This release note and the software that accompanies it are copyright (c) 2014, Intel Corporation or its suppliers, and may only be installed and used in accordance with the license that accompanies the software. This Software is furnished under license and may only be used or copied in accordance with the terms of that license. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. The Software is subject to change without notice, and should not be construed as a commitment by Intel Corporation or its suppliers to market, license, sell or support any product or technology. Unless otherwise provided for in the license under which this Software is provided, the Software is provided AS IS, with no warranties of any kind, express or implied. Except as expressly permitted by the Software license, neither Intel Corporation nor its suppliers assumes any responsibility or liability for any errors or inaccuracies that may appear herein. Except as expressly permitted by the Software license, no part of the Software may be reproduced, stored in a retrieval system, transmitted in any form, or distributed by any means without the express written consent of Intel Corporation. ========================== Supported RAID Controllers ========================== This download supports Intel(R) RAID controllers using MegaRAID SAS software stack (RS25SB008, RS25NB008), please verify that this utility has been tested with the RAID card you have chosen to use by checking the drivers web page for your controller at http://www.intel.com/support/. =================== Package Information =================== Flash package = v23.6.1-0028 ========== Attention! ========== Intel recommends to loading Factory Default setting after the firmware upgrade which will not affect data on any existing array. To do so: 1. Reboot the system and login to the RAID BIOS Console. 2. Select the controller and select 'Adapter Properties'->'Next' 3. Set the 'Set Factory Defaults' setting to 'Yes' and submit the change. 4. Reboot the system (the default settings are applied). 5. Re-configure to the desired settings in RAID Web Console2. ================== Known Restrictions ================== 1) This download does NOT support EFI v1.1 environment. Please use the EFI shell commander which will display the EFI version, to identify the EFI version. 2) When 2 or more VDs are created, VD cache settings must be the same. ======================= Contents on the package ======================= The following files are included in this zip: Name: Description: ir3_2208-HADAS_FWPKG-v23.6.1-0028_readme.txt This file 2208s11p.rom Firmware binary update.bat DOS firmware update batch file update.nsh UEFI firmware update batch file CmdTool2\DOS\* DOS update utility and support files CmdTool2\FreeBSD\* FreeBSD update utility and support files CmdTool2\Linux\* Linux update utility and support files CmdTool2\Solaris\* Solaris update utility and support files CmdTool2\UEFI\* UEFI update utility and support files CmdTool2\Windows\* Windows update utility and support files License_v2.pdf License Agreement COPYING.NEWLIB.txt License Agreement ========================== Installation instructions: ========================== UEFI (EFI 2.0) instructions for updating RAID Firmware: ----------------- 1. Download and extract all files to a local drive. 2. Boot the target system to EFI shell. 3. Change directory to the local drive and directory containing the flash update files and the firmware image file. 4. Type "update.nsh" or "efi\cmdtool2 -adpfwflash -f 2208s11p.rom -noverchk -aall" 5. Wait for the flash to complete. Do NOT reboot the system during the update. Windows and Linux instructions for updating RAID Firmware: ----------------- The firmware update may be run from Within Windows or Linux using the appropriate versions of CmdTool2. In Windows, unzip the utility into the same directory as the rom file by typing "cmdtool2 -adpfwflash -f 2208s11p.rom -aall". The Linux CmdTool2 by running the rpm and then calling the utility from /opt/MegaRAID/CmdTool2 as "./CmdTool2 -AdpFwFlash -f 2208s11p.rom -aall" DOS instructions for updating RAID Firmware: ----------------- 1. Download and extract all files to a local drive. 2. Boot the target system to DOS. 3. Change directory to the local drive and directory containing the flash update files and the firmware image file. 4. Type "update.bat" or "dos\cmdtool2 -adpfwflash -f 2208s11p.rom -aall" 5. Wait for the flash to complete. Do NOT reboot the system during the update. You can also use RAID Web Console 2 to update the RAID firmware. For more detail, please refer to the Intel(R) RAID Software User's Guide. ==================== Product Limitations: ==================== 1.SATA drives are not supported 2.SAS drives which do not support SCSI-3 persistent reservation 3.T10/DIF functionality is not supported 4.Dimmer Switch functionality is not supported 5.FDE/SED drives are not support 6.SPGIO sideband signal for enclosure management is not supported 7.Only supports SAS SSD for Cache Cade volumes 8.Supports Cachecade 1.0 only 9.4K Native and 512e HDD Sector HDDs are not supported 10.System/JBOD mode PDs are not supported 11.Drives that are direct-attached to the controller (not via expander device) is not supported 12.Cluster-Active Reconstruction operations (RAID Level Migration or Online Capacity Expansion) is not supported 13.Patrol Read operations that are in progress do not resume after failover 14.Virtual drive erase does not resume after failover 15.Full VD initialization does not resume after failover 16.Firmware-level node incompatibility details are not reported for non-premium features 17.Split-Brain detection logic can cause IO stop during slow failover (double fault) scenarios 18.maintainPdFailHistory is set to disabled/OFF mode by default. Workaround: In order to enable maintainPDFailHistory functionality, both nodes of cluster must be in the pre-boot environment and the setting enabled via pre-boot utility (WebBIOS). 19.Cannot update enclosure/ESM firmware with an active HA cluster (SCGCQ00413571). Workaround: Shutdown one node for the duration of the ESM firmware update process. Once the update has been completed, the previously shutdown node may be returned to an operational state. =========== Known Bugs: =========== 1.SCGCQ00451214 - Continue with the rebuild even after it loses the reservation results in the ddfPd.c (montask) 2.SCGCQ00497037 - Both SAS cables pulled from one node while IOs running in Linux caused all IOs to stop after LDs failed over to peer node -Workaround: Restart IO from client (surviving peer node will service IO) 3.SCGCQ00496951 - Hit IO stop on SQLStress test when pulling out power cord on each node -Workaround: See IO stop solution steps in Table 4 of Section 5.4 of the Syncro CS Solution User Guide =============== Package Details =============== 23.6.1-0028 (HADAS 1.1 Point release - Patch 9) WebBIOS 6.1-67-e_67-Rel Firmware 3.330.95-3530 SCGCQ00635730 (DFCT) - Firmware ASSERTS when one of the cable is pulled while running IO SCGCQ00665067 (DFCT) - Exclusive LD owner SAS address value is cleared when rebooting a system with pinned cache on one or more LDs SCGCQ00681149 (DFCT) - Handle drives with incorrect reservation conflict handling. SCGCQ00689891 (DFCT) - The spare configuration disappeared after power cycling the cluster SCGCQ00704634 (DFCT) - RAID configuration will be gone after few reboots. SCGCQ00678957 (CSET) - Data integrity check fails with local I/O's running on RAID1 (PRL11) VD during PD pull/push if VDs created with drive cache disabled. SCGCQ00686661 (CSET) - Cache Mirroring state failure when injecting uncorrectable Medium Errors & running shipped IO on RAID5 SCGCQ00703511 (CSET) - Firmware asserts on doing enclosure power cycle (with shipped IO). SCGCQ00704638 (CSET) - Rebuild did not start after a drive is removed. BIOS 5.43.00.2 UEFI_Driver 0x06000501 HII 04.00.01.01 WebBIOS 6.1-67-e_67-Rel ROMENV 1.08 PCLI 05.06.03 BootBlock 2.05.00.00-0009 NVDATA 2.1210.03-0116 BootBlockCommon 07.26.26.219 23.6.1-0027 (HADAS 1.1 Point release - Patch 8) Firmware 3.330.85-3409 SCGCQ00675339 - (Closed) - Cache Offload not happening on a Clean shutdown in certain cases SCGCQ00666040 - (Port_Complete) - Do not allow user to enable maintainPdFailHistory SCGCQ00656770 - (Port_Complete) - Start of Day peer discovery does not complete successfully when both controllers are rebooted at the same time. SCGCQ00664378 - (Port_Complete) - Cluster disks go offline and cluster roles fail when the controller on a node resets SCGCQ00656763 - (Port_Complete) - A Global Hotspare reversed right back to Global Hotspare after rebuilding kicked in BIOS 5.43.00.2 SCGCQ00621383 - (Port_Complete) - Add the logic to handle the Boot message till the controller state remains boot message pending UEFI_Driver 0x06000501 SCGCQ00478350 - (Closed) - there is debug message print out during system boot up SCGCQ00478693 - (Port_Complete) - Block IO tests from SCT IHV test suite failed SCGCQ00484071 - (Port_Complete) - Follow UEFI Spec on interpreting In and Out Transfer Length that upper layer sends SCGCQ00477829 - (Port_Complete) - 9240/9260/9270 UEFI driver issue with OEM platforms when user having 2TB or 4TB VD SCGCQ00484084 - (Port_Complete) - OEM platfrom has UEFI hang when SATA is connected SCGCQ00492584 - (Port_Complete) - UEFI System hang if controller FW is in fault state SCGCQ00492582 - (Port_Complete) - Uninstall HII CAP and Driver Health formset if platform calls Start again without calling GetHealthStatus HII 04.00.01.01 WebBIOS 6.1-67-e_67-Rel ROMENV 1.08 PCLI 05.06.03 BootBlock 2.05.00.00-0009 NVDATA 2.1210.03-0116 BootBlockCommon 07.26.26.219 Package - 23.6.1-0026 (HADAS 1.1 patch7) Firmware v3.330.75-3331 SCGCQ00530887 - Resolved a number of Persistent Reservation issues SCGCQ00557273 - Improved the performance of the LD Persistent Reservation SCGCQ00619441 - "All of the disks from your previous configuration are gone" warning message at boot time. SCGCQ00644485 - Firmware hits kill adapter when cables are pulled while IOs are running. SCGCQ00480260 - Enclosure fault LEDs are on following repeated failover of VDs SCGCQ00501820 - Shutdown of a node with an OFFLINE VD results in firmware crash SCGCQ00521372 - Reconstruction operation failed to resume after reboot SCGCQ00600858 - Drive in system does not become ready and causes the peer to see no good drives. SCGCQ00626651 - When the user power off and power on the master node, a boot message is displayed during POST SCGCQ00524510 - Global hostspare disappears during rebooting both nodes simultaneously SCGCQ00553023 - HDD status LED will be lit red after creating and deleting LD but the status is normal via MSM SCGCQ00620463 - Failover times out if there are more than 35 drives involved. SCGCQ00601934 - Firmware faults when running script to create Logical Drives SCGCQ00552755 - Incorrect variable type in MR Read/Modify/Write path SCGCQ00618661 - After SAS cable removal and replacement configured LDs did not show up in LINUX OS SCGCQ00565007 - Rebuild is not starting from the beginning after manual foreign import SCGCQ00518306 - Do not see copyback resume on the failover node SCGCQ00639066 - Global hotspare disappear if reboot both nodes SCGCQ00660422 - Allow Syncro to boot with SATA drives SCGCQ00549442 - Minor changes needed for handling persistent reservation RELEASE process more robustly SCGCQ00552364 - Remove Mirror Journal Assertion failure because of invalid targetId SCGCQ00552500 - RMW error on RAID5 while copyback during IO & Rebuild doesn't kick in after removing drive with GHS. SCGCQ00552546 - Stale mirror line causes assertion failure. SCGCQ00552605 - I/O failed when OCR after move group on 64VDs SCGCQ00553265 - Miscompare after copy back is finished. SCGCQ00558261 - HDD status LED will be lit red after creating and deleting LD but the status is normal via MSM SCGCQ00571309 - Copyback from hotspare fails to start automatically after completion of rebuild operation SCGCQ00574459 - Firmware crash at firmware load time after pinning cache on previous bootup. SCGCQ00594076 - Adding and modifying existing messages for cache debugging SCGCQ00594078 - Parity is not calculated properly for missing rebuild drive SCGCQ00620381 - Hitting firmware assert during foreign import SCGCQ00531388 - Cluster validation failed in disk arbitration SCGCQ00616228 - Raid configuration loss after reboot - PDs in POWERSAVE SCGCQ00573374 - When user power off the owner node, sometimes the RAID volume will rebuild automatically SCGCQ00577062 - A rebuild is occuring while command block is held. SCGCQ00593523 - There are write journal orphan entries when importing foreign configuration, thus resulting in firmware to halt SCGCQ00612156 - PMU error on controller 1 during failover testing SCGCQ00626724 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap. SCGCQ00656369 - Drives did not rebuild and become configured good after turning off and on the cascading enclosure while running I/O. SCGCQ00504024 - Enclosure fault LEDs are on following repeated failover of VDs SCGCQ00580429 - Reconstruction operation failed to resume after reboot - ( SCGCQ00571020) SCGCQ00618513 - Pinned Cache is not getting invalidated on recovery for R0/R1 LDs SCGCQ00620165 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset SCGCQ00559855 - All the HDD drive status change to "Foreign" after rebooting the owner node SCGCQ00572392 - Validate the requested blocks for SCSI VERIFY commands on RAID volumes SCGCQ00559856 - Improved the performance of the LD Persistent Reservation SCGCQ00612161 - DDF reads of restricted PD causes firmware to enter deadlock. SCGCQ00531386 - Validate disk failover test fails in cluster validation tests SCGCQ00552509 - Phase 1- Some VD's do not get transferred over/not seen after VD expansion and OCR SCGCQ00571304 - Firmware debugger kept rolling after forcing the active controller into the fault state SCGCQ00580385 - Data corruption after making VD's offline and power pull SCGCQ00549326 - While IO going on trigger OCR see VD with access blocked SCGCQ00571305 - Assertion failure during cache line mirror to dirty conversion SCGCQ00631654 - Data corruption found when pulling cables from the node which is owner of the logical drive BIOS 5.43.00 WebBIOS 6.1-67-e_67-Rel UEFI_Driver 0x06000500 HII 04.00.01.01 SCGCQ00527052 (DFCT) - HII Create VD- advance sees default as no share SCGCQ00482102 (CSET) - Typos in help content for profile VD for Write Policy SCGCQ00492573 (CSET) - Profile based VD creation path incorrectly showing protect VD/secure VD checkbox when user clicks on drive selection criteria SCGCQ00498664 (CSET) - HII cannot create a VD using unconfigured good drives as long as PD locate is set on the drives SCGCQ00524427 (CSET) - HII cannot assign partial space less than 1 GB SCGCQ00555334 (CSET) - To be in sync with other subtitles make all letters capital for "High Availability Properties" and add colon at the end SCGCQ00492576 (CSET) - Obtain the Physical Slot number from the PCI Bridge to which the Controller is connected. PCLI 05.06.03 BootBlockCommon 07.26.26.219 BootBlock 2.05.00.00-0009 NVDATA 2.1210.03-0116 ROMENV 1.08 Package - 23.6.1-0024 (HADAS 1.1 patch2) Firmware v3.330.55-3210 SCGCQ00619188 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap Package - 23.6.1-0020 (HADAS 1.1 patch) Firmware v3.330.25-3064 SCGCQ00524510 - Global hostspare disappears during rebooting both nodes simultaneously SCGCQ00530887 - Resolved a number of Persistent Reservation issues SCGCQ00557273 - Improved the performance of the LD Persistent Reservation SCGCQ00480260 - Enclosure fault LEDs are on following repeated failover of VDs SCGCQ00501820 - Shutdown of a node with an OFFLINE VD results in firmware crash SCGCQ00553023 - HDD status LED will be lit red after creating and deleting LD but the status is normal via MSM SCGCQ00552755 - Incorrect variable type in MR Read/Modify/Write path SCGCQ00565007 - Rebuild is not starting from the beginning after manual foreign import SCGCQ00518306 - Do not see copyback resume on the failover node SCGCQ00549442 - Minor changes needed for handling persistent reservation RELEASE process more robustly SCGCQ00552546 - Stale mirror line causes assertion failure. SCGCQ00553265 - Miscompare after copy back is finished. (SCGCQ00552646) SCGCQ00558261 - HDD status LED will be lit red after creating and deleting LD but the status is normal via MSM SCGCQ00574459 - Firmware crash at firmware load time after pinning cache on previous bootup. SCGCQ00594076 - Adding and modifying existing messages for cache debugging SCGCQ00594078 - Parity is not calculated properly for missing rebuild drive (SCGCQ00575728) SCGCQ00531388 - Cluster validation failed in disk arbitration SCGCQ00573374 - When user power off the owner node, sometimes the RAID volume will rebuild automatically SCGCQ00577062 - A rebuild is occuring while command block is held. SCGCQ00593523 - There are write journal orphan entries when importing foreign configuration, thus resulting in firmware to halt SCGCQ00504024 - Enclosure fault LEDs are on following repeated failover of VDs SCGCQ00559855 - All the HDD drive status change to "Foreign" after rebooting the owner node SCGCQ00572392 - Validate the requested blocks for SCSI VERIFY commands on RAID volumes SCGCQ00559856 - Improved the performance of the LD Persistent Reservation SCGCQ00531386 - Validate disk failover test fails in cluster validation tests SCGCQ00580385 - Data corruption after making VD's offline and power pull (SCGCQ00552474) BIOS v5.43.00 WebBIOS v6.1-67-e_67-Rel UEFI_Driver v0x06000500 HII v04.00.01.00 PCLI v05.06.03 NVDATA v2.1210.03-0116 BootBlockCommon v07.26.26.219 BootBlock v2.05.00.00-0009 FCODE v4.12.05.00 ROMENV v1.08 Package v23.6.1-0018 - (HADAS 1.1) Firmware 3.330.05-2793 SCGCQ00399334 - Disable adding PD FailHistory entries into DDF when maintain PD FailHistory is FALSE SCGCQ00471752 - Shared Raid5 virtual drive became foreign configuration when owner node was rebooted. SCGCQ00472265 - Cleanup Patrol Read debug prints SCGCQ00480316 - Backing out the changes associated to the original defect CQ 475243 because data corruption was found, and will be reworked using CQ 480315. SCGCQ00414639 - PL: Certain PhyGroup configurations result in fault 0x7600 SCGCQ00434111 - Firmware asserts when delete the reconstruction Logical drive (LD) SCGCQ00448301 - MSM log events do not show correct message to user SCGCQ00454941 - Insert removed pds with maintain PD failhistory enabled and still see PD rebuilding SCGCQ00466869 - Changing unconfigured bad drive to unconfigured good did not reflect on the peer node SCGCQ00437514 - Update bbu and hw\usb directories to the level of the MR 5.3 Generic Point Release 2 stream. SCGCQ00461797 - Firmware hits ASSERT when running I/O from client and move group every five minutes. SCGCQ00462466 - The failover is skipped and take the error path when doing single path failover. SCGCQ00464015 - Linux MSM owner node doesn't auto update when we initiate planned failover from megamon SCGCQ00473171 - Illegible character in boot message when entering safe mode SCGCQ00477167 - cache version increment is not working SCGCQ00478655 - Firmware hits kill adapter when the user issues online firmware update command to the controller SCGCQ00481763 - Firmware faults when Turn OFF/ON Enclosure SCGCQ00481766 - Unsupported SAS drive only show in one node SCGCQ00443406 - Fimware hits ASSERT when reboot peer node SCGCQ00461518 - Target mode error handling print improvements for debugging and minor bug fixes SCGCQ00470899 - Some configured drives were not imported during failover when shutting down a node. SCGCQ00472716 - In Linux one node can't boot back to OS after shutting down both nodes. SCGCQ00480306 - The receiving node (peer) found ACCESS BLOCK after cable pull and reconnect with IOs running on client SCGCQ00493602 - MegaRAID firmware hit fault code 0xd05 after failover and Turn OFF/ON enclosure SCGCQ00458702 - HA firmware fails to unregister a non-target MegaRAID initiator when it goes into safe mode SCGCQ00464506 - PD fail history entries get cleared when CRC errors occur SCGCQ00472805 - Unnecessary rebuild initiated during a Logical Drive(LD) Failover creating dummy foreign configurations. SCGCQ00482273 - With PD Fail History enabled, unconfigured bad drives that have been marked unconfigured good may be remarked unconfigured bad SCGCQ00485398 - Pinned cache reported only on one node after reboot (expected behavour is both nodes) SCGCQ00417694 - Syncro-CS controller cannot set disableHII to 0 using MFC command in megamon SCGCQ00436992 - In Linux - After initiating a Planned Failover from Debugger, found foreign configuration SCGCQ00440238 - HII Browser did not update after pull online drives SCGCQ00447877 - Firmware hits an ASSERT when internal utility is used to crash one node SCGCQ00449882 - Boot target Id is inconsistent across Nvram and Disk Data Format (DDF) SCGCQ00461497 - During the recovery of IO Shipped request the device driver is sending firmware a OCR(online controller reset) SCGCQ00464888 - Internal firmware error encountered if a virtual disk (VD) goes to offline state during failover SCGCQ00465556 - Firmware faults when updating enclosure firmware using StorCli . SCGCQ00468573 - Can't install OS RHEL6.4 x64b with a non-shared volume on SyncroCS SCGCQ00480315 - ACCESS BLOCK after a peer discovery generated planned failover due to cache version mismatch SCGCQ00399639 - Code Cleanup - Peer Arb not granted during Unplanned Failover SCGCQ00426927 - Data Miscompare found while running i/o overnight with degraded virtual drives SCGCQ00454106 - Write-policy of non-shared volume changes to write-through by failover SCGCQ00462385 - Firmware messages keep rolling when a node enters safe mode. SCGCQ00464018 - Pinned cache is reported when booting a server while the other server is performing reconstruction operations SCGCQ00480307 - Backing out the changes associated to the original defect CQ 470424 because data corruption was found, and will be reworked using CQ 480306. SCGCQ00484772 - I/O stop when pull out power cord of the owner node SCGCQ00398236 - Firmware faults when releasing peer block SCGCQ00413693 - Enclosure Hotplug not releasing drive reservations making drives to appear only on one node SCGCQ00425872 - Firmware faults when shutting down one node SCGCQ00425978 - Firmware faults when starting reconstruction SCGCQ00435817 - Firmware asserts when the disk is owned by peer SCGCQ00457774 - Misleading Fail/Offline Virtual Disk (VD) alert from MSM when reboot a node followed by logging into Windows SCGCQ00466131 - Inconsistent reporting of pinned cache SCGCQ00466221 - Global Hot Spare is marked as UNCONFIG_BAD when node reboots and gets failed over to peer SCGCQ00469069 - Foreign configuration present on the owner node even after clearing the foreign configuration on the peer node SCGCQ00477151 - Rebuilding did not resume where it left off on the peer when the (owner) failover happened SCGCQ00477239 - Firmware faults when reboot with unsupport drive and SATA drive SCGCQ00483905 - I/O's fail and VD becomes failed during planned failover of owner node w/ SMB I/O SCGCQ00493177 - HA: Fix compiler warnings SCGCQ00412114 - Medium Error Handling for Shipped I/Os SCGCQ00413632 - Syncro CS 1.1 Boot Device Selection SCGCQ00414605 - Performance Tuning - Implement a new Region Lock message for target mode Ios SCGCQ00278370 - Clean up of dead code SCGCQ00397077 - Cluster Active PD firmware flash SCGCQ00413633 - Maintain PD Fail History Across Nodes SCGCQ00439525 - Implemented SCSI3 PR Preempt and Abort Service Action SCGCQ00372093 - Refactor the IO shipping path SCGCQ00472732 - Change the Exclusive Virtual Disk(VD) behavior in the shutdown handling SCGCQ00297516 - Add a duplicate exception print to the TTY log to aid debug of host captures SCGCQ00397129 - Implement shutdown handling SCGCQ00436439 - Region Lock code sync up from PL code base 12.26.05.00 SCGCQ00383700 - Clear Pinned Cache On Both Nodes SCGCQ00407152 - Add Target Mode Error Injection capability. SCGCQ00447495 - PL binary 12.26.06.00 update SCGCQ00451109 - Debug variables for validating the shutdown handling process SCGCQ00410849 - MSM can not clear pinned cache list on the peer node. SCGCQ00411677 - Controller crashed during boot SCGCQ00421666 - If a rebuild is in paused state, and the Ld goes offline, the Pd remains in rebuild state. SCGCQ00421708 - Imported drive becomes unconfigured good when secure VD erase is running. SCGCQ00421749 - Memory test does not execute when performing FW diagnostics. SCGCQ00422021 - 3TB Hitachi HDD failed in immunity test (Electrostatic Noise test) SCGCQ00422025 - T-bolt firmware : makes unconfigured bad (foreign) to unconfigured bad on reboot. SCGCQ00424999 - Fault during a firmware failover SCGCQ00454856 - R/W buffer have different behavior between HBA and MegaRAID SCGCQ00411651 - found "Wait for Cache sync complete" kept coming when trying to reboot/shutdown it. Othenode is OFF SCGCQ00413286 - Hit MonTask: line 719 in file ../../raid/cachePreserve.c SCGCQ00421652 - Controller reports wrong elapsed time while reconstructing after OCR. SCGCQ00421757 - Set Drive State to JBOD in MR9266/MR2208 will cause Drive Fault LED light on SCGCQ00422022 - Patrol Read causes data integrity issue if the LDBBM is fulll SCGCQ00461456 - I/O fail while format partition. SCGCQ00467957 - Enhancement to decrease the duration of the slow failover functionality SCGCQ00478658 - On VMWare Data miscomparison found after 1st controller Failover SCGCQ00414648 - Assertion failure with no valid pool for LD being failed over SCGCQ00422036 - BIOS does not display accurate message when multiple enclosures are attached to the controller SCGCQ00422045 - A good SuperCap could be prematurely marked as failed. SCGCQ00424806 - Don't clear Recon LD PDs. SCGCQ00424882 - VD becomes WT with a good & new Super Cap on boot SCGCQ00435866 - Not able to boot operating system because the boot drive is in access block state SCGCQ00461454 - FW hitting Kill_Adapter mon_task after OCR is recovered/ reboot. SCGCQ00464977 - Out of resource conditions may lead to discovery non completion SCGCQ00481555 - Disconnect SCap during Shutdown/Hibernate only if pinned cache is not present SCGCQ00418683 - The reliability and error recovery of the SuperCap firmware was improved. SCGCQ00422019 - Subsequent drives are dropped when all drives in the stagger spin up drives fails on boot sequence. SCGCQ00422053 - A SuperCap could be shown as prematurely failed if a reboot occurred immediately after a learn cycle completed. SCGCQ00424856 - Serious performance issue found in firmware SCGCQ00413288 - Firmware crashed while booting with direct attached drives SCGCQ00421696 - When BGI is aborted and restarted, elapsed time is not reset SCGCQ00421719 - Port Hot spare disk does not adhere the disk cache policy (LSIP200229786). SCGCQ00422031 - Set RDM_FLAGS_FUA_REQ in immediate IO pah in rebuilding drive case. SCGCQ00435864 - Firmware crash during unplanned failover when there is pinned cache. SCGCQ00466797 - TFM error handling : Cache policy change for WB to WT if supercap is faulty SCGCQ00481560 - Write policy changed from WT to WB when the battery/Supercap is declared as bad SCGCQ00483981 - I/O stopped after one controller stuck in "invalid peerarb from devH xx sasAddr ffffffffffffffff" loop and 2nd Ctrl in montas SCGCQ00422024 - Hot Spare lost after FW update SCGCQ00423164 - Upon Online Controller Reset (OCR), Recon Ghost LD needs to be created before WJ processing SCGCQ00443244 - Firmware crash when pulling a drive from each span of a raid 50 logical drive SCGCQ00458624 - DDR3 init failure issue on OEM controller while performing cache offload. SCGCQ00466269 - Shutdown entered idle loop with pending virtual drive(VD) deletion SCGCQ00469561 - Firmware doesn't allow applications to create Virtual Drives (VDs) SCGCQ00411652 - Firmware Hit MonTask: line 1997 in file ../../raid/cache.c SCGCQ00413674 - CS1.0 FW hit SQLIO data corruption SCGCQ00415932 - MSM halt when import foreign config after enclosure off/on SCGCQ00421751 - Not able to flash both 9265-8i and 9285-8e card with 5.3 patch 1 firmware.However, it is ok on 9266-8i. SCGCQ00421763 - RAID Member disks state changed to (foreign) online and still can access. SCGCQ00422051 - VD Degraded after reconstruction of R5 SCGCQ00422055 - (multiple) Megacli64 error in deadlock state SCGCQ00423931 - If a correctable ECC error occurred during a cache offload, the CPU would crash, resulting in a data loss SCGCQ00424676 - Firmware faults on VD erase on Raid 1(R1) SCGCQ00442682 - Encountered firmware fatal error while reading Disk Data Format (DDF) record due to not holding SCSI-3 persistent device reservation on device SCGCQ00411676 - Firmware Crashed during node reboot SCGCQ00419379 - FW goes to montask at cache offload. SCGCQ00421707 - Firmware reports device initialization completion status to be greater than 100% at startup SCGCQ00421745 - Pulling cable when maintainpdfailhistory=1 create wrong state in arrays. SCGCQ00421750 - If a double bit error occurs during memory initialization on an OEM controller, GPIO 19 will now be asserted. SCGCQ00421753 - OCR is seen after setting to factory default and reboot SCGCQ00421759 - The SuperCap will now remain in the failed state when its capacitance falls below the minimum or its resistance exceeds the maximum SCGCQ00421762 - 2208 ROMB see 0 Capacitance SCGCQ00422032 - Controller does not come up while a PD Erase is in progress_Debug Firmware SCGCQ00422049 - Offline drive becomes automatically online during Raid Level Migration SCGCQ00450651 - 9260-8i(SAS2108) hitting OOB SRAT timeout for a long time causing OOB commands to fail SCGCQ00461430 - DDF read sections might fail. SCGCQ00467326 - System hang on boot when a global hot spare is configured SCGCQ00467327 - Failover takes more time than normal when node pull from Cib hardware SCGCQ00471848 - Firmware hits kill adapter when pulling out the blade while I/O is running from client on CiB system. SCGCQ00476251 - Firmware is hitting kill adapter on both servers when the two Sas cables are pulled from the LD owner node with I/O running from the client. BIOS 5.43.00 SCGCQ00408767 - OpROM not getting relocated to runtime segment if the segment address is 0xC0000 SCGCQ00395750 - BIOS build date field is empty and build date is displayed as BIOS build time in SLT. SCGCQ00397476 - BIOS: Provide scratch segment and populate info to assist Ctrl R to load latest host SCGCQ00403158 - Update OEM Sub System Device Ids and the corresponding BBS strings. SCGCQ00459907 - Boot Device Selection in multi boot configuratio WebBIOS 6.1-67-e_67-Rel SCGCQ00330068 - Creating a non shared VD become shared VD in WebBIOS. SCGCQ00365948 - HAMR: Not Able To See/Display The Last Drive On The WebBios SCGCQ00466265 - HA WEB BIOS give a blank screen when discard pinned cache from peer node SCGCQ00308396 - HAMR-- WEB BIOS Hang when Create Automatic Configuration With No Redundancy SCGCQ00319238 - HAMR WebBIOS release with newer load address. SCGCQ00350319 - HAMR: Wrong Enclosue ID Shows Between Node 1 & Node 2 SCGCQ00324174 - "Boot error handling" options are not correct in WebBIOS. SCGCQ00314460 - HAMR_Code_Port SCGCQ00308399 - HAMR WEB BIOS : The Share Virtual Drive is uncheck when Create Auto-Config With Redundancy Arrays SCGCQ00380877 - Revoking Set Boot Drive radio button from all the VDs which are not candidate boot VD. SCGCQ00435804 - WebBios Didn't Display The PinnedCacheList On all offlined virtual drives with preserved SCGCQ00322616 - HA-DAS: Applications need to handle the new LD_ACCESS_STATUS (MR_LD_ACCESS_STATUS_PEER_UNAVAILABLE) SCGCQ00322614 - HA-DAS: HA terminologies used in all the applications need to be modified SCGCQ00322613 - An appropriate error message should be prompted when the user assigns a DHSP to multiple arrays belong to different LDs SCGCQ00364498 - Add Support for OEM HA-DAS product SCGCQ00340795 - Application needs to check for HA-DAS feature support. SCGCQ00345326 - Not able to associate multiple VDs in a cache pool. SCGCQ00368009 - Wrong spanned drive group size is displayed by Web bios(Ctrl-H). SCGCQ00310305 - WebBIOS displays SSD association screen for Secured and Protected VDs (Virtual drive table is empty). SCGCQ00309608 - WebBIOS should not allow RLM for protected VDs with non-PI drives. SCGCQ00310292 - Remaining capacity is coming 0 from FW. SCGCQ00310293 - Battery Firmware vesion(MR_BBU_DESIGN_INFO.moduleVersion) is coming as Null SCGCQ00310296 - Preboot apps have to change load address change because of FW changes. SCGCQ00449148 - In WebBIOS, if BGI is suspended the vd progress info page shows it as CC progress until it is resumed. SCGCQ00310306 - WebBIOS does not show "Day" for Next learn cycle time in battery page. And issue with safe mode. SCGCQ00310294 - WebBIOS does not warn user before importing PI enabled VD on PI disabled controller. SCGCQ00310295 - WebBIOS reports incorrect number of foreign configs during "Scan Devices" UEFI_Driver 0x06000500 SCGCQ00378953 - HII not showing up + other enhancement for driver health formset SCGCQ00413986 - HII app doesnt appear when there is critical message and when platform uses SetOptions SCGCQ00408333 - UEFI: Critical boot message formatting issue SCGCQ00384884 - Customize health formset + few other issues SCGCQ00395190 - When trying to create an R6/R5, I am unable to create though there are 3 SAS unconfigured good avail SCGCQ00396051 - UEFI Driver should not display finite boot messages SCGCQ00408094 - OEM system with a critical message does not enter EFI preboot config utility SCGCQ00395996 - Parse Boot message and remove \r\n at the beginning and replace \n with \r in other parts SCGCQ00331573 - Remove dependency on deprecated Driver Configuration2 protocol from UEFI Driver HII 04.00.01.00 SCGCQ00431622 - Navigation issue from Enable Drive Security form SCGCQ00397100 - Add HA support to HII NVDATA 2.1210.03-0116 SCGCQ00472354 - Change default setting of maintainPdFailHistory SCGCQ00503607 - Change default setting of Maintain Physical Device (Pd) Fail History to 0 for all OEM controllers PCLI 05.06.03 BootBlock 2.05.00.00-0009 BootBlockCommon 07.26.26.219 ROMENV 1.08 Package v23.6.0-0086 - Initial release (HADAS 1.0) Firmware 3.170.05-2458 BIOS 5.41.00 HII 03.02.03.00 PCLI 05.06-03 WebBIOS 6.1-63-e_63-Rel NVDATA 2.1210.03-0112 BootBlock 2.05.00.00-0009 Common Bootblock 07.26.13.219 *Third-party trademarks are the property of their respective owners.