This release note and the software that accompanies it are copyright (c) 2015, Intel Corporation or its suppliers, and may only be installed and used in accordance with the license that accompanies the software. This Software is furnished under license and may only be used or copied in accordance with the terms of that license. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. The Software is subject to change without notice, and should not be construed as a commitment by Intel Corporation or its suppliers to market, license, sell or support any product or technology. Unless otherwise provided for in the license under which this Software is provided, the Software is provided AS IS, with no warranties of any kind, express or implied. Except as expressly permitted by the Software license, neither Intel Corporation nor its suppliers assumes any responsibility or liability for any errors or inaccuracies that may appear herein. Except as expressly permitted by the Software license, no part of the Software may be reproduced, stored in a retrieval system, transmitted in any form, or distributed by any means without the express written consent of Intel Corporation. ========================== Supported RAID Controllers ========================== This download supports Intel(R) RAID controllers using SAS software stack (RMS25PB080, RMS25PB040, RMT3PB080, RMS25PB080N, RMS25CB080, RMS25CB040, RMT3CB080, RMS25CB080N, RS25AB080, RS25SB008, RS25DB080, RS25NB008), please verify that this utility has been tested with the RAID card you have chosen to use by checking the drivers web page for your controller at http://support.intel.com. =================== Package Information =================== Flash package = v23.32.0-0017 ========== Attention! ========== Intel recommends to loading Factory Default setting after the firmware upgrade which will not affect data on any existing array. To do so: 1. Reboot the system and login to the RAID BIOS Console. 2. Select the controller and select 'Adapter Properties'->'Next' 3. Set the 'Set Factory Defaults' setting to 'Yes' and submit the change. 4. Reboot the system (the default settings are applied). 5. Re-configure to the desired settings in RAID Web Console2. ================== Known Restrictions ================== 1) This download does NOT support EFI v1.1 environment. Please use the EFI shell command ver" which will display the EFI version, to identify the EFI version. 2) When 2 or more VDs are created, VD cache settings must be the same. ======================= Contents on the package ======================= The following files are included in this zip: Name: Description: COPYING.NEWLIB.txt License Agreement ir3_2208SASHWR_FWPKG-v23.32.0-0017_readme.txt This file License_v2.pdf License Agreement MR512p.rom Firmware binary update.bat DOS firmware update batch file update.nsh UEFI firmware update batch file CmdTool2\DOS\* DOS update utility and support files CmdTool2\FreeBSD\* FreeBSD update utility and support files CmdTool2\Linux\* Linux update utility and support files CmdTool2\Solaris\* Solaris update utility and support files CmdTool2\UEFI\* UEFI update utility and support files CmdTool2\Windows\* Windows update utility and support files ========================== Installation instructions: ========================== UEFI (EFI 2.0) instructions for updating RAID Firmware: ----------------- 1. Download and extract all files to a local drive. 2. Boot the target system to EFI shell. 3. Change directory to the local drive and directory containing the flash update files and the firmware image file. 4. Type "update.nsh" or "efi\cmdtool2 -adpfwflash -f MR511.rom -noverchk -aall" 5. Wait for the flash to complete. Do NOT reboot the system during the update. Windows and Linux instructions for updating RAID Firmware: ----------------- The firmware update may be run from Within Windows or Linux using the appropriate versions of CmdTool2. In Windows, unzip the utility into the same directory as the rom file by typing "cmdtool2 -adpfwflash -f MR511.rom -aall". The Linux CmdTool2 by running the rpm and then calling the utility from /opt/MegaRAID/CmdTool2 as "./CmdTool2 -AdpFwFlash -f MR511.rom -aall" DOS instructions for updating RAID Firmware: ----------------- 1. Download and extract all files to a local drive. 2. Boot the target system to DOS. 3. Change directory to the local drive and directory containing the flash update files and the firmware image file. 4. Type "update.bat" or "dos\cmdtool2 -adpfwflash -f MR511.rom -aall" 5. Wait for the flash to complete. Do NOT reboot the system during the update. You can also use RAID Web Console 2 to update the RAID firmware. For more detail, please refer to the Intel(R) RAID Software User's Guide. =============== Package Details =============== 23.32.0-0017 (MR 5.12 Patch) Firmware 3.440.25-4055 SCGCQ00814833 - (Closed) - Gen2 - Negotiated link speed for a 6G drive when connected to Cobra Expander ( Databolt enabled phy's ) comes as 12G SCGCQ00807700 - (Closed) - Condado Beach- FW pkg 23.22.0-0017 and later initialize drives ~50% slower SCGCQ00815663 - (Closed) - Updating comments in Tfm Connect. SCGCQ00806817 - (Closed) - MR 5.12 appears to be incompatible with early production SuperCap units sold SCGCQ00787503 - (Port_Complete) - Updated Gemini version in MR firmware stream. SCGCQ00791746 - (Port_Complete) - Seagate 12G ST800FM0013 Drive Speed shows as "UNKNOWN" in MSM with 9240/9260/9270 NVDATA 2.1409.03-0139 SCGCQ00802595 - (Closed) - New LDBBM values is not loaded on firmware upgrade. WebBIOS 6.1-73-e_73-Rel ROMENV 1.08 PCLI 05.07.00 BootBlock 2.05.00.00-0010 BootBlockCommon 07.26.26.219 UEFI_Driver 0x06090700 (SIGNED) Hii v03.10.09.00 (SIGNED) FCODE 4.16.08.00 BIOS 5.48.04.0 23.32.0-0009 (MR5.12) Firmware 3.440.05-3712 SCGCQ00701810 - (Closed) - Update Gas Guage Safety Status register bit positions SCGCQ00712268 - (Closed) - Internal development defect to correct Module version validation logic for Gas Gauge firmware update SCGCQ00729591 - (Closed) - Preventing PatrolRead from correcting the same error LBA in loop SCGCQ00730691 - (Closed) - The cache policy of Virtual Drives(VDs) do not change to Write-Through(WT) if FAULT is asserted and there is no indication in BQ33100 Safety Status register. SCGCQ00713438 - (Closed) - FW doesn't do an Online Firmware Update (OFU) after a successful Gas Gauge firmware update . SCGCQ00726689 - (Closed) - Patrol Read operation does not resume after a reboot when using the HII application. SCGCQ00735931 - (Closed) - Device Discovery does not complete in the case when Test Unit Read (TUR) command fails for 2 drives. SCGCQ00721106 - (Closed) - Foreign Import fail after controller exchange SCGCQ00723334 - (Closed) - FW reports a partially incorrect message in the case when 5 SuperCap learns retries fail. SCGCQ00735634 - (Resolved) - Drives change to "foreign" state when FW is downgraded from MR 5.11 to MR 5.6/5.7/5.8/5.9 SCGCQ00694585 - (Closed) - MR controller stops posting with message that controller as base port not responding when you have 238 PD's spun down. SCGCQ00703521 - (Closed) - When learn fails to start, FW retries 5 more times before SuperCap is reported bad SCGCQ00707882 - (Closed) - Performing reboot immediately after updating the Gas Gauge (before learn completes) results in the FW reporting an update error on every subsequent boot. SCGCQ00715168 - (Closed) - Flashing wrong Gas Gauge image (or any bad image) will force VDs to WT(Write Through) and fail and there is no path back to WB other than rebooting SCGCQ00726641 - (Closed) - During POST message overlaps with another line. SCGCQ00667469 - (Closed) - Firmware crash is seen while trying to import VDs when there is preserved pinned cache. SCGCQ00692169 - (Closed) - Code Review fixes for an Enhancement Request SCGCQ00730541 - (Closed) - Flashing wrong Gas Gauge FW will succeed if flashed after good Gas Gauge FW is flashed and before the learn starts SCGCQ00730700 - (Closed) - Few un-acceptable prints in serial log. SCGCQ00679094 - (Closed) - Change SuperCap auto learn cycle period to 27 days and 22 hours. SCGCQ00649843 - (Closed) - Issue a complete Gas Gauge reset on every boot SCGCQ00676800 - (Closed) - Implemented Gas gauge FW update functionality . SCGCQ00679095 - (Implemented) - Reduce the monitoring time of CL (Capacitor Learning) flag in BQ33100 Operation Status register to 5Sec when a learn command is issued. SCGCQ00671027 - (Closed) - When supercap learn is pending (overdue) at boot, exposure time in WB mode is seen for up to 1 minute 5 seconds. SCGCQ00712210 - (Port_Complete) - Preventing a specific supercap error message being printed in term log SCGCQ00725140 - (Port_Complete) - Extend firmware support for the new SuperCap revisions SCGCQ00734402 - (Port_Complete) - Few un-acceptable prints in serial log. SCGCQ00734409 - (Port_Complete) - Foreign Import fail after controller exchange SCGCQ00741846 - (Port_Complete) - Drives change to "foreign" state when FW is downgraded from MR 5.11 to MR 5.6/5.7/5.8/5.9 SCGCQ00709619 - (Port_Complete) - Machine Check exception occurs during cache offload SCGCQ00712170 - (Port_Complete) - Prevent changing unconfigured drives to JBOD in MR SCGCQ00733106 - (Port_Complete) - During the AC cycle test via SAS2208 MR card with TMMA, it will halt on cached data was lost error SCGCQ00733107 - (Port_Complete) - During the AC cycle test via SAS2208 MR card with TMMA, it will halt on cached data was lost error SCGCQ00741723 - (Port_Complete) - Preventing PatrolRead from correcting the same error LBA in loop SCGCQ00741771 - (Port_Complete) - Adding a check in firmware to validate incoming configuration structure SCGCQ00685816 - (Port_Complete) - Potential data integrity issue after media error correction SCGCQ00685958 - (Port_Complete) - SSD causes system to hang at POST SCGCQ00688176 - (Port_Not_Required) - Preventing controller reset after running several hours with ASPM(Active State Power Management) enabled SCGCQ00688177 - (Port_Complete) - Preventing VD read related cache setting changes when enabling write cache setting from OS SCGCQ00725141 - (Port_Complete) - Extend firmware support for the new SuperCap revisions BIOS 5.48.04.0 SCGCQ00720411 - (Closed) - OpROM 240VD: Not able to boot to OS from the VD whose target ID is greater than 128 SCGCQ00455591 - (Closed) - Memory access issue for Mercury when loading Ctrl R SCGCQ00693494 - (Closed) - setting deviceExposure greater than or eaual to 128 will show wrong VD handled by bios SCGCQ00455597 - (Closed) - Memory allocation: Allocate only two 64k SCGCQ00736737 - (Port_Complete) - xprintf display issue when FW reports percentage for device scan SCGCQ00709995 - (Port_Complete) - OEM wants the battery status text in BIOS to change from "missing" to "N/A" for iMR solutions. WebBIOS 6.1-71-e_71-Rel NVDATA 2.1409.03-0137 Various changes for different OEMs. UEFI_Driver 0x06090700 (SIGNED) SCGCQ00691044 - (Closed) - Code refactor effort: Hii Image buffer clean-up SCGCQ00688789 - (Closed) - DHP: Remove default value from numeric primitive that is present under suppressif SCGCQ00732773 - (Closed) - UEFI Driver: If the platform contains UEFI Spec Rev < than 2.3.0, then don't HII SCGCQ00756810 - (Closed) - PKG 9 HII form/When you have a a critical message such as missing VDs, after select "C" , it will show an assert SCGCQ00726723 - (Closed) - Ext/SCSI PassThru: UEFI Driver not filling direction flag correctly for Read SCGCQ00696656 - (Closed) - Update Mbox value for 240VD Support SCGCQ00650086 - (Implemented) - UEFI Driver UDK2010 complaince SCGCQ00688987 - (Port_Complete) - Don't let user boot to OS until user discards dirty cache SCGCQ00726756 - (Port_Complete) - Implement password EFI_IFR_FLAG_CALLBACK bit requirement from UEFI spec 2.4 Errata B SCGCQ00693159 - (Port_Complete) - Return health status failed if we have returned device error from Start() SCGCQ00726831 - (Port_Complete) - Safe guard: Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status SCGCQ00736761 - (Port_Complete) - Return health status failed if we have returned device error from Start() SCGCQ00756861 - (Port_Complete) - ControllerInfo[CtrlIndex].ControllerHandle got initialized incorrectly or too early SCGCQ00695249 - (Port_Complete) - Safe guard: Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status SCGCQ00716623 - (Port_Complete) - For OEM change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00726520 - (Port_Complete) - For OEM dont free the host memory during disconnect/unload process SCGCQ00726727 - (Port_Complete) - Ext/SCSI PassThru: UEFI Driver not filling direction flag correctly for Read SCGCQ00726830 - (Port_Complete) - DHP: Remove default value from numeric primitive that is present under suppressif SCGCQ00688988 - (Port_Complete) - Don't let user boot to OS until user discards dirty cache SCGCQ00716622 - (Port_Complete) - For OEM dont free the host memory during disconnect/unload process SCGCQ00725109 - (Port_Complete) - For OEM change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00726828 - (Port_Complete) - Code refactor effort: Hii Image buffer clean-up Hii v03.10.09.00 (SIGNED) SCGCQ00689437 - (Closed) - Schedule consistency check gives an error message on Apply changes SCGCQ00692849 - (Closed) - When Controller is in Safe Mode don't remove UCM formset SCGCQ00696506 - (Closed) - Grammaical errors in HII warning message during FW Flash. SCGCQ00691938 - (Closed) - HII: Return device error when MR_DCMD_CTRL_PROPERTIES_SET fails. SCGCQ00700304 - (Closed) - MR_240VD:System fails to boot into SETUP[F2] and displays blank screen with 160 and 240 VDs SCGCQ00716628 - (Closed) - To Handle Code collab review Defect for SCGCQ00700199 SCGCQ00700199 - (Closed) - After selcting Discard pinned Cache from Controller Management, Form will be taken to Cache and Memory after success. SCGCQ00702200 - (Closed) - Firmware Update feature fails to update firmware in HII SCGCQ00709543 - (Closed) - gHiiDriver.ExtLDSupport should be Filled with appropriate value before it's used SCGCQ00702196 - (Closed) - Asserts seen before loading HII SCGCQ00704309 - (Closed) - HII: Question value mismatch message seen in Enclosure Management screen. SCGCQ00714530 - (Closed) - HII: Firmware Update - On selecting empty folder, hang is seen. SCGCQ00731567 - (Closed) - use hwPresent.memory to determine iMR SCGCQ00706817 - (Closed) - MR_240VD: Virtual Drive properties[Read/Write/IO Policy] gets changed after VD creation from HII SCGCQ00710064 - (Closed) - Handline code collaborator Defect for SCGCQ00709543 SCGCQ00716636 - (Closed) - Incomplete SAS Address SCGCQ00705577 - (Closed) - Unable to select the second enlcosure when multiple enclosures are connected to a controller . SCGCQ00723184 - (Closed) - Capacity Allocation in drive group properties is inappropriate SCGCQ00730496 - (Closed) - MR: HII gives the option to set -head of queue for raid 0 SCGCQ00742103 - (Closed) - Remove Head Of Queue rebuild feature SCGCQ00704216 - (Closed) - HII hangs on selecting "View Drive Group Properties" SCGCQ00734447 - (Closed) - Patrol read prop page gives an error message on Apply changes SCGCQ00642228 - (Implemented) - Implement Head of Queue drive rebuild for MegaRAID controllers SCGCQ00650085 - (Implemented) - HEFU HII UDK2010 complaince SCGCQ00689070 - (Closed) - MR 6.2- Negative test HII browser- Mixing unsupported drives message needs update SCGCQ00664753 - (Closed) - Ability to enable/disable JBOD mode in HII & CTRL-R SCGCQ00656614 - (Closed) - Add ability to take a VD offline, bring back VD online SCGCQ00688454 - (Implemented) - HEFU HII UDK2010 complaince SCGCQ00695063 - (Port_Complete) - Call UninstallStoreLib when we call StopControllerHiiImpl function SCGCQ00695068 - (Port_Complete) - In HII Create VD option is enabled when resconstruction is in progress (on partial VD) SCGCQ00695072 - (Port_Complete) - H730P- Not showing PD to assign as DHS to R50/ R60 VD if PD is of lesser size than largest PD in V SCGCQ00695223 - (Port_Complete) - Contents of few help messages are improper SCGCQ00728678 - (Port_Complete) - OEM UEFI creating a new VD in a "hole" in the drive group free space, hangs when viewing drive group properties SCGCQ00756855 - (Port_Complete) - Chk the err status for HL_Get_PD_List() and HL_Get_PD_Info in UF002_PrepareData() + check Driver handle if index is valid ROMENV 1.08 PCLI 05.07.00 BootBlock 2.05.00.00-0010 BootBlockCommon 07.26.26.219 FCODE 4.16.08.00 23.29.0-0016 (MR 5.11 Patch) Firmware 3.410.35-3698 SCGCQ00729591 - (Closed) - Preventing PatrolRead from correcting the same error LBA in loop SCGCQ00721106 - (Closed) - Foreign Import fail after controller exchange SCGCQ00735634 - (Resolved) - Drives change to "foreign" state when FW is downgraded from MR 5.11 to MR 5.6/5.7/5.8/5.9 SCGCQ00730700 - (Closed) - Few un-acceptable prints in serial log. SCGCQ00725140 - (Port_Complete) - Extend firmware support for the new SuperCap revisions SCGCQ00733106 - (Port_Complete) - During the AC cycle test via SAS2208 MR card with TMMA, it will halt on cached data was lost error SCGCQ00625524 - (Closed) - When we attempt to retrieve iMR Thunderbolt controller firmware logs using an application, we see some lines that are wrapped without starting on a new line. SCGCQ00628096 - (Closed) - Internal Development team defect to fix build issues related to 240 Logical Drive API changes. SCGCQ00642214 - (Closed) - Improve the Jetstress test performance. SCGCQ00647519 - (Closed) - At boot up, if a learn is required or a learn is in progress, do not wait for the SuperCap to charge. SCGCQ00649854 - (Closed) - Limit the number of retries when learn fails to start after firmware issues the learn command. SCGCQ00660171 - (Closed) - Increasing SuperCap temperature above thresholds showed no Asynchronous Event Notification (AEN) or transition of Cache Policy to Write Through (WT) SCGCQ00665853 - (Closed) - Cannot import foreign configuration. SCGCQ00681334 - (Closed) - Foreign configuration import failure for spanned array with pinned cache SCGCQ00698155 - (Closed) - Machine Check exception occurs during cache offload SCGCQ00637696 - (Closed) - Montask issue in performance test. SCGCQ00644626 - (Closed) - Increase the SuperCap learn time out value for 2GB TMM-B solution. SCGCQ00690086 - (Closed) - Foreign configuration import failure when Virtual drives (VD) with pinned cache are present SCGCQ00658701 - (Closed) - Firmware enables Dimmer Switch (DS3) Power Save Options. SCGCQ00604562 - (Closed) - Requirement to implement 512e logical drives in Tbolt. SCGCQ00634798 - (Closed) - Enable FastPath for all LSI Controllers SCGCQ00649836 - (Closed) - If cache offload happens during a relearn, then the Firmware will halt at next boot for the learn completion. SCGCQ00598902 - (Closed) - Add better debugging functionality for Alarm related field issues SCGCQ00649837 - (Closed) - Start a learn even if the SuperCap is not completely charged. SCGCQ00653995 - (Closed) - Change the cache policy of Virtual Drives(VDs) to Write Through(WT) if SuperCap temperature goes above 60 degree Celsius. SCGCQ00680070 - (Closed) - Preventing controller reset after running several hours with ASPM(Active State Power Management) enabled SCGCQ00604567 - (Closed) - Display the Command Descriptor Block(CDB) for timed out commands. SCGCQ00655345 - (Port_Complete) - RAID Ctrl. non-staggered spin-up after power saving - spin down SCGCQ00604588 - (Port_Complete) - To Disable the logging of event MR_EVT_PD_EMERGENCY_SPARE_COMMISSIONED_REMINDER SCGCQ00618569 - (Port_Complete) - HDD resume failed during dimmer switch test method. SCGCQ00619852 - (Port_Complete) - System crashes and OS boot issues with 2008 R2 based on 9280-16i4e controllers after one drive is failing in a RAID 5. SCGCQ00636774 - (Port_Complete) - IO freeze on R5 while running host IO with BGI SCGCQ00637534 - (Port_Complete) - Running Storcli /C0/CV show or (show all) starts a relearn on supercap issue SCGCQ00642963 - (Port_Complete) - Mechanism to override NVDATA Drive Activity LED setting SCGCQ00646311 - (Port_Complete) - Consistency Check media error handling is incorrect and causes data integrity issue SCGCQ00646628 - (Port_Complete) - Fix for Infinite retries of command for a particular sense code SCGCQ00651315 - (Port_Complete) - Change when checking if copyback can be done on a PD in a PRL11 SCGCQ00670882 - (Port_Complete) - Patrol read is in progress even after issuing stop patrol read command through App SCGCQ00664995 - (Port_Complete) - At boot up, if a learn is required or a learn is in progress, do not wait for the SuperCap to charge. SCGCQ00604485 - (Port_Complete) - For a particular OEM, size of some 4TB drives is reported as zero SCGCQ00628212 - (Port_Complete) - correct when copyback (replace) for R11 can be done. SCGCQ00635737 - (Port_Complete) - Enable FastPath for all LSI Controllers SCGCQ00635754 - (Port_Complete) - SMART poll needs to issue log sense with page control set to current/ cummulative value SCGCQ00646312 - (Port_Complete) - Consistency Check media error handling is incorrect and causes data integrity issue SCGCQ00668555 - (Port_Complete) - Firmware breaks into montask if you boot with pinned cache SCGCQ00635749 - (Port_Complete) - HDD resume failed during dimmer switch test method. SCGCQ00643769 - (Port_Complete) - Mechanism to override NVDATA Drive Activity LED setting SCGCQ00646299 - (Port_Complete) - Cannot recover data from a recoverable media error after Patrol Read encounters recovery failure for RAID-1 SCGCQ00646300 - (Port_Complete) - Cannot recover data from a recoverable media error after Patrol Read encounters recovery failure for RAID-1 SCGCQ00649894 - (Port_Complete) - Getting Question Value mismatch when entering Controller management screen in HII SCGCQ00652191 - (Port_Complete) - CacheCade data loss after reboot SCGCQ00652257 - (Port_Complete) - CacheCade data loss after reboot SCGCQ00503256 - (Port_Not_Required) - Montask occurs when running host i/o and parallel OOB command SCGCQ00598400 - (Port_Complete) - For a particular OEM, size of some 4TB drives is reported as zero SCGCQ00692239 - (Port_Complete) - Improve the Jetstress test performance. SCGCQ00664994 - (Port_Complete) - Increase the SuperCap learn time out value for 2GB TMM-B solution. SCGCQ00675292 - (Port_Complete) - Battery/ Memory Problems are detected and cache offload does not happen with a 2GB Memory module/ SuperCap design. SCGCQ00675291 - (Port_Complete) - Battery/ Memory Problems are detected and cache offload does not happen with a 2GB Memory module/ SuperCap design. SCGCQ00668586 - (Port_Complete) - MR 6.4:Patrol read is in progress even after issueing stop patrol read command through App BIOS 5.47.05.0 SCGCQ00626821 - (Closed) - 240VD Support: In Post Restrict to 64 VD only SCGCQ00629987 - (Closed) - With more than 64 VD's in the configuration, number of Virtual Drives handled by BIOS message is not shown in the POST. SCGCQ00659974 - (Closed) - OpROM - If there is boot message, BIOS won't detect > 64 VDs SCGCQ00662761 - (Closed) - Display Warning Message when Preboot Configuration Utility are Disabled and User tries to lunch it SCGCQ00653048 - (Closed) - AutoSelectBootLd is not working if user has OS in VD > 64 SCGCQ00632011 - (Closed) - Firmware enters faults state after a reboot on flashing firmware with IO in progress. SCGCQ00682646 - (Closed) - Display the first 64 VDs in the POST (in the same sequence we get it from FW) SCGCQ00690943 - (Implemented) - OEM wants the battery status text in BIOS to change from "missing" to "N/A" for iMR solutions. SCGCQ00626602 - (Implemented) - VT-d/IOMMU support for iMR - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00621895 - (Closed) - WebBIOS of MR card hangs due to bios control mis-direct in OEM boards SCGCQ00550388 - (Closed) - Write Caching HBA, JBOD/R0 supported TB controller with 240 SystemPD/LD support SCGCQ00644761 - (Port_Complete) - VT-d/IOMMU support for iMR - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00645908 - (Port_Complete) - Firmware enters faults state after a reboot on flashing firmware with IO in progress. SCGCQ00679070 - (Port_Complete) - Display Warning Message when Preboot Configuration Utility are Disabled and User tries to lunch it SCGCQ00697504 - (Port_Complete) - setting deviceExposure greater than or eaual to 128 will show wrong VD handled by bios UEFI_Driver 0x06080502 (SIGNED) SCGCQ00726756 - (Port_Complete) - Implement password EFI_IFR_FLAG_CALLBACK bit requirement from UEFI spec 2.4 Errata B SCGCQ00693159 - (Port_Complete) - Return health status failed if we have returned device error from Start() SCGCQ00726831 - (Port_Complete) - Safe guard: Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status SCGCQ00726520 - (Port_Complete) - For OEM dont free the host memory during disconnect/unload process SCGCQ00726727 - (Port_Complete) - Ext/SCSI PassThru: UEFI Driver not filling direction flag correctly for Read SCGCQ00726830 - (Port_Complete) - DHP: Remove default value from numeric primitive that is present under suppressif SCGCQ00688988 - (Port_Complete) - Don't let user boot to OS until user discards dirty cache SCGCQ00725109 - (Port_Complete) - For OEM change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00726828 - (Port_Complete) - Code refactor effort: Hii Image buffer clean-up SCGCQ00638308 - (Closed) - FMP GetImageInfo could result in stack corruption - Code Review Defect ID D26304 SCGCQ00628627 - (Closed) - UEFI Driver- has debug print statements during POST SCGCQ00628310 - (Closed) - Install FMP on Controller Handle at Start() and the exception SCGCQ00550389 - (Closed) - Write Caching HBA, JBOD/R0 supported TB controller with 240 SystemPD/LD support SCGCQ00626601 - (Implemented) - VT-d/IOMMU support for iMR - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00688791 - (Port_Complete) - Remove default value from numeric primitive that is present under suppressif SCGCQ00635878 - (Port_Complete) - has debug print statements during POST SCGCQ00696371 - (Port_Complete) - For OEM change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00698249 - (Port_Complete) - Don't let user boot to OS until user discards dirty cache SCGCQ00698254 - (Port_Complete) - Code refactor effort: Hii Image buffer clean-up SCGCQ00677776 - (Port_Complete) - Initilize the buffer that we allocate to load HII and return EFI_OUT_OF_RESOURCES if allocation fails SCGCQ00696543 - (Port_Complete) - VT-d/IOMMU support for iMR - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00698238 - (Port_Complete) - Do not go to WebBIOS due to a bad health status when WebBIOS is disabled in NVDATA. SCGCQ00679073 - (Port_Complete) - Do not go to WebBIOS due to a bad health status when WebBIOS is disabled in NVDATA. SCGCQ00699147 - (Port_Complete) - For OEM dont free the host memory during disconnect/unload process SCGCQ00644508 - (Port_Complete) - CPU EXCEPTION ERROR During CSIOR Stage SCGCQ00644509 - (Port_Complete) - CPU EXCEPTION ERROR During CSIOR Stage SCGCQ00644856 - (Port_Complete) - Install FMP on Controller Handle at Start() and the exception SCGCQ00661595 - (Port_Complete) - ATA Pass thru: Timeout is not passed correctly to FW SCGCQ00644859 - (Port_Complete) - FMP GetImageInfo could result in stack corruption - Code Review Defect ID D26304 SCGCQ00658168 - (Port_Complete) - ATA Pass thru: Timeout is not passed correctly to FW SCGCQ00698248 - (Port_Complete) - Initilize the buffer that we allocate to load HII and return EFI_OUT_OF_RESOURCES if allocation fails SCGCQ00698250 - (Port_Complete) - Safe guard: Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status Hii v03.09.06.00 (SIGNED) SCGCQ00625438 - (Closed) - Minor Typos and consistency issues in HEFU HII help text SCGCQ00633320 - (Closed) - Handling code collaborator Defects: SCGCQ00573222 and SCGCQ00568814 SCGCQ00602492 - (Closed) - HII 240 VD: HII fails to list the foreign configuration SCGCQ00658674 - (Closed) - Hii - Restrict the user from creating the 65th VD. SCGCQ00630532 - (Closed) - Consistency Check Start - remove mm/dd/yyyy from the string as the format is out of control of LSI SCGCQ00678695 - (Closed) - Change the Step Value to 0 for all numeric to make sure for free edit instead of Incrementing and decrementing using +/- SCGCQ00624890 - (Closed) - Handling Code Collaborator Defect: SCGCQ00573222 SCGCQ00679861 - (Closed) - Not able to create VD with 4k drives on OEM server. SCGCQ00645532 - (Closed) - Update the string for help SCGCQ00640534 - (Closed) - HII is showing RAID6 and RAID5 levels while creating VD when we have 2 512n drives and 1 4k Drives SCGCQ00678603 - (Closed) - HII does not display power state of a PD SCGCQ00637539 - (Closed) - Remove FMP installed on the controller handle in HII SCGCQ00627778 - (Closed) - Address review comments SCGCQ00672925 - (Closed) - Unable to set spinup drive count in HII SCGCQ00550390 - (Closed) - Write Caching HBA, JBOD/R0 supported TB controller with 240 SystemPD/LD support SCGCQ00626605 - (Closed) - Clone SCGCQ00556243 into the mainline SCGCQ00620259 - (Closed) - Port 240VD change to Tbolt SCGCQ00441334 SCGCQ00634019 - (Closed) - Change the default Setting of Disk Cahce Policy from Unchanged to Disable. SCGCQ00626591 - (Closed) - Add Mirror Join functionality - PR SCGCQ00521537 SCGCQ00626585 - (Closed) - Requirement for 512e implementation changes - PR SCGCQ00425778 SCGCQ00642232 - (Closed) - Ability to enable/disable JBOD mode in HII SCGCQ00621285 - (Closed) - Change the wording in HII from Check Consistency to Make data consistent SCGCQ00652171 - (Port_Complete) - HII is gave a option to start reconstruction from any degraded RAID level to RAID 0. SCGCQ00677103 - (Port_Complete) - Detail Drives info shows incorrectly in BIOS - unknown characters appearing SCGCQ00679042 - (Port_Complete) - Enhance strings for Locked foreign config import feature SCGCQ00644857 - (Port_Complete) - Remove FMP installed on the controller handle in HII SCGCQ00644858 - (Port_Complete) - RSOD during POST after enabling SecureBoot with OEM controller installed SCGCQ00661685 - (Port_Complete) - HII reports wrong data under 'Eligible JBOD Drives for conversion' while converting JBOD to UG SCGCQ00698646 - (Port_Complete) - Unable to set spinup drive count in HII SCGCQ00698664 - (Port_Complete) - Not showing PD to assign as DHS to R50/ R60 VD if PD is of lesser size than largest PD in V SCGCQ00698671 - (Port_Complete) - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties SCGCQ00652168 - (Port_Complete) - In HII ,Full initialization is not grayed out for R6 DIF arrays. SCGCQ00603251 - (Port_Complete) - Creation+ FW updation+ Scan foreign Configuration is disabled/grayed out in HII page SCGCQ00652424 - (Port_Complete) - change the numeric primitive's maximum from MAX_PHYSICAL_DRIVES to 0xff SCGCQ00698309 - (Port_Complete) - In HII ,Full initialization is not grayed out for R6 DIF arrays. SCGCQ00644788 - (Port_Complete) - Enhance help message for PD/VD Operation field SCGCQ00679036 - (Port_Complete) - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties SCGCQ00698543 - (Port_Complete) - HII is gave a option to start reconstruction from any degraded RAID level to RAID 0. SCGCQ00698650 - (Port_Complete) - HII does not display power state of a PD SCGCQ00698667 - (Port_Complete) - In HII Create VD option is enabled when resconstruction is in progress (on partial VD) SCGCQ00634684 - (Port_Complete) - RSOD during POST after enabling SecureBoot with OEM controller installed SCGCQ00644575 - (Port_Complete) - Consistency Check Start - remove mm/dd/yyyy from the string as the format is out of control of LSI SCGCQ00652169 - (Port_Complete) - HII reports wrong data under 'Eligible JBOD Drives for conversion' while converting JBOD to UG SCGCQ00693695 - (Port_Complete) - When Controller is in Safe Mode don't remove UCM formset SCGCQ00698429 - (Port_Complete) - change the numeric primitive's maximum from MAX_PHYSICAL_DRIVES to 0xff SCGCQ00698644 - (Port_Complete) - Minor Typos and consistency issues in HEFU HII help text SCGCQ00652170 - (Port_Complete) - HII is showing RAID levels, irrespective of drives to configure a new RAID level. SCGCQ00679049 - (Port_Complete) - "Make Unconfigured good" option missing in HII even if JBOD's are present in the config SCGCQ00682962 - (Port_Complete) - creation in HII is showing GB SCGCQ00698320 - (Port_Complete) - HII is showing RAID6 and RAID5 levels while creating VD when we have 2 512n drives and 1 4k Drives SCGCQ00698322 - (Port_Complete) - "Make Unconfigured good" option missing in HII even if JBOD's are present in the config SCGCQ00698447 - (Port_Complete) - Not able to create VD with 4k drives on intel wildcat server. SCGCQ00698627 - (Port_Complete) - HII is not displaying the cachecade 512GB warning message SCGCQ00644786 - (Port_Complete) - Enhance help message for PD/VD Operation field SCGCQ00682960 - (Port_Complete) - HII is not displaying the cachecade 512GB warning message SCGCQ00692302 - (Port_Complete) - TB creation in HII is showing GB SCGCQ00698547 - (Port_Complete) - HII is showing RAID levels, irrespective of drives to configure a new RAID level. SCGCQ00698661 - (Port_Complete) - Call UninstallStoreLib when we call StopControllerHiiImpl function WebBIOS 6.1-71-e_71-Rel ROMENV 1.08 PCLI 05.07.00 BootBlock 2.05.00.00-0010 NVDATA 2.1406.03-0135 Various changes for different OEMs. BootBlockCommon 07.26.26.219 FCODE 4.16.08.00 23.28.0-0015 (MR5.10 patch) Firmware 3.400.45-3507 SCGCQ00698155 - Machine Check exception occurs during cache offload SCGCQ00680070 - Preventing controller reset after running several hours with ASPM(Active State Power Management) enabled SCGCQ00618569 - HDD resume failed during dimmer switch test method. SCGCQ00646311 - Consistency Check media error handling is incorrect and can cause data integrity issue SCGCQ00670882 - Patrol read is in progress even after issuing stop patrol read command through App SCGCQ00664995 - At boot up, if a learn is required or a learn is in progress, do not wait for the SuperCap to charge. SCGCQ00643769 - Mechanism to override NVDATA Drive Activity LED setting SCGCQ00646299 - Cannot recover data from a recoverable media error after Patrol Read encounters recovery failure for RAID-1 SCGCQ00652191 - CacheCade data loss after reboot SCGCQ00598400 - For a particular OEM, size of some 4TB drives is reported as zero SCGCQ00692239 - Improve the benchmark test performance. SCGCQ00664994 - Increase the SuperCap learn time out value for 2GB TMM-B solution. SCGCQ00675291 - Battery/ Memory Problems are detected and cache offload does not happen with a 2GB Memory module/ SuperCap design. BIOS 5.46.02.1 SCGCQ00697504 - setting deviceExposure greater than or eaual to 128 will show wrong VD handled by bios SCGCQ00690943 - OEM wants the battery status text in BIOS to change from "missing" to "N/A" for iMR solutions. UEFI_Driver 0x06060A03 SCGCQ00688791 - Remove default value from numeric primitive that is present SCGCQ00698249 - Don't let user boot to OS until user discards dirty cache SCGCQ00698254 - Hii Image buffer clean-up SCGCQ00696371 - For OEM, change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00696543 - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00698238 - Do not go to WebBIOS due to a bad health status when WebBIOS is disabled in NVDATA. SCGCQ00644509 - CPU EXCEPTION ERROR During CSIOR Stage- After Updating idrac X38 to X39 (Dont double free the memory) SCGCQ00644856 - Install FMP on Controller Handle at Start() and the exception SCGCQ00661595 - Timeout is not passed correctly to FW SCGCQ00644859 - FMP GetImageInfo could result in stack corruption SCGCQ00698248 - Initilize the buffer that we allocate to load HII and return EFI_OUT_OF_RESOURCES if allocation fails SCGCQ00698250 - Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status SCGCQ00699147 - For OEM, don't free the host memory during disconnect/unload process Hii 03.07.12.02 SCGCQ00642232 - Ability to enable/disable JBOD mode in HII SCGCQ00644857 - Remove FMP installed on the controller handle in HII SCGCQ00644858 - RSOD during POST after enabling SecureBoot SCGCQ00661685 - HII reports wrong data under 'Eligible JBOD Drives for conversion' while converting JBOD to UG SCGCQ00698646 - Unable to set spinup drive count in HII SCGCQ00698664 - Not showing PD to assign as DHS to R50/ R60 VD if PD is of lesser size than largest PD SCGCQ00698671 - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties SCGCQ00698309 - In HII ,Full initialization is not grayed out for R6 DIF arrays. SCGCQ00698543 - HII is gave a option to start reconstruction from any degraded RAID level to RAID 0. SCGCQ00698650 - HII does not display power state of a PD SCGCQ00698667 - In HII Create VD option is enabled when resconstruction is in progress (on partial VD) SCGCQ00644575 - Consistency Check Start - remove mm/dd/yyyy from the string as the format is out of control of LSI SCGCQ00693695 - When Controller is in Safe Mode don't remove UCM formset SCGCQ00698429 - change the numeric primitive's maximum from MAX_PHYSICAL_DRIVES to 0xff SCGCQ00698644 - Minor Typos and consistency issues in HEFU HII help text SCGCQ00698322 - "Make Unconfigured good" option missing in HII even if JBOD's are present in the config SCGCQ00698320 - HII is showing RAID6 and RAID5 levels while creating VD when we have 2 512n drives and 1 4k Drives SCGCQ00698447 - Not able to create VD with 4k drives SCGCQ00698627 - not displaying the cachecade 512GB warning message SCGCQ00644786 - Enhance help message for PD/VD Operation field SCGCQ00692302 - creation in HII is showing GB SCGCQ00698547 - HII is showing RAID levels, irrespective of drives to configure a new RAID level. SCGCQ00698661 - Call UninstallStoreLib when we call StopControllerHiiImpl function WebBIOS 6.1-72-e_72-01-Rel SCGCQ00666796 - 9270 is not able to create RAID10 after CacheCade SSD VD created ROMENV 1.08 PCLI 05.07.00 BootBlock 2.05.00.00-0010 NVDATA 2.1403.03-0133 Various changes for different OEMs. BootBlockCommon 07.26.26.219 FCODE 4.16.08.00 23.28.0-0010 (MR5.10) Firmware - 3.400.05-3175 SCGCQ00482123 - External Key management security for iMR SCGCQ00499663 - Not seeing the correct Boot Message when the connection to the External Key Management server is down SCGCQ00518723 - Re-keying a controller with External Key Management(EKM) security enabled, results in a corrupted key ID. SCGCQ00523211 - Performing an online firmware update or Online Controller Reset(OCR) on a controller with External Key Management(EKM) enabled, results in all secured drives marked as foreign. SCGCQ00552222 - Raid configuration loss after reboot - PDs in POWERSAVE SCGCQ00557797 - Re-keying in External Key Management mode followed by disabling security and enabling LKM results in a bail out while creating a Virtual Drive SCGCQ00563760 - FW debugger scrolls continuous message and eventually resets after deleting Source VD during a Cachecade disassocation SCGCQ00569173 - Switching to Local Key Management Mode(LKM) after a rekey in External Key Management(EKM) rekey without rebooting results in HII saying key incorrect but Firmware says key was created. SCGCQ00570040 - On a controller with Local Key Management(LKM) enabled, user is asked to enter the security key to unlock and import a foreign, locked and External Key Management(EKM) enabled drive. SCGCQ00571671 - After starting Patrol Read in the HII application, booting to OS and checking the status in MSM shows Patrol Read as suspended. SCGCQ00574396 - Getting Question Value mismatch when entering Controller management screen SCGCQ00602011 - MR to iMR downgrade error SCGCQ00605773 - Pinned cache gets flushed to incorrect VD for mirrored RAID levels SCGCQ00619188 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap. SCGCQ00630411 - Cannot create pinned cache during an Online Controller Reset (OCR) SCGCQ00556744 - Switching the security mode from External Key Management(EKM) to Local Key Management(LKM) on iMR controller will result in a corrupted controller key. SCGCQ00571420 - Getting a non informative message when trying to import a Virtual Drive after a re-key without reboot SCGCQ00626852 - Internal Development team defect to check-in gemini image to resolve SSD drives missing issue. SCGCQ00530838 - Unable to suspend the Patrol Read operation in iMR mode from the HII application SCGCQ00530857 - Bad battery warning message that comes up during POST isn't aligned properly. SCGCQ00553023 - HDD status LED will be lit red after creating and deleting LD but the status is normal via MSM SCGCQ00579157 - Firmware break into montask, when there is a pinned cache( During bootup and OCR ) SCGCQ00601452 - Controller breaks into montask if you have 10 enclosures connected to the controller. SCGCQ00600478 - VD erase does not resume and complete after reboot. SCGCQ00556740 - A data TLB error occurs when the External Key Management Server(EKMS) is down and drive security is changed from External Key Management(EKM) mode to Local Key Management(LKM) mode. SCGCQ00579672 - Remove redundant code within a particular function SCGCQ00604555 - Storecli reporting incorrect values for tfm and supercap date of manufacture SCGCQ00575142 - Static analysis tool defects SCGCQ00596556 - Unable to discard pinned cache in Headless Safe Mode. SCGCQ00496086 - Enhance code to catch Stack Overflow problem as soon as it occurs. SCGCQ00554056 - Write buffer flash programming support SCGCQ00552197 - Implement I2C Slave Address for Sideband Management SCGCQ00604565 - Add Fastpath Support by Default for a particular OEM. SCGCQ00496648 - When pinned cache present VD property not changing from WB to WT. SCGCQ00496649 - PDs go online without VD created & App doesn't allow any VD creation on passing a wrong parameter in Spanned VD. SCGCQ00504674 - Booting a 12G server into a degraded Raid 5 array will result in limited functionality SCGCQ00504683 - Improve Boot time that was lengthened due to previous change. SCGCQ00556161 - (DDR3) CKE and Reset clamping circuit can cause DDR errors at initialization time SCGCQ00557763 - Incorrect variable type in MR Read/Modify/Write path SCGCQ00570105 - Gemini image updated SCGCQ00580318 - Raid configuration loss after reboot - PDs in POWERSAVE SCGCQ00603255 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset SCGCQ00603258 - OEM MR TB controller reports foreign configuration on adapter during a 100 AC power cycles SCGCQ00626839 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap. SCGCQ00477016 - FW sending wrong configuration data during boot msg pending state SCGCQ00498129 - I/O's fail and VD becomes failed during planned failover of owner node w/ SMB I/O SCGCQ00501146 - Configuration import of GHS (Global Host spare) fails. SCGCQ00502949 - Firmware hits Montask when drive is pulled after changing the volume property from read ahead to no read ahead. SCGCQ00522634 - VPD output of lspci vvxxx showing [RV] Reserved: checksum bad, 86 byte(s) reserved SCGCQ00555284 - Gemini image updated SCGCQ00556756 - disableBatteryWarning should not be reset if changed by user SCGCQ00600687 - An invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive SCGCQ00601379 - Fix for Infinite retries of command for sense code 0B/47/03 SCGCQ00613782 - Liberator Card loses its boot VD after many reboots SCGCQ00479699 - Upgrading from Software RAID to 9260-8i causes Alarm to sound SCGCQ00552759 - Incorrect variable type in MR Read/Modify/Write path SCGCQ00557614 - Bad or Missing TMM boot message is changed to Critical error SCGCQ00571404 - In case of a certain OEM iMR shows R5 enabled. SCGCQ00575043 - Running out of free entries in task list due to recursive addition of tasks SCGCQ00601892 - Fix for Infinite retries of command for sense code 0B/47/03 SCGCQ00606336 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset SCGCQ00609531 - Kill adapter is seen while performing CME recovery during Write operation. SCGCQ00609535 - CME logic using overlaid fields in c->rec SCGCQ00573950 - system black screen during S1 Sleep test SCGCQ00574335 - Operating System event log reports a controller error during stress testing SCGCQ00579738 - With Headless Continue On Error Mode(HCOE) enabled and the SafeStore BIOS password enabled, if the wrong password is entered you are stuck at the same screen . SCGCQ00600686 - An invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive SCGCQ00613783 - Liberator Card loses its boot VD after many reboots SCGCQ00502952 - Code Review: Call DDF_discardInvalidPds only if DS3 is enabled SCGCQ00504687 - FW take a long time to boot to OS SCGCQ00546684 - Cluster validation failed in disk arbitration SCGCQ00558263 - HDD status LED will be lit red after creating and deleting LD but the status is normal via MSM SCGCQ00570170 - Deep learn will not start immediately when Relative State of Charge (RSOC) of battery is equal to 95%. SCGCQ00570251 - Patrolread will not start on any VD after a PR is started, suspended and VD is deleted SCGCQ00575155 - VD goes offline when we start reconstruction on 32 Drive R0 VD SCGCQ00579225 - Clear up stale cache lines. SCGCQ00603257 - OEM MR TB controller reports foreign configuration on adapter during a 100 AC power cycles SCGCQ00609530 - MR 6.3: md5sum mismatch seen on a copied file from R5 VD with CME SCGCQ00570171 - Deep learn will not start immediately when Relative State of Charge (RSOC) of battery is equal to 95%. SCGCQ00556757 - search for one wire devices prints are masked after the boot BIOS - 5.46.02.0 SCGCQ00579962 - Initialize deviceExposure with MAX_INT13DISKS instead of 0xFF SCGCQ00572939 - Make sure all the make file adheres to the latest binary names. SCGCQ00559095 - Provide an option to limit the max number of INT 13h devices presented to system BIOS Hii - 03.07.11.00 SCGCQ00579816 - HII\EKM-LKM without reboot should show proper message SCGCQ00594011 - With out selecting any drives I am seeing the previous config VD size. SCGCQ00609737 - Confiuration Restore is not working SCGCQ00618674 - StartHiiImpl() WriteToLogger uses %g and EFIHiiDriverEntryPoint() Print statement uses %g for displaying EFI status SCGCQ00521488 - Getting error message when we suspend Patrol read operation through HII browser SCGCQ00565876 - Remove duplicated strings from the UNI FIle SCGCQ00571353 - Allow user to select RAID level when controller has other VD + error handling SCGCQ00573871 - fixing code review defects (AIM version + UCM GUID + deallocation) SCGCQ00614027 - Firmware updation fails SCGCQ00615221 - Form UF003 prints error messages (use WriteToLogger to log these debug messages) SCGCQ00617617 - FWMgmt Prtocol: has no "versionid" info. SCGCQ00565088 - Help content for Firmware Update in Controller Management is inappropriate SCGCQ00569098 - Enter security key for locked drives screen, press down to get to OK, OK will show up again on right SCGCQ00598822 - VD details display is improper in Expand Virtual Drive SCGCQ00613822 - Advanced Controller Properties- Power Saving Settings has broken form SCGCQ00556839 - Able to select EKM even when the EKM FOD key is removed from the system. SCGCQ00589301 - System/HII hang when clicks on Hardware Components menu option in HII. SCGCQ00595864 - On Success of creating Drive Security Form loads into Advanced controller properties SCGCQ00598431 - Drop Down option in VD properties for Cached is present SCGCQ00610889 - Customize help string for Select Interface Type SCGCQ00615190 - ill Controller Index in RouteConfig + for UF003 calculate checksume only for the actual config size SCGCQ00593558 - Auto Learn Mode is showing wrong data SCGCQ00612574 - Addressed review comments SCGCQ00613820 - Typo in HII form Controller Status SCGCQ00622464 - Toggling bewtween Legacy to Uefi mode vice versa junk values seen . SCGCQ00524969 - HII PKG 0006/Going from LKM to EKM asks for a Current Security key Identifier and Security key. SCGCQ00590465 - n selecting a wrong parameter for size while creating VDs, Options greyed, Create VD page exits to parent page. SCGCQ00595463 - Security feature is enabled but HII sees "Drive Security" as disabled SCGCQ00571359 - Typo "Clear Configuaration" -> "Clear Configuration" SCGCQ00573222 - Handling Code Collaborator Review Defects for SCGCQ00568814 and SCGCQ00569197 SCGCQ00575062 - added a while loop and take care of the multiple PD Groups scenario. SCGCQ00578190 - HII should calculate checksum before setting bios data SCGCQ00597641 - MR6.3 HII aesthetic change SCGCQ00503036 - Changing Percentage of Space to Expand Does not Update Final VD Size SCGCQ00574041 - AIM (Agentless Inventory Manager) Issues SCGCQ00574989 - Creation+ FW updation+ Scan foreign Configuration is disabled/grayed out in HII page SCGCQ00614466 - Under advanced controller properties and selecting Cache and Memory, it says's "scontroller cache" SCGCQ00614675 - To address FW Update help Strings SCGCQ00619028 - Not able to schedule CC in concurrent mode from HII(03.07.09.00). SCGCQ00526978 - HII. Provide controller FW update function SCGCQ00568814 - HEFU. Simplify controller propety page SCGCQ00568706 - Remove limitation for creating R6 in HII SCGCQ00612466 - Provide pop-up to display current version and update fw version as part of HEFU HII Firmware Update functionality SCGCQ00571579 - Create a formset with classGUID that customer has provided. SCGCQ00569197 - Move Disable Protection option from Controller Management to VD management SCGCQ00601110 - Able to select EKM even when the EKM FOD key is removed from the system. SCGCQ00557522 - System hang observed when the "PdInfo.userDataBlockSize" is set to 0 SCGCQ00601119 - HII help for Boot error handling does not display "Stop On Error" option SCGCQ00601107 - HII PKG 0006/Going from LKM to EKM asks for a Current Security key Identifier and Security key. SCGCQ00601103 - Enter security key for locked drives screen, press down to get to OK, OK will show up again on right SCGCQ00601113 - HII\EKM-LKM without reboot should show proper message SCGCQ00601117 - UCM Phase 1: Allow user to select RAID level when controller has other VD + error handling SCGCQ00572986 - System hang observed when the "PdInfo.userDataBlockSize" is set to 0 SCGCQ00603235 - HII help window shows unsupported stripe sizes SCGCQ00596920 - Missing BBU caused disappearance of Enclosure Mgmt opt in BIOS setup SCGCQ00601120 - In HII on a ready drive we are able to see Used space as 40Gb. SCGCQ00601118 - Typo "Clear Configuaration" -> "Clear Configuration" SCGCQ00601116 - added a while loop and take care of the multiple PD Groups scenario. FCODE - 4.16.08.00 UEFI_Driver - 0x06060900 SCGCQ00618669 - UEFI Driver: StartHiiBackEnd() has Print statement with %g SCGCQ00578194 - UEFI Driver should calculate checksum before setting bios data SCGCQ00601851 - System hang when we press F1 on second time when we are in HII form SCGCQ00628627 - UEFI Driver- has debug print statements during POST SCGCQ00589148 - Diskpart EFI utility can't create partition on a JBOD SCGCQ00526851 - Support EFI_FIRMWARE_MANAGEMENT_PROTOCOL for controller firmware SCGCQ00579837 - UEFI Driver should calculate checksum before setting bios data SCGCQ00606367 - UEFI Driver returns EFI_NOT_FOUND when platform passes valid SCGCQ00580313 - User can't access RAID HII in UEFI mode after removing a HDD WebBIOS - 6.1-71-e_71-Rel NVDATA - 2.1403.03-0128 SCGCQ00563766 - Added support for subOEM 8 version of Alcor-S 9271 Controller PCLI - 05.07.00 BootBlock - 2.05.00.00-0010 BootBlockCommon - 07.26.26.219 ROMENV - 1.08 23.22.0-0020 (MR5.9 patch3) Firmware - 3.340.55-3173 SCGCQ00619188 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap. BIOS - 5.45.07.0 Hii - 03.05.11.03 FCODE - 4.16.08.00 UEFI_Driver - 0x06030501 WebBIOS - 6.1-71-e_71-Rel NVDATA - 2.1312.03-0124 PCLI - 05.07.00 BootBlock - 2.05.00.00-0010 BootBlockCommon - 07.26.26.219 ROMENV - 1.08 23.22.0-0017 (MR5.9 patch2) Firmware - 3.340.35-3075 SCGCQ00552222 - Raid configuration loss after reboot - PDs in POWERSAVE SCGCQ00531244 - Display the NCQ enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI SCGCQ00557763 - Incorrect variable type in MR Read/Modify/Write path SCGCQ00570105 - Gemini image updated - SCGCQ00603258 - OEM MR TB controller reports foreign configuration on adapter during a 100 AC power cycles SCGCQ00600686 - An invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive SCGCQ00601379 - Fix for Infinite retries of command for sense code 0B/47/03 SCGCQ00570170 - Deep learn will not start immediately when Relative State of Charge (RSOC) of battery is equal to 95% BIOS - 5.45.07.0 Hii - 03.05.11.03 FCODE - 4.16.08.00 SCGCQ00553069 - PCLI(1.07.05) Sparc: Command "cli set securitykey=xxxxxxx" fails with errcd "1001" and errmsg "invalid key". UEFI_Driver - 0x06030501 WebBIOS - 6.1-71-e_71-Rel NVDATA - 2.1312.03-0124 PCLI - 05.07.00 BootBlock - 2.05.00.00-0010 BootBlockCommon - 07.26.26.219 ROMENV - 1.08 23.22.0-0012 (MR 5.9) **NOTE: Full native 4K sector Firmware support is provided in firmware since MR 5.8 release Firmware 3.340.05-2939 SCGCQ00358434 - StorCLI: Showing success for assigning a secured VD to cachepool whereas the operation is failure. SCGCQ00441316 - Supercap is not detected but cache offload and restore happens SCGCQ00476320 - Faulty protocol used for changing the Disk Write Cache Policy SCGCQ00504475 - Unable to create another Virtual Drive when pulling first drive (degrading) in partial Virtual Drive where all drives are configured SCGCQ00518693 - Active/suspended patrol reads not terminated during VD deletion SCGCQ00522321 - Error message displayed after suspending a Patrol Read Operation using the HII application SCGCQ00522381 - Incorrect information is returned for SATA drive when the drive is connected behind the interposer. SCGCQ00473201 - Firmware montask when solaris is installed on 4 drive Raid6 with 2 drive failure SCGCQ00552847 - Data Integrity issue found with CacheCade when CacheCade disassociation is initiated after running IO SCGCQ00487288 - The Firmware does not change the Virtual Drives's from Write Through to Write Back after a battery manual learn cycle is complete SCGCQ00501286 - Baseboard Management Controller (BMC): STP passthru command failure SCGCQ00500984 - HII - Last physical drive in 84 physical drive enclosure is displayed 4 times SCGCQ00501630 - Drive security mode switching in MSM SCGCQ00476528 - When I/Os are running on SATA Physical Drives with interposers, a drive removal and reinsertion within drive-removal-delay comes back as failed. SCGCQ00484803 - The Firmware does not change the Virtual Drives's from Write Through to Write Back after a battery manual learn cycle is complete SCGCQ00552110 - Gemini image updated SCGCQ00333207 - Request to support 128 drives within single enclosure SCGCQ00466994 - Added support in FW to import CC1.x VDs. SCGCQ00467207 - Support Revision 17 and Revision 18 Supercaps SCGCQ00501863 - Clustered Media Error handling does not work for read operations during RAID-5 writes SCGCQ00479734 - When Cachecade LD is deletec invalid LD details is shown in the Cachecade size changed event. SCGCQ00487279 - MR Controller does OCR due to Temp Buffer overflow SCGCQ00498098 - 9240-4i on BCM RX67Q-6S motherboard is not getting required memory resources on boot SCGCQ00479736 - D_SENSE bit in Mode Select Page=0a is set for < 2TB disk SCGCQ00479732 - T-bolt MR (PL) FW : Invalid "mode select(Page=0a)" issued during disk initialization phase. SCGCQ00479499 - iMR TB Data loss when reconstructing from 1 drive R0 to 2 drive R1 with reboot SCGCQ00480237 - For iMR, Firmware is faulting when trying to flash firmware after Online Control Reset. SCGCQ00501862 - Clustered Media Error handling does not work for read operations during RAID-5 writes SCGCQ00481029 - Storcli: wrong error code displayed and wrong error message for copyback command SCGCQ00557108 - Data Integrity issue found with CacheCade when CacheCade disassociation is initiated after running IO SCGCQ00470407 - Remove support of a certain TMM-B from currently released firmware SCGCQ00504011 - Cache offload is started when server's power down (DC Off) on WebBIOS or Post phase. SCGCQ00505203 - Validate the requested blocks for SCSI VERIFY commands on RAID volumes SCGCQ00484048 - Faulty protocol used for changing the Disk Write Cache Policy SCGCQ00471478 - Firmware crash seen while doing continuous sas cable pull SCGCQ00467493 - Foreign config import is getting failed when using multiple enclosures SCGCQ00505732 - Firmware montask when solaris is installed on 4 drive Raid6 with 2 drive failure SCGCQ00490891 - Firmware Crash during Controller StartUp when large number of drives are connected SCGCQ00480242 - For iMR, Firmware is faulting when trying to flash firmware after Online Control Reset. SCGCQ00493102 - Can't import foreign configuration on degraded arrays after system reboot SCGCQ00480234 - A single supercap pack should not be supported on a 2GB memory module SCGCQ00501103 - Validate the requested blocks for SCSI VERIFY commands on RAID volumes SCGCQ00485583 - For a particular OEM fault LED does not come on when a bad HDD is inserted SCGCQ00479709 - Firmware returns asc value as 0 when failing IOs with medium errors SCGCQ00471470 - Firmware crash seen while doing continuous sas cable pull SCGCQ00493101 - Can't import foreign configuration on degraded arrays after system reboot SCGCQ00479731 - Foreign config import is getting failed when using multiple enclosures SCGCQ00472867 - Defect Fix for Excessive unexpected sense events reported on PI enabled R5 VDs SCGCQ00479737 - Installing and uninstalling iMR FOD key overwrites MR controller features SCGCQ00472864 - Defect Fix for Excessive unexpected sense events reported on PI enabled R5 VDs SCGCQ00479502 - iMR TB Data loss when reconstructing from 1 drive R0 to 2 drive R1 with reboot SCGCQ00479721 - Intermittent SEP errors on iMR and MR controllers SCGCQ00487278 - MR Controller does OCR due to Temp Buffer overflow WebBIOS 6.1-71-e_71-Rel SCGCQ00333215 - Request to support 128 drives wihin single enclosure SCGCQ00488500 - Added support for OEM controller whose PCI subsystem Id is 2208 SCGCQ00488501 - Added support for OEM controller whose PCI subsystem Id is 2240 SCGCQ00488502 - Added support for OEM controller whose PCI subsystem Id is 0001 NVDATA 2.1312.03-0124 SCGCQ00493673 - StorCli does not list all the available BBU modes. BIOS 5.45.07.0 SCGCQ00479507 - FW 3.340.05-2739/Getting memory conflict during boot SCGCQ00495471 - OOB function corrupts EBDA area used by other server function SCGCQ00493680 - Optimize reading IO port in INT15h path SCGCQ00552308 - OEM system is not allocating memory correctly when MR and iMR are in the same system SCGCQ00482283 - iMR: System reboots during IO because FW didnt receive permanent host memory from OpROM SCGCQ00503046 - OpROM is displaying incorrect value for the number of INT13h device it supports SCGCQ00466276 - Check the controller status bit in the function which hooks INT15 SCGCQ00454086 - Add boundary checking when allocating EBDA and PMM memory for BIOS post. SCGCQ00460724 - Memory access issue when loading Ctrl R SCGCQ00460725 - Memory allocation: Allocate only two 64k PCLI 05.07.00 SCGCQ00472311 - (CBB) Provide mechanism to disable PCIe backchannel training via SBR UEFI_Driver 0x06030500 SCGCQ00479003 - Disable Debug print in UEFI Driver SCGCQ00435384 - UEFI System hang if controller FW is in fault state SCGCQ00498925 - Not able to boot into BIOS boot menu SCGCQ00493654 - Memory Leak issue in UEFI driver when reconnect happens SCGCQ00518791 - DriverDiagnostics2.c: In IsValidHandle() - Free the buffer if status is not EFI success for LocateHandle SCGCQ00483847 - EKMS: Remove private GUID and use EFI_KMS_PROTOCOL_GUID defined in UEFI 2.3.1 spec SCGCQ00484086 - hang when SATA is connected SCGCQ00468948 - Uninstall HII CAP and Driver Health formset if platform calls Start again without calling GetHealthStatus SCGCQ00477828 - 9240/9260/9270 UEFI driver issue when user having 2TB or 4TB VD SCGCQ00478692 - Block IO tests from SCT IHV test suite failed SCGCQ00484114 - Follow UEFI Spec on interpreting In and Out Transfer Length that upper layer sends Hii 03.05.11.00 SCGCQ00470101 - Allow user to edit VD size (that is free form input) as it is cumbersome to modify the size using +/- SCGCQ00471830 - Save and Restore Configuration SCGCQ00556209 - Transition a MR controller to run in iMR mode = Controller fail in HII After Memory removed SCGCQ00556811 - HII - When controller is in safe mode the PD menu displays inaccurate text and hangs when clicking a PD SCGCQ00529287 - Profile Based Raid1 Creation fails as invalid arguments SCGCQ00502940 - Naming inconsistency in option present in Create VD and Create VD - Advanced SCGCQ00482092 - HEFU_HII: condition checking is not right SCGCQ00474402 - HII: Allows user to select EKM mode when supportEKM is set to 0 SCGCQ00485401 - 5.9 PKG 0002 HII/Using 84 PD encl when clicking on HW, Advanced then Enclosure Management, it completly freezes the system SCGCQ00473204 - MR UCM 2.0: unable to show UF003 as well the first two forms + XML special character handling SCGCQ00486457 - HEFU_HII_MR6.2: fixing memory leak of 128 drive enclosure implementation SCGCQ00505566 - MR 6.2-HII: Drop down option to set phy linkspeed tp 12 Gbps in HII browser is not available. SCGCQ00473186 - Save and Restore Configuration - MR w/ Premium Features (SED and Cachecade) SCGCQ00501111 - HII 3.05.07.00/Issues when trying to change EKM security key from change security key option. SCGCQ00523869 - EKMS\HII PKG 0006\EKMS is down but it is still possible to select drive security in MSM and HII during creation. SCGCQ00527700 - Update the latest API change in HEFU SCGCQ00500945 - MR: EXPAND operation fails in HII for prl11 SCGCQ00494431 - Streamline the usage of max PD in limited configuration path (alias UCM) SCGCQ00494214 - Help content for Free space in Select Drive group is inappropriate SCGCQ00485932 - UCM Simple Configuration: Allow Clear Config always + Suppress Checkbox (Uf002.PDs) when VD count is >0 SCGCQ00472196 - Profile based VD creation path incorrectly showing protect VD/secure VD checkbox when user clicks on drive selection criteria SCGCQ00481284 - Typos in help content for profile VD for Write Policy SCGCQ00471209 - UCM Phase2: config using 8PDs/16 partial VDs and all stripe sizes and HSPs does not restore SCGCQ00487936 - UCM-After creating a VD with UCM tool the manual configuration PD section still shows configured PDs as UG, and duplicates SCGCQ00495236 - Controller not seen in HII Browsercan after switiching from EFI WebBIOS SCGCQ00505591 - Checking the Enclosure Management settings in HII causes the system to reboot. SCGCQ00475217 - Request to support 128 drives wihin single enclosure SCGCQ00468930 - UCM Phase 2 support SCGCQ00481277 - Request to change the help content for write policy in create VD form SCGCQ00415456 - Obtain the Physical Slot number from the PCI Bridge to which the Controller is connected. SCGCQ00476607 - HII cannot assign partial space less than 1 GB SCGCQ00498521 - MR 6.01 : HII cannot create a VD using unconfigured good drives as long as PD locate is set on the drives FCODE 4.16.07.00 SCGCQ00471703 - Fcode CLI support for Invader (MR only) SCGCQ00486355 - Define and use capability bit to identify the StorCLI BootBlock 2.05.00.00-0010 BootBlockCommon 07.26.26.219 ROMENV 1.08 23.18.0-0014 (MR5.8 patch1) MR Firmware - 3.290.15-2935 SCGCQ00552847 - Data Integrity issue found with CacheCade when CacheCade disassociation is initiated after running IO SCGCQ00484803 - The Firmware does not change the Virtual Drives's from Write Through to Write Back after a battery manual learn cycle is complete SCGCQ00449662 - Foreign config import is getting failed when using multiple enclosures SCGCQ00457913 - Defect Fix for Excessive unexpected sense events reported on PI enabled R5 VDs SCGCQ00459680 - iMR TB Data loss when reconstructing from 1 drive R0 to 2 drive R1 with reboot SCGCQ00470499 - For iMR, Firmware is faulting when trying to flash firmware after Online Control Reset.] SCGCQ00477801 - MR Controller does OCR due to Temp Buffer overflow SCGCQ00481595 - Can't import foreign configuration on degraded arrays after system reboot SCGCQ00449115 - Clustered Media Error handling does not work for read operations during RAID-5 writes SCGCQ00473201 - Firmware montask when solaris is installed on 4 drive Raid6 with 2 drive failure SCGCQ00552110 - Gemini image updated SCGCQ00467625 - Validate the requested blocks for SCSI VERIFY commands on RAID volumes BIOS - 5.42.00 Hii - 03.03.07.00 UEFI_Driver - 0x06010300 FCODE - 4.14.05.00 WebBIOS - 6.1-68-e_68-Rel NVDATA - MR2.1310.03-0122 PCLI - 05.07.00 Ctrl-R - 4.02-0001 BootBlock - 2.05.00.00-0010 BootBlockCommon - 07.26.13.219 ROMENV - 1.08 23.18.0-0013 (MR5.8) MR Firmware - 3.290.05-2720 **NOTE: Full native 4K sector Firmware support is provided in this release SCGCQ00462339 - Virtual Drive creation failure in iMR during pre-boot SCGCQ00454816 - Recon VD made "degraded" when the recon pd is pulled out allowing for rebuild once the drive is plugged back in. SCGCQ00448786 - static variable used in PD Progress and LD Progress function which may affect multiple progresses running at the same time. SCGCQ00437008 - MegaRAID controller does not display a boot message when it has entered safe mode. SCGCQ00435944 - Allow adding a lba when table entries are exhausted, but addition is possible if consecutive to existing entry SCGCQ00434388 - When pulling and pushing SSD SATA PDs under 5 seconds, the SSDs come back as failed after a minute or so. SCGCQ00420777 - Fw defect in PdStateSet() SCGCQ00419399 - Hard coded values should be removed in TFM module SCGCQ00414056 - Potential IO integrity with R0/R1 CIO WT when overlapping R/W issued to LD. SCGCQ00413472 - Unable to perform Consistency Check and other background operations in a legacy WebBIOS SCGCQ00413254 - Multiple VDs undergoing full init show a calculated estimated time remaining even though they sit at 0% SCGCQ00406688 - Static Code Analysis Tool warnings: IDs - 10007 , 10338 , 10340, 10356, 10364 , 10371, 10389, 10390, 10847, 10848 SCGCQ00406301 - Static Code Analysis Tool warnings 10071, 10100, 10162, 10174, 10288, 10332, 10361, 10363, 10503 SCGCQ00406219 - FW reports "Progress init not proper" during 16 VD Rebuild SCGCQ00400809 - Data miscompare seen when errors injected to a RAID6 virtual drive SCGCQ00400807 - Potential data integrity issue During Check Consistency On 4DG R6 arrays with 16 VDs per array SCGCQ00400564 - Delete VD while PR still in progress cause debugger to loop. Reboot the system, debugger still loops SCGCQ00393749 - MonTask: line 281 in file ../../raid/mem.c if running megacli AdpDiag SCGCQ00349837 - Sequential Read performance is less on CacheCade associated LD's. SCGCQ00451137 - If a BOOT Passphrase is enabled with SafeStor "MegaCli adpbios dsply a0" will display "BIOS will Stop on error" even if any other mode is set. SCGCQ00447927 - Message release issue in immediate IO path SCGCQ00446623 - Firmware crash during foreign config import SCGCQ00441299 - Updated line of code recommended in code review. SCGCQ00439477 - Verify drive reinsertion within/before drive-removal-delay setting -verify discovery (Without IO) SCGCQ00425796 - HII - Profile based VD creation - [Partial RAID options blocked until system reboot] SCGCQ00424928 - Application could not make a JBOD bootable without a VD present SCGCQ00423182 - bootMsgPending.needsEKM bit is not set when FW needs a key SCGCQ00422760 - Indifference between MR.H and FW implementation for lockKeyLength SCGCQ00420918 - Potential data integrity issue with a 4K RAID5 virtual drive SCGCQ00412766 - HII /When user has a critical message and the conrtoller is in Safe Mode, going into CTRL mang will result an error msg SCGCQ00404263 - Staggered CMEs across R10 array are causing a read error SCGCQ00475140 - Learn cycle will not start on supercap SCGCQ00451213 - Assertion failure in raid 1078main.c at line 993 during hibernation when IOs or background operations are running SCGCQ00448750 - UEFI-4K drives: Unable to create any virtual drives of strip size 256k-1MB with the 4K sector drives. SCGCQ00439050 - Static Code Analysis defects - 5.8 SCGCQ00436460 - Event is blocked during Full initialization SCGCQ00422757 - iMR firmware does not progress background operations with certain systems when using WebBIOS in legacy mode SCGCQ00420702 - Fw defects related to Disk Write Cache Policy settings SCGCQ00406148 - Grammatical spacing error in bios message at POST SCGCQ00400555 - The elapsed time shown in the FW debugger for a reconstruction not starting at 0 SCGCQ00399591 - 23.16.0.0005/Creating CacheCade with non supported OEM SSD using older FW and then flashing to 5.7 it's till available SCGCQ00398281 - "Question value mismatch with Option Value" message in HII's Controller Management when in Safe Mode with pin cache SCGCQ00393347 - Static Code Analysis Tool code changes SCGCQ00448628 - Rebuild failed event is not seen when rebuild fails due to LDBBM and SBBM tables getting full (puncturing disabled) SCGCQ00439947 - Static analysis tool defects SCGCQ00437731 - Remove memory module on MR controller to downgrade to iMR does not work SCGCQ00415473 - Fix code review defect D16582 in 5.8 stream for Review #17785: NCQ support is disabled in FW SCGCQ00400149 - Firmware failed to import drives to start rebuild after remove then reinsert SCGCQ00462008 - LDBBM_EXT table does not get read during init SCGCQ00443920 - Static analysis tool defects SCGCQ00440224 - Corrected defects found by static analysis tool. SCGCQ00439068 - Static analysis tool defect fixes SCGCQ00404301 - Significant drop in Sequenial read performance with Read Ahead policy SCGCQ00449597 - Multi-stripe size in each raid level of R1,r5,r6 with SAS, DIF, 4K pinned cache offline vd import cause Montask SCGCQ00446657 - Static Code Analysis Tool - Defect Code Changes SCGCQ00443455 - Static Analysis Defects SCGCQ00424293 - Setting the ASO key with storcli 1.02.08 (MegaCli 8.07.06) fails with an error code 3 on Windows or Linux if the MB BIOS PCI SCGCQ00406233 - Data Miscompare found while running I/O overnight with degraded virtual drives SCGCQ00443883 - Static code analysis tool fixes SCGCQ00436287 - HII critical message form/Extra character "r" with configuration not supported critical message. SCGCQ00399227 - Prevent overtemp warnings while battery is charging SCGCQ00411672 - CLI Reporting of TMM VPD SCGCQ00472756 - EKMS disabled in firmware by modifying support EKM property in a proper way. SCGCQ00399224 - Modify MR fw to eliminate four second window where drive swap is not recognized. SCGCQ00399233 - Rebuild automatically starts on drive with foreign configuration after reboot. SCGCQ00377263 - Modify sense data returned for an offline VD SCGCQ00399229 - Availability of information on PFK hardware keys presence/absence via termlog. SCGCQ00403115 - HA/Peer controller detection and handling logic SCGCQ00331562 - R5 rebuild fails source drive after LDBBM table is full SCGCQ00396289 - Defect fix for crash when fde disk connected SCGCQ00396296 - Ctrl+R BIOS hangs while hot plug of 2 enclosures with more than 32 drives on FURY controller SCGCQ00397338 - CC2.1_RA_Support : Data Integrity issue may happen upon creating WB CCVD during Cache Flush SCGCQ00397347 - Sequential Read performance is less on CacheCade associated LD's. SCGCQ00409501 - The reliability and error recovery of the SuperCap firmware was improved. SCGCQ00414020 - Adjusted the USB phy boost value for the OEM controllers SCGCQ00414463 - IO integrity error seen after Source VD associated with CacheCade VD is forcibly unblocked SCGCQ00414466 - During rebuild on PRL11 CacheCade VD and rebuild on RAID6 Source VD IO integrity error is seen. SCGCQ00417742 - BBU Charging gets disabled when Transparent Relearn fails to start due to low capacity SCGCQ00421945 - on iMR FW update caused card to FW fault state and card cannot boot to OS. SCGCQ00421967 - SEAGATE hotspare drives remain spun up on LSI FW 12.12.0-0079 SCGCQ00424028 - After COR (OCR) controller not longer available to HOST SCGCQ00426998 - Code Review defect to handle SA_INVALID_FIELD_IN_CDB SCGCQ00427028 - Change SES Green/Amber LED behavior for OEM JBOD enclosure. SCGCQ00427030 - Customer is hitting an ECC bug SCGCQ00427031 - Firmware returns invalid data in OOB packet SCGCQ00435303 - OEM facing with incorrect SAS HDD's indication, MSM shows 2X drives connected SCGCQ00435305 - Alarm continues to sound after copy-back is done, across reboot, from an unconfigured good drive that is used as an emergency spare. SCGCQ00436807 - Change RAID controller FW bad battery warning message that comes up during POST. SCGCQ00439490 - 9260 controller VD goes offline during Slow/Full/Foreground Initialize with 3TB Seagate SED SAS drives SCGCQ00442108 - 2208 ROMB see 0 Capacitance SCGCQ00462321 - Deep learn doesn't start when it is requested during relaxing. SCGCQ00340844 - Don't interpret the cachecade BVD flags if the volume is created with old FW which does not support cachecade. SCGCQ00357678 - immediate IO broken for R1 - (SCGCQ00357549) SCGCQ00384609 - Assertion failure in ../../raid/raidpci.c at line 10011 , while running IO with medium errors on arrays. SCGCQ00405889 - Auto Foreign import fails when controller is booted with pinned cache. SCGCQ00406635 - Power loop cycle test on a non DIF drive connected to LSI controller caused fatal firmware error SCGCQ00414469 - When a Cachecade PD marked as missing is reused to make Cachecade VD IO integrity error is observed. SCGCQ00418100 - If a correctable ECC error occurred during a cache offload, the CPU would crash, resulting in a data loss SCGCQ00418526 - montask hit at the line "Fatal firmware error: Line 1057 in ../../dm/src/dm.c while running copyback with 255 ME SCGCQ00424266 - Disable Band Gap feature for select customers SCGCQ00424272 - Disable Band Gap feature for select customers SCGCQ00426122 - Megamon issue when disabling the drive security on a MR controller with spun down FDE drives. SCGCQ00426172 - Copyback on a drive hits kill adapter SCGCQ00426433 - Setting the ASO key with storcli 1.02.08 (MegaCli 8.07.06) fails with an error code 3 on Windows or Linux if the MB BIOS PCI SCGCQ00426961 - immediate IO broken for R1 SCGCQ00427002 - disableHII: Needs to be updated from nvdata into MFCD SCGCQ00427591 - Infinite retry happens on Test Unit command when HDD didn't respond to TU command during the initialization. SCGCQ00432566 - Enable DS3 on TB code for OEM SCGCQ00450108 - TFM error handling : Cache policy change for WB to WT if supercap is faulty SCGCQ00455801 - OEM- StorCli should not allow turning on JBOD in MR mode SCGCQ00462305 - Deep Learn is not invoked in new battery, when the system is reboot before the first learn completes SCGCQ00462319 - Transparent Learn Cycle is rescheduled even though it is not completed SCGCQ00468434 - Write policy changed from WT to WB when the battery/Supercap is declared as bad SCGCQ00355900 - OCR observed after IO on reconstructed VD with ME's SCGCQ00381325 - Wrong event generated "Reminder: Potential non-optimal configuration due to drive PD xx(e0xfc/sx) commissioned.. SCGCQ00418110 - If the hotspare was spun down, the copyback after a drive failure wouldn't always start. SCGCQ00421950 - adapterOperations.alarmControl is being set to 1 even if controller doesnot have alarm on board SCGCQ00421964 - 9240-4i on one motherboard is not getting required memory resources on boot SCGCQ00421966 - Unable to open "Set Patrol Read Properties" in MSM with 2008-iMR SCGCQ00426092 - Megamon during Injecting errors to VD with 512e PDs on iMR controller SCGCQ00426194 - If VD is secured while reconstruction is going on does not stay secured once reconstruction is done. SCGCQ00427013 - Allocate BBLog for iMR Initally during boot up SCGCQ00427018 - When attempting to secure LD during RLM, receive option to secure LD, LD not secured (message incorrect/misleading.) SCGCQ00432842 - Saved Release Note DataSLIB returning bad data as good data after host reboots SCGCQ00436873 - Minimum Capacity needed for relearn is incorrect in 2208 MR FW SCGCQ00438483 - Improve foreign config import for iMR with mixed JBOD/RAID settings SCGCQ00446741 - Correct the error in copy back path smart errors path SCGCQ00456440 - Defect fix for VD rebuild doesnot kickin and goes to foreign state after reboot SCGCQ00464629 - Disconnect SCap during Shutdown/Hibernate only if pinned cache is not present SCGCQ00364724 - Assertion failure in ../../raid/raidpci.c at line 8323 while running IO with cable pull/push. SCGCQ00426204 - spare pointer is incorrectly used in MR_CONFIG_DATA SCGCQ00427032 - Fix For code analysis Defects Reported SCGCQ00432754 - Customer experiencing extremely long rebuild times under I/O with LSI 9288-8e Procyon-U) controller SCGCQ00436808 - Change RAID controller FW bad battery warning message that comes up during POST. SCGCQ00441823 - Patrol Read - no progress SCGCQ00450643 - 9260-8i(SAS2108) hitting OOB SRAT timeout for a long time causing OOB commands to fail SCGCQ00397250 - ECC/Medium/Unrecoverable read errors handling Enhancement SCGCQ00405886 - FW halts when you have pinned cahce and remove VD form the configuration. SCGCQ00418112 - If the hotspare was spun down, the copyback after a drive failure wouldn't always start. SCGCQ00421977 - Invalid target ID after new logical drive creation SCGCQ00427021 - sync error stat for MRS SCGCQ00427022 - megacli reports battery pack is missing on hot insertion SCGCQ00448174 - Card Running iMR Machine Checks when Requesting Host Memory SCGCQ00421953 - 9260-16i's drive locate/fault LED header doesn't work SCGCQ00427592 - Infinite retry happens on Test Unit command when HDD didn't respond to TU command during the initialization. SCGCQ00453504 - Defect Fix for Exception in Core 0 SCGCQ00456361 - Virtual drive configurations go missing during firmware upgrade from 5.3 to 5.7, while running Consistency Check (CC), after tworeboots SCGCQ00387315 - fix for the defect - 4k drives display wrong value of Coerced size. SCGCQ00454959 - Write policy changed from Write-through (WT) to Write-back (WB) when the battery/Supercap is declared as bad BIOS - 5.42.00 Hii - 03.03.07.00 SCGCQ00472196 - Profile based VD creation path incorrectly showing protect VD/secure VD checkbox when user clicks on drive selection criteria UEFI_Driver - 0x06010300 SCGCQ00435384 - UEFI System hang if controller FW is in fault state SCGCQ00392836 - Support Remote Key Management FCODE - 4.14.05.00 SCGCQ00418701 - Not possible to probe a volume > 2Tb on Niwot raid card WebBIOS - 6.1-68-e_68-Rel SCGCQ00414398 - In WebBIOS, if BGI is suspended the vd progress info page shows it as CC progress until it is resumed SCGCQ00471031 - Incompatible strip size convention in TB NVDATA - MR2.1310.03-0122 SCGCQ00419769 - Change in product name for OEM 2208 ROMB design SCGCQ00447780 - Added support for OEM controller SCGCQ00452126 - Updated OEM controller SCGCQ00459367 - Updated OEM controller PCLI - 05.07.00 Ctrl-R - 4.02-0001 BootBlock - 2.05.00.00-0010 BootBlockCommon - 07.26.13.219 ROMENV - 1.08 23.16.0-0018 (MR5.7p1) Firmware - 3.270.65-2578 - Virtual drive configurations go missing during firmware upgrade from 5.3 to 5.7, while running Consistency Check (CC), after two reboots - Card Running iMR Machine Checks when Requesting Host Memory Hii - 03.02.08.00 BIOS - 5.42.00 WebBIOS - 6.1-65-e_65-Rel PCLI - 05.07-00 NVDATA - 2.1304.03-0117 BootBlock - 2.05.00.00-0010 Common BootBlock - 07.26.13.219 23.16.0.0012 (MR 5.7) Firmware - 3.270.05-2430 Fixes **NOTE: Although several 4K sector changes are listed below, full native 4K sector support is defered to MR5.8 release. - Potential IO integrity with R0/R1 CIO WT when overlapping R/W issued to LD. - Unable to perform Consistency Check and other background operations in a legacy WebBIOS - Multiple VDs undergoing full init show a calculated estimated time remaining even though they sit at 0% - 'Static Code Analysis Tool' warnings: IDs - 10007 , 10338 , 10340, 10356, 10364 , 10371, 10389, 10390, 10847, 10848 - 'Static Code Analysis Tool' warnings 10071, 10100, 10162, 10174, 10288, 10332, 10361, 10363, 10503 - FW reports "Progress init not proper" during 16 VD Rebuild - Delete VD while PR still in progress cause debugger to loop. Reboot the system, debugger still loops - MonTask: line 281 in file ../../raid/mem.c if running megacli AdpDiag - Firmware crash during CME recovery - 5.7Static Code Analysis Tool changes - 'Static Code Analysis Tool' Defect OVERRUN STATIC: CIDs Out-of-bounds access - Code Analysis Tool fix - Sequential Read performance is less on CacheCade associated LD's. - Application could not make a JBOD bootable without a VD present - In HII, when user has a critical message and the conrtoller is in Safe Mode, going into CTRL Management will result an error msg - Significant drop in Sequenial read performance with Read Ahead policy - Staggered CMEs across R10 array are causing a read error - MR5.6 Beta Firmware BST: Code Analysis Tool Fix - Continues PR 2nd time on Raid 1 and then delete VD and reboot system cause debugger to continues loop and want to run PR - 5.7 FW PKG 23.11.0-0013/Using CLI, can change a cachecade PD to WB even though enableSSCWB=0 - Firmware does not progress background operations with certain systems when using WebBIOS in legacy mode - Grammatical spacing error in bios message at POST - The elapsed time shown in the FW debugger for a reconstruction not starting at 0 - "Question value mismatch with Option Value" message in HII's Controller Management when in Safe Mode with pin cache - Removed unwanted prints. For copyBack, total Blocks for copyback was not getting intitailized for right drive. Initialized for copyBack destination PD. Added necessary fix. - Code Analysis Tool Defect OVERRUN STATIC: CIDs Out-of-bounds access - Assertion failure fixed for issuing "adpdiag" from megacli-dos - Correct formatting and compilation issues - Firmware failed to import drives to start rebuild after remove then reinsert - Fixes for defects found by Static Code Analysis Tool - 'Static Code Analysis Tool' code changes - Firmware is sending totalElapsedSecs value as 0 for LD and PD progresses - MegaCli pdFwDownload fails on a SATA drive with an interposer (parent defect is SCGCQ00352210) - Timed critical boot message under UEFI mode not showing - Fix for Firmware asserted when VDs are offline - Code Analysis Tool Fix - Firmware blocked firmware download to interposer - NCQ support is disabled in FW - Double media error getting corrected during check consistency - Data Miscompare found while running I/O overnight with degraded virtual drives EnhancementRequests - 4K sector support - Cache Mgmt, Snapshot, LD config, RAID ** - CME handling improvements for handling multi-row I/Os - 4K sector support - Switch to enable/disable 4K feature, Restrict "Snapshot" to 512-sector drives ** - Firmware returns invalid data in OOB packet - ECC memory error boot message and event log enhancement. - Rebuild time reset - Provide Fastpath as a standard offering for TB based controllers - Ability to power off and on individual HDD - Port latency outlier fixes to FW (from legacy PR137246) - 4K sector support - DDF, DM, Host Interface ** - 4K sector support - iMR, analyze all remaining hard-coded instances of "512" ** - RRB 45 - CLI Reporting of TMM VPD CSETActivities - DDF rev is not updated properly when both 4K and 512 drives are present ** - MR2208 JBOD function can't handle the UNC error of SATA disk - MR Controller Rejects Vendor Unique SCSI Command - Double media error getting corrected during check consistency - Ctrl+R- Ctrl+R BIOS hangs while hot plug of 2 enclosures with more than 32 drives - [MR5.4] CacheCade: ECC/Medium/Unrecoverable read errors handling Enhancement - CC2.1_RA_Support : Data Integrity issue may happen upon creating WB CCVD during Cache Flush - Sequential Read performance is less on CacheCade associated LD's. - Adjusted the USB phy boost value for the OEM controllers with SubDevice IDs between 3510 and 3515. - IO integrity error seen after Source VD associated with CacheCade VD is forcibly unblocked - During rebuild on PRL11 CacheCade VD and rebuild on RAID6 Source VD IO integrity error is seen. - BBU Charging gets disabled when Transparent Relearn fails to start due to low capacity - SCSI Pass-Through to SAS SSD returns data but disk reported medium error - Foreign config import failed from MR to iMR on Solaris 11x86 - Assertion failure in ../../raid/raidpci.c at line 10011 , while running IO with medium errors on arrays. - reading SATA IDENT information using STP_Passthru doesn't work with latest FW - Continues PR 2nd time on Raid 1 and then delete VD and reboot system cause debugger to continues loop and want to run PR - Disk missing sporadically during reboot of OEM - Auto Foreign import fails when controller is booted with pinned cache. - Power loop cycle test on a non DIF drive connected to LSI controller caused fatal firmware error - Significant drop in Sequenial read performance with Read Ahead policy - When a Cachecade PD marked as missing is reused to make Cachecade VD IO integrity error is observed. - If the hotspare was spun down, the copyback after a drive failure wouldn't always start. - Wrong event generated "Reminder: Potential non-optimal configuration due to drive PD xx(e0xfc/sx) commissioned.. - "Assertion failure in ../../raid/mem.c at line 281" on issuing "adpdiag" from megacli-dos - TFM modules with dirty data can cause the controller to hang during boot when transported to another controller - The reliability and error recovery of the SuperCap firmware was improved. - If a correctable ECC error occurred during a cache offload, the CPU would crash, resulting in a data loss - VD becomes WT with a good & new Super Cap on boot - (multiple) Megacli64 error in deadlock state - Timed critical boot message under UEFI mode not showing - Firmware blocked firmware download to interposer - NCQ support is disabled in FW - Data Integrity issue may happen upon creating WB CCVD during Cache Flush - Adjusted the USB phy boost value for the OEM controllers with SubDevice IDs between 3510 and 3515. - GHS drives changed to unconfigured good after OCR / System reboot scenario's - BMC see clock stetching on I2C bus - MR Controller Rejects Vendor Unique SCSI Command - Copyback was successful when the block sizes did not match - [MR5.4] CacheCade: ECC/Medium/Unrecoverable read errors handling Enhancement - FW halts when you have pinned cache and remove VD form the configuration. - Defect fix for 4 K drives Foreign configuration import. - The reliability and error recovery of the SuperCap firmware was improved. - Timeout when creating a hotspare - reading SATA IDENT information using STP_Passthru doesn't work with latest FW - Disk missing sporadically during reboot of OEM - MR: VD created in IR controller comes as UG when connected. - Defect fix for 4K configuration record updation is not happening with 4k drives ** - Firmware asserted at raid/cache.c at line 3661 when VDs are offline - (multiple) Megacli64 error in deadlock state WebBIOS - 6.1-65-e_65-Rel - In EFI WebBIOS with CC running on a R1 when 1 PD is removed EFI WebBIOS still shows that CC is in progress - Controller breaks into Megamon when clicking on the enclosure link in WebBIOS NVDATA - MR2.1304.03-0117 - Degraded performance comparison With the latest MR 5.3 -MR_3.190.25.1887 Hii - 03.02.08.00 - HII doesn not allow user to use the remain free capacity to configure additional VD for R50/R10. - MR 6.1 HII: empty warning prompt is given when creating a CacheCade VD with forced writeback option BIOS - 5.42.00 WebBIOS - 6.1-65-e_65-Rel PCLI - 05.07-00 BootBlock - 2.05.00.00-0010 Common BootBlock - 07.26.13.219 Package 23.12.0-0013 Firmware - 3.240.25-2382 - Coverity issues fix - Sequential Read performance is less on CacheCade associated LD's. - Firmware returns invalid data in OOB packet - Double media error getting corrected during check consistency - [MR5.4] CacheCade: ECC/Medium/Unrecoverable read errors handling Enhancement - Significant drop in Sequenial read performance with Read Ahead policy - The reliability and error recovery of the SuperCap firmware was improved. - Disk missing sporadically during reboot of Puma3 - Adjusted the USB phy boost value for the Mars controllers with SubDevice IDs between 3510 and 3515. - NCQ support is disabled in FW - Athena Rack BMC see clock stetching on I2C bus - Timeout in CIMC when creating a hotspare - CC2.1_RA_Support : Data Corruption upon creating WB CCVD during Cache Flush - reading SATA IDENT information using STP_Passthru doesn't work with latest - Firmware blocked firmware download to interposer BIOS - 5.42.00 - Extremely long delay when the controller POST in Legacy mode - BIOS build date field is empty and build date is displayed as BIOS build time in SLT. - OpROM not getting relocated to runtime segment if the segment address is 0xC0000 - Handle BT750 when B0 and D1 controller is present in HAMR system - HAMR: BIOS to have a logic to filter CCVD and report Remote VD count at OpROM POST time - FW Version number Truncated by one digit in OpROM POST screen - BIOS: Provide scratch segment and populate info to assist Ctrl R to load latest host - Update PERC9 Sub System Device Ids and the corresponding BBS strings. - Retry read capacity if scsi status is not success - MR HWR OpROM BIOS : OOB (BMC) function corrupts EBDA area used by other server function Hii - 03.02.02.00 - HII hangs when trying to enter Configuration Management while in Safe Mode - HII message for Safe Mode is not clear - HEFU: Controller Status should reflect safe mode + dont log debug messages in serial port UEFI_Driver - 0x05270000 WebBIOS - 6.1-62-e_62-Rel - Wrong spanned drive group size is displayed by Web bios(Ctrl-H) PCLI - 05.07.00 FCODE - 4.12.05.00 NVDATA - MR2.1304.03-0118 - Added a subOEM 8 version of the AlcorTU 9273 controller and a subOEM 3 version of the Procyon 9290 controller - Degraded performance comparison With the latest MR 5.3 -MR_3.190.25.1887 between Phase -3 Gemini Vs Phase -1 Gemini BootBlock - 2.05.00.00-0010 Ctrl-R - 4.02-0001 BootBlockCommon - 07.26.13.219 ROMENV - 1.08 Package v23.11.0-0021 Firmware 3.230.05-2100 - Repeated power cycling the enclosure with interposers results in drives not detecting - While executing path-failover test with an SATA-SSD drive behind an interposer, the device is marked failed - Drive not Foreign when pulling drive from VD, reinserting, and changing to UG Hii 03.00.06.00 - HII Create Virtual Drive help file typo - HII displays Supercap capacity values in mAh instead of Joules like all other applications - MR, in HII the learn time shows as 8hours for catera flatwood controller UEFI Driver 0x05240000 BIOS 5.38.00 - MR HWR OpROM BIOS : OOB (BMC) function corrupts EBDA area used by other server function PCLI 05.07.00 - No controller properties for Online FW Update in MegaCLI Bootblock rel-2.05.00.00-0010 - SAS2208 FW MR 5.4 posting a "91" error code FW 23.9.0-015 WebBIOS 6.1-60-e_60-Rel - 5.5 FW 0003/1078 FW 11.0.1-0048\When 1078 controller has message the config is missing EFI webBIOS comes up blank - When creating a Global HSP, it is showing an SSD Drive group as being FDE - WebBIOS displaying wrong info for missing PDs when FDE drives are connected to controller NVData 2.1301.03-0115 MR_SAS_Ctrl-R 4.02-0001 Common BootBlock v07.26.13.219 v23.9.0-0018 - Drives dropped when flashing FW back from MR5.3 to 11M08 and FW crashes with TLB error - BGI does not correct ECC medium errors on 2nd arm of Raid 10 array - Cache offload would not work when a USB debugger was attached - Controller (Alcor-S with OEM PCI id's) is running into a Machine Check loop during copyback test. - Foreign config after reboot with some drives. - MR5.4 FW loses its time settings after OCR - SES device is not found during cable pull testing - Firmware assertion failure during power-cycle test - RAID Member disks state changed to (foreign) online and still can access. - SAS2208 ROMB LD Rebuild suspend/resume issue - MR HWR OpROM BIOS : OOB (BMC) function corrupts EBDA area used by other server function. - BIOS should check pMRCtrlInfo ->maxHANodes with > 1 to determine HAMR v23.9.0-0015 - MR FCODE Driver release - TB BIOS 5.37.00 - HEFU HII Release 2.05.00 for 2208 - Singed UEFI Driver 0x05180000 (for Win 8 Secure Boot) - MR 5.3 Bootblock rel-2.05.00.00-0009 - MR 5.4 NVData Release: MR Version 2.1209.03-0112; iMR Version 2.1209.04-0112 - MR_WebBIOS_MR5.4_2208_release_version_6.1-49-e_49-Rel - MR_SAS_Ctrl-R_MR5.4_2208_release_version_4.02-0001 - HWR_LSI_MR_5.4_PCLI_Release_Version_5.05.03 - Release 5.2: MegaRAID GCA Common BootBlock v07.26.13.219 - 11M06 TB ROMENV Release - Firmware does not backup data during power fail with SuperCap. -Serious performance issue found in the latest public official LSI 9285-8e MegaRAID firmware 1776(small sequential reads perf) -System failed to boot with enableJBOD feature with B0 board -HAMR: BIOS is firing LD list query with query type exposed to boot instead of cluster access -Applying changes in Automatic Learn Cycle Properties ends up with "Requested Command is invalid" -Help is missing for some of the fields. -OEM adapters card may training to PCIe Gen2 for certain slots -Bootblock is using NVRAM data even if NVRAM is uninitialized -Remaining capacity is coming 0 from FW. -Battery Firmware vesion(MR_BBU_DESIGN_INFO.moduleVersion) is coming as Null -WebBIOS does not warn user before importing PI enabled VD on PI disabled controller. -WebBIOS reports incorrect number of foreign configs during "Scan Devices" -Preboot apps have to change load address change because of FW changes -WebBIOS should not allow RLM for protected VDs with non-PI drives. -WebBIOS does not show "Day" for Next learn cycle time in battery page. And issue with safe mode. -WebBIOS displays SSD association screen for Secured and Protected VDs (Virtual drive table is empty). v23.7.0-0038 - R50 DIF VD with multiple rebuilds reports - ref mismatch - TB D1 controllers may train to PCIe Gen2 in certain systems v23.7.0-0037 - RAID features are lost because of errors while accesing TSOC using an old firmware (11M08) - Pulling cable when maintainpdfailhistory=1 create wrong state in arrays. - Memory test does not execute when performing FW diagnostics. - MFC variable enableSSCWB was not getting updated when updated via megaSCU - Dont log capacity change event post rebuild completion. - Log commission event only if Rebuild will start on the PD. - Clean up bad block list during background init/check consistency failure - SATA BBM list corruption - Stressing test on degrade raid with drives or rebuilding on drives will cause firmware hang v23.7.0-0033 - Option ROM hang on some systems with Quiet Boot enabled v23.7.0-0031 - Enabled support for SSD drive cache enable/disable - Clean up bad block list during background init/check consistency failure - SATA BBM list corruption - Stressing test on degrade raid with drives or rebuilding on drives will cause firmware hang - T-bolt firmware : makes unconfigured bad (foreign) to unconfigured bad on reboot. - cannot make the CacheCade configured PD as unconfigured bad even pulling it out during system online. - Hot Spare lost after FW update v23.7.0-0029 - Stressing test on degrade raid with UNC drives or rebuilding on UNC drives will cause firmware hang - Firmware reports device initialization completion status to be greater than 100% at startup - Split large bitmap reads into pieces - USB Cacheoffload restore fails after multiple power cycle. - When secure foreign drive is present, VD creation fails because FW become unresponsive - Check for the presence of PD before writing the data arms of a protected LD during BGI - FW asserts in CacheMemAllocForPrebootApps() when memory is allocated twice by BIOS. - USB Cacheoffload restore fails after multiple power cycle on a Madison controller - Querying SMART / PFA Status Returns All Zeros in Sense Data v23.5.0-0027 - Save repository information in NVRAM - MegaRAID FW could result in a deadlock condition when offloading data to USB cache module after a system power failure and a power restore condition before offload operation could be completed. - When windows are freed, re-initialize those fields because freed windows can be allocated to other commands in case of window crunch scenario. - iMR-f/w hang at Waiting for Expansion ROM to load. - Skip spare check for R0 cachecade vd. - Change protected R6 secure erase behavior - Remove faulty check - If LD is in offline state then dont initate flush. Delete the VD. - DATA TLB error seen during cache offload while performing automated system power cycling test with cache present. v23.4.1-0028 - FW_CacheCade_2.1_Integration - Hot Spare alarm sounding after 11M08 Phase 4 firmware update - FW hit MonTask: line 1221 in file ../../raid/1078dma.c when run I/O and create partition - MonTask: line 6613 in file ../../ssd/ssd_cache_fw.c during creation of SSCD. - while running IOs on VD using a cachecade WB VD FW goes to megamon - Data integrity while running I/O's on R0 VD with HSP kicking in for rebuild on R1 WB SSCVD v23.2.1-0033 - Reset disablebatterywarning in ctrl properties only if battery is present - Fix for offload incompletion due to delaySOD env stamping - Double dip with deeply depleted Supercap failure ?Fix - Adding PCI register initialization to PCI re init for cache offload v23.2.1-0023 (DFCT) Global activity LED does not work at all from 1403 or later. (DFCT) Cache Vault - No "Battery Removed" event when SuperCap is removed. v23.2.1-0021 (DFCT) HWR: 11M08: Event message is misleading Patrol Read corrected medium error on PD (DFCT) PKG 1400/Controller RMS25AB080 C1 with 1GB TMMB/After pinning the cache on an R1, hitting reset, the cache is lost. v23.1.1-0004 (DFCT) FW: CacheCade VD cleared event log has a wrong VD number. (DFCT) DSW II: hotspare Power state change during CC is incorrect (DFCT) SMI-S: The value of CurrentCachePolicy becomes invalid after changing Logical Drive cache mode. (DFCT) FUA bit should be set for the write i/o in case rebuild write cache enable (DFCT) Revert back the original rebuild progress logic (DFCT) Hit Kill Adapter During Heavy I/O & Rebuild (DFCT) HWR: LDBBM does not consistently handle medium errors during R6 rebuild (DFCT) FW: Snapshot roll back causes FW fatal error : Linu 278 in ../../raid/1078int.c. (DFCT) PEReplyDelay value can't be changed with NVDATA value (DFCT) WLK1.6 Read Capacity 16 Unit Test - SCSI Compliance - FAILS (DFCT) killadapter when running I/O on SUN sparc (CR) WebBIOS : Do not let WebBIOS to display "Chip Temperature (Celsius)". (CR) FW Re-activate the user option to enable Patrol Read on SSD. v21.1.1-0111 (DFCT) Dummy Defect to complete 10M12 patch stream tasks (DFCT) fw hit montask at pd.c when rebuilding from raid 6 (DFCT) Porting fix for the defect - Kill Adapter after 62 cycles of cable pull/push with I/O (DFCT) I/O miscompares when issue OCR. (DFCT) 10M09 to 10M12_patch merge issue and compiler error (DFCT) Return status code 'Success' to certain obsolete SCSI commands (DFCT) Liberator FW 10M09 cause system (sles11sp1/rhel6) reset while lspci -vvxxx is used (DFCT) sscd show 0 byte in debugger and MSM (DFCT) Application has advanced software options listed. This needs to be removed for Catera OEM (DFCT) Drive comes up as unconfigured bad while running power cycle and error injection script (DFCT) ekms bios is not enable (DFCT) Inconsistent drive state after drives are changed to different slots. (DFCT) Clear configured with SSC degraded causing FW went to mon_tsk() (DFCT) With multipath setting, found data miscompare while IOs across 2 enclosures (DFCT) FW doesnt detect the iBBU08 if it is remotely mounting with Farmington controller (DFCT) AI after code review on 03-02-2011 (DFCT) DateOfFirstuse is Incorrectly Causing BBU Deep Discharge Requirement (DFCT) Controller hit montask during BGI (DFCT) Configured PDs become not supported PDs, LDs dropping offline. (DFCT) Liberator FW 10M09 cause system (sles11sp1/rhel6) reset while lspci -vvxxx is used (DFCT) Controller reports "phy is bad" for single port with any SATA device (DFCT) HSP commissioned alarm beep goes away after reboot (DFCT) Port fixes from Perc8 (DFCT) port 2TB error handling changes (DFCT) FW aborts the recovery resulting SES not responding (DFCT) Provide mechanism to bypass settings delayPOST and envDelaySOD (CR) Deliver HII in Q1 2011 Liberator maintenance v21.1.1-0110 (DFCT) Enable Redirect Path in FW for FP disabled case v21.1.1-0105 - Initial release *Third-party trademarks are the property of their respective owners.