to read the correct value of controller property "Boot Error Handling" after changing NVDATA - 3.09.03-0052 SCGCQ00393134: Change the showSgpio activity to 0 SCGCQ00350995: Requested changes from Channel Factory Defaults for MFC values SCGCQ00411296: iMR FW NVDATA change for global fault/activity LED BootBlock - 2.02.00.00-0001 ROMENV 1.08 Package v20.11.1-0135 (MR4.10p) Firmware - 2.130.384-2166 SCGCQ00341980 - Current Access policy is not getting updated for iMR SCGCQ00353935 - Add support for Ringbuffer and Dq compilation SCGCQ00356925 - disableHII: Needs to be updated from nvdata into MFCD SCGCQ00357046 - 9240-4i on particular motherboard is not getting required memory resources on boot SCGCQ00349562 - Unable to open "Set Patrol Read Properties" in MSM with 2008-iMR SCGCQ00362340 - multi path with Consistency Check LED behavior problem SCGCQ00342405 - Enable or disable 512E using Applications SCGCQ00342397 - Provide the count of LBAs that are present in the sata bbm table. SCGCQ00350996 - Fail the IO in case the medium error recovery is taking more time. SCGCQ00359200 - offline drive becomes automatically online during Raid Level Migration SCGCQ00371803 - During Reconstruction (R0->R5) when system reboots the reconstruction doesnt resume. System hangs. SCGCQ00358361 - Bad disk being serviced hung Linux boot for 2 hours SCGCQ00373802 - Auto Foreign import fails when controller is booted with pinned cache. FCODE - 4.12.05.00 UEFI_Driver - 0x05270000 SCGCQ00347171 - MR: on having pinned cache on OEM controller, the option to invoke storage dosent come. SCGCQ00369636 - UEFI: Settime only when FW time is not set; DHP: Return appropriate health status when there is no critical boot message SCGCQ00340581 - UEFI Driver should check pMRCtrlInfo ->maxHANodes with > 1 SCGCQ00318101 - Timed critical boot message under UEFI mode SCGCQ00347492 - UEFI: Retry read capacity if scsi status is not success SCGCQ00310476 - Load HII when user responds to critical boot message by pressing C BIOS - 4.35.00 Hii - 01.36.00 SCGCQ00268038 - Hii enter black screen/timeout when user switching between fields/form sub_form and during Pd rebuild. SCGCQ00364156 - Remove debug message which is not applicable for non Mercury customers NVDATA - 3.09.03-0045 WebBIOS - 4.0-59-e_48-Rel PCLI - 03.02.20 BootBlock - 2.02.00.00-0001 ROMENV - 1.08 Package v20.10.1-0126 (MR4.9) Firmware 2.130.374-2023 SCGCQ00262426 - If VD is secured while reconstruction is going on does not stay secured once reconstruction is done. SCGCQ00313883 - Battery continually stating Battery Yearly Deep Discharge Relearn Pending. Please Initiate a manual Relearn SCGCQ00319537 - System hang on IBM machine with a critical boot message SCGCQ00327006 - Event (MR_EVT_CTRL_RESETNOW_DONE ) is not generated after OFU is completed SCGCQ00329851 - EEPROM corruption(BQ2060 errata) due to corrupted value of design Capacity written in FCC for iBBU07 SCGCQ00332181 - INVALID SGL causes dump into montask, OCR does not recover. MonTask: line 377 in file ../../dm/mpt2/mptrec.c & MonTask: line SCGCQ00333679 - reverting the changes of SCGCQ00295604 SCGCQ00333696 - EEPROM corruption(BQ2060 errata) due to corrupted value of design Capacity written in FCC for iBBU07 SCGCQ00334032 - Code review checkin SCGCQ00335607 - Firmware upgrade/downgrade not possible due to missing env stamping SCGCQ00336716 - Megamon issue when disabling the drive security on a MR controller with spun down FDE drives. SCGCQ00337894 - OFU is not happening when tried to upgrade firmware. SCGCQ00338008 - Flash of package with OFU request SCGCQ00345497 - Code review: With the new approach for CtrlOFUPossibleSet/Get() shutdown path broken SCGCQ00346275 - Copyback on a drive hits kill adapter SCGCQ00347253 - Firmware fails to return proper value when flashed same firmware image with different stamping with OFU request. SCGCQ00353344 - Data Corruption during Raid Level Migration SCGCQ00335935 - Coverity Defect fixes SCGCQ00286152 - GetConnectorIndex() Out of bound array access SCGCQ00334889 - Multiple switch cases are not handles correctly in debug functions SCGCQ00314781 - Controller always enter HSM when it is set to HCOE SCGCQ00317767 - Code Review Defect: Correct the error in copy back path smart errors path SCGCQ00333346 - Dont interpret the cachecade BVD flags if the volume is created with old FW which does not support cachecade. SCGCQ00340772 - Address Action Item SCGCQ00340495 (Check coding standard for structure OfuRequestState) SCGCQ00332658 - Out-of-bounds access (OVERRUN_STATIC) of an array "ar" in pdCopyBackSpinupCallBack SCGCQ00332651 - Out-of-bounds access (OVERRUN_STATIC) of an array "nvInfo->lockKeyBlob.keyCheck" in displayNvKeyInfo SCGCQ00329070 - Coverity Defect SCGCQ00315029 - PD clear operation is not handle correctly with spun drive drives SCGCQ00332588 - Fix coverity defects 10216 and 10425 (overrun and potential NULL pointer access) SCGCQ00307050 - Not able to flash both 9265-8i and 9285-8e card with 5.3 patch 1 firmware.However, it is ok on 9266-8i. SCGCQ00353322 - Unable to enable ocr using application due to FW ocr setting taking precedence SCGCQ00328109 - Out of bound access in LDBBMListInit SCGCQ00337060 - Coverity Defects SCGCQ00341791 - Support for mutlipath topology is broken SCGCQ00330344 - FW halts with a a kill adaptor on performing an onffline of the drive under copyback. line 1188 in file ../../raid/1078dma.c SCGCQ00332099 - Out-of-bounds access (OVERRUN_STATIC) of an array "ar" in pdDcmdRebuildCB SCGCQ00302600 - Added more debug information SCGCQ00307949 - True FW Online update for Liberator SCGCQ00307950 - BGI is in endless loop continuously restarting after completion SCGCQ00308988 - Improve foreign config import for iMR with mixed JBOD/RAID settings SCGCQ00314258 - Need the ability to determine what disk a logical LBA associate with on the fly, api call/algorithim/etc. on Liberator SCGCQ00323446 - Add NVDATA support to make 512 Emulated drive support as configurable for customers. SCGCQ00345203 - megacli reports battery pack is missing on hot insertion SCGCQ00314965 - iBBU07 - SOH bad will be declared for low capacity battery before starting learn cycle SCGCQ00307956 - iBBU07: EEPROM and register values will be updated to revised values at first boot after FW flash. BIOS - 4.34.00 UEFI Driver 0x05210000 SCGCQ00262858 - Debug message is shown from EFI app choice prompt SCGCQ00308870 - EFI Driver 518\When disconnecting the driver in EFI, I am still able to exectue the EFI utility menu. SCGCQ00312683 - UEFI Driver not timing out in 3 mins when FW is in undefined state SCGCQ00320619 - UEFI: Build Device Path and Get Next Target function of SCSI Pass Thru is not returning correct EFI status for certain cases SCGCQ00335617 - Drives are reporting timeout on Write Buffer cmd SCGCQ00339371 - UEFI Driver fails SCT Test SCGCQ00343869 - Enhance critical boot message handling SCGCQ00338066 - UEFI - HAMR: Fire LD list query based on maxHANodes SCGCQ00338782 - If SetOptions is called for Invader dont show EFI WebBIOS and EFI CLI option SCGCQ00340581 - UEFI Driver should check pMRCtrlInfo ->maxHANodes with > 1 to determine HAMR HII 1.33.00 SCGCQ00318010 - Allows to select Cachecade VD as Boot device SCGCQ00319005 - HII will not allow config to be cleared no drives attached SCGCQ00319010 - HII while in safe mode locks up when entering View drive SCGCQ00293056 - HII: LSIP200198414/LSIP200229508/LSIP200231613: Disables all requirement for human input at boot time SCGCQ00317934 - Add MFI State error string for the new MFI stat error codes SCGCQ00317991 - Remove 'Adaptive Read Ahead' option from every MegaRAID management utility (PR: SCGCQ00295908) FCODE 4.12.05.00 NVDATA 3.09.03-0045 - Code review: correcting the delivery error - Disable emergencyspare for a customer WebBIOS 4.0-59-e_48-Rel PCLI 03.02.20 ROMENV 1.08 BootBlock 2.02.00.00-0001 Package v20.10.1-0119 (MR4.8) Firmware 2.130.364-1847 SCGCQ00308820 - Bbumode is 5 instead of 0 for iBBU07 SCGCQ00311062 - Fatal firmware error: Line 1842 during FC import SCGCQ00284536 - 9260 controller VD goes offline during Slow/Full/Foreground Initialize with 3TB Seagate SED SAS drives SCGCQ00301160 - Limited band Charging for all OEMs SCGCQ00298687 - Code Review defect to handle SA_INVALID_FIELD_IN_CDB SCGCQ00292830 - FW correctly removes entries in the SBBM table by properly shifting the entries to the right. SCGCQ00292943 - Allocate BBLog for iMR Initally during boot up SCGCQ00295474 - BBU mode is set to 5 for BBU07 in ctrl-h SCGCQ00294981 - FW Montask on every boot SCGCQ00252606 - Drive fails after I/O timeout and subsequent target reset during continuous firmware flash. SCGCQ00284230 - Megamon during Injecting errors to VD with 512e PDs on iMR controller SCGCQ00295130 - spare pointer is incorrectly used in MR_CONFIG_DATA SCGCQ00290512 - Checked in the review comment for SCGCQ00286613 SCGCQ00313883 - Battery continually stating Battery Yearly Deep Discharge Relearn Pending. Please Initiate a manual Relearn SCGCQ00319537 - System hang on OEM machine with a critical boot message SCGCQ00263446 - Support SGPIO SideBand with/without Activity SCGCQ00296744 - enable Emergency hotspare capability for channel SCGCQ00323446 - Add NVDATA support to make 512 Emulated drive support as configurable for customers. SCGCQ00286613 - ER corresponding to LSIP200230920 SCGCQ00290530 - Band Gap charging for iBBU08 SCGCQ00288679 - ER corresponding to LSIP200122939 SCGCQ00290531 - Learn Improvement - Do not take Command block if there is no LD for which cache policy will change NVDATA 3.09.03-0045 SCGCQ00324305 - Added enable512eSupport parameter in MR PARAMS PAGE in nvdata MR FCODE Driver release Signed UEFI Driver 0x05180000 (for Win 8 Secure Boot) BIOS 4.31.00 HII 1.31.00 SCGCQ00293398 - Can not enable SSD caching in HII WebBIOS 4.0-59-e_48-Rel SCGCQ00295052 - Change BBU Mode description for Liberator batteries. PCLI 03.02.20 ROMENV 1.08 BootBlock 2.02.00.00-0001 v20.10.1-0107 Fixed Native configuration is no longer supported message in post Fixed Patrol Reads on SSD drives Fixed Implemented the limited band charging Fixed Megamon during Injecting errors to VD with 512e PDs on iMR controller Fixed Native configuration is no longer supported message in post Fixed CRC errors during TSOC communication Fixed iMR FW : Fail to read the header info from CFI Flash ROM during repeated system reboot. v20.10.1-0096 Fixed FW failes to create configuration and utilites fail to report the VD size after the reconstruction. Fixed BJW STC - Error message pop out in Hatteras HII when set to factory default. Fixed Megamon during import of FC from MR to iMR contoller v20.10.1-0077 Fixed CSET: BT1680: SATA workaround handles LBA incorrectly for 6-byte read CDB Fixed Bios prints extra lines for press Ctrl_G to enter bios when you have some configuration errors Fixed BT750 workaround code is not disabled in all the path Fixed TB BIOS : Overwrites invalid address and force system to fail the boot. v20.10.1-0051 1) Fix FW issue related to currentSSCSize. v20.10.1-0044 1) Fixed No event is generated when fan in enclosure fails 2) Fixed Medium error handling fixes for >2TB 3) Fixed PCR 235 Warning for High Error Counts 4) Fixed Add SGPIO for Medusa v20.10.1-0020 1) Fixed FW causes Fatal Error when HSP drive responded with Sense 0x02 for Write/Verify or TUR. 2) Fixed Machine Check with particular motherboard. 3) Fixed Provide the chip version/revision for MegaRAID controllers thru CmdTool2 4) Fixed After a complete and successfully recalibrate cycle the request to a relearn is still on 5) Fixed After FW downgrade eventlog is corrupted 6) Fixed Tape Device LTO-05 loads unexpectedly on SAS2108 and SAS2008 chip based MR adapters 7) Fixed Some LED are still not working according to OEM SPEC with latest NVDATA 8) Fixed intermittent RAID key authentication issue was occurring on boot up 9) Fixed PL version 05.00.28.00 check in 10) Fixed ESXi installation fails on RAID1/RAID0 cluster of two SSDs 11) Fixed Intermittent initialization failure (Fault code 0x01) SDRAM ReadEye calibration 12) Fixed sas address not programmed correctly for OEM Wasat boards 13) Fixed Copy back does not start in a case of revertible HSP 14) Fixed Field cant flash back from 10M08 to 10M04 successfully, requires Debugger 15) Fixed SFO 2108 ROMB reports a non-functional Local Disk as "Operable" 16) Fixed HSA0297 Command timeout happens in Electra + 600GB SAS HDD during the system power-on. 17) Fixed RAID-0 Volumes Disappeared After RAID Creation - intermittent 18) Fixed Disable VPD for specific SSVID 19) Added BBU AEN Change for 6G SAS controllers 20) Added ability to RESET expander from behind MegaSAS v20.7.1-0016 1) Fixed - After replacing a 3rd party expander card, all the virtual drives are gone if the system is rebooted 2) Fixed - Warning with RWC2 using Intel(R) RES2SV240 Expander Card with Intel MegaRAID cards 3) Fixed - Fix config loss due to lost device insertion post processing callback during NEM replacement 4) Fixed - Phy 0-3 should be rate limited to SAS 1 speeds for old chip sping. 5) Added - Change NVDATA settings (xml files) for iMR product 6) Added - Add new xml file for Inspur 7) Added - Add new ID for ASUS MR product 8) Added - Revise new iMR NVDATA 9) Added - Add New Customer IDs to iMR & MR 10) Added - Add CustomerIDs to 2108 MR (add a new xml file to 10M06 and later stream) v2.70.04-0862 1) Fixed Fw error during R50 9per per span rebuild. 2) Fixed >2TB : DATA TLB ERROR Exception is hit while creation of VD. 3) Fixed Change nvdata version stretagy to reflect corresponding train 4) Fixed Dummy defect to checkin the Liberator B4/ Falcon B2 downgrade scenarios 5) Fixed PL5 SAS_DISC_DS_MAX_ENCLOSURES_EXCEED 6) Fixed DC is hit on VIEWs after OCR during rebuild. 7) Fixed DI Issue : LDBBM entries are lost after REBOOT/OCR 8) Fixed 6919982 Activity LEDs are backwards 9) Fixed "DDF_ConfigReadPd" Error is shown in FW print on creating config OR during boot. 10) Fixed FW hit mon task after connect cable to enclosure. 11) Fixed Dummy defect to check in ieee changes 12) Fixed No OCR after controller halt for OEM specific Sentinel change 13) Fixed >2TB iMR: PR fails to detect medium errors 14) Fixed >2TB : PR fails to find any medium errors on all RAID levels. 15) Fixed Pl merge 05.00.07.00 16) Fixed Sentinel Testing:Copy pattern to R0, reboot and doing CC will result in MegaMon 17) Fixed All applications hangs when pdlist command is executed with 2TB SATA Drives. 18) Fixed DATA TLB ERROR Exception is hit while creation of VD on SATA PDs 19) Fixed Rebuild does not progress on a 2.2TB drive(restarts once it reaches 2%) 20) Fixed DI Issue : FW fails to populate valid LDBBM entries. 21) Fixed Sentinel testing: fw broke into MegaMon when test file is read (R0 and R1) 22) Fixed Sentinel file gets corrupted on VDs with non default stripe size 23) Fixed Dummy defect to check in B2 downgrade scenario changes for Falcon 24) Fixed Sentinel testing: Megamon hit at reboot after copying pattern to R0,R1,R5,R6(4 drive) 25) Fixed fw hits megamon on PD command timeout 26) Fixed iMR Drake Controller doesn't auto rebuild drives on McCave Backplane 27) Fixed DF365856 >2TB SATA drives are reported as only having 2TB capacity 28) Fixed FW went to mon_tsk() when running heavy IO's + Rebuilding 29) Fixed IO fail when running on 16 VDs. 30) Fixed iMR PL5 FW removes pds when failing redundant path 31) Fixed OEM changes for Sentinel 32) Fixed (RW LSIP200062530) Dummy defect to checkin the Liberator B4/ Falcon B2 downgrade scenarios 33) Fixed FW crashed when you Pull/Push SATA and SSD Drive with SAS Drive Present. 34) Fixed FW breaks to MonTask: line 2771 in file ../../dm/mpt2/mptcmd. 35) Fixed VD goes offline with command timeout on PDs in MP 36) Fixed FW breaks into MegaMon during boot if unconfigured SATA drives are present in a Shea enclosure 37) Fixed >2TB : DC is hit on R1/R5 VDs 38) Fixed > 2TB : Drive comes up as foreign even when there is no config. 39) Fixed DI Issue : CC/rebuild fails to detect the medium error. 40) Fixed Support for snapshot is missing in Special handling of Pattern. 41) Fixed Sentinel testing: Drive drop during cc after rebuild, and also during reconstruction 42) Fixed >2TB: iMR Drive comes up as foreign after clearing config and reboot 43) Fixed An un-configured PD comes up as configured after reboot. 44) Fixed Sentinel file (read) causes specific drive model to fail 45) Fixed >2TB-iMR-hotplug enclosure,debugger hit montask line 199 46) Fixed CC fails to detect Media errors for above 2TB VD size 47) Fixed >2TB : DI Issue : LDBBM entries are lost after REBOOT/OCR 48) Fixed >2TB : DC is hit on PRL 11 using >2TB drives ST33000650NS 49) Fixed Cascaded enclosures go missing when reconnecting enclosures to import foreign config. v2.60.04-0829 1) Fixed Fix DATA TLB exception while updating DDF 2) Fixed Check in PL 2.20 which has permenant fix for alignement exception v2.40.04-0787 1) Fixed Patrol Read wrongly detects medium error after full initialization. 2) Fixed Update MFC defaults in NVDATA 3) Fixed Change NVDATA to Enable exposeEnclosureDevices 4) Fixed change the slot mapping starting offset 5) Fixed Controller Properties Incorrectly Validated 6) Fixed HDD power save option is enabled by default for particular OEMs, and attempting to disable feature will not work *Third-party trademarks are the property of their respective owners.