This release note and the software that accompanies it are copyright (c) 2014, Intel Corporation or its suppliers, and may only be installed and used in accordance with the license that accompanies the software. This Software is furnished under license and may only be used or copied in accordance with the terms of that license. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. The Software is subject to change without notice, and should not be construed as a commitment by Intel Corporation or its suppliers to market, license, sell or support any product or technology. Unless otherwise provided for in the license under which this Software is provided, the Software is provided AS IS, with no warranties of any kind, express or implied. Except as expressly permitted by the Software license, neither Intel Corporation nor its suppliers assumes any responsibility or liability for any errors or inaccuracies that may appear herein. Except as expressly permitted by the Software license, no part of the Software may be reproduced, stored in a retrieval system, transmitted in any form, or distributed by any means without the express written consent of Intel Corporation. ========================== Supported RAID Controllers ========================== This download supports Intel(R) RAID controllers using IMR software stack (RS3WC080, RMS3HC080, RS3YC, RS3LC), please verify that this utility has been tested with the RAID card you have chosen to use by checking the drivers web page for your controller at http://support.intel.com. =================== Package Information =================== Flash package = v24.6.0-0030 ========== Attention! ========== Intel recommends to loading Factory Default setting after the firmware upgrade which will not affect data on any existing array. To do so: 1. Reboot the system and login to the RAID BIOS Console. 2. Select the controller and select 'Adapter Properties'->'Next' 3. Set the 'Set Factory Defaults' setting to 'Yes' and submit the change. 4. Reboot the system (the default settings are applied). 5. Re-configure to the desired settings in RAID Web Console2. ================== Known Restrictions ================== 1) This download does NOT support EFI v1.1 environment. Please use the EFI shell command “ver" which will display the EFI version, to identify the EFI version. 2) When 2 or more VDs are created, VD cache settings must be the same. ======================= Contents on the package ======================= The following files are included in this zip: Name: Description: COPYING.NEWLIB.txt License Agreement 3008-IMR_FWPKG-v24.6.0-0030_readme.txt This file iMR65p.rom Firmware binary License_v2.pdf License Agreement update.nsh UEFI firmware update batch file StorCLI\* StorCLI command line utilities (See the StorCLI release notes file for details regarding StorCLI) ========================== Installation instructions: ========================== UEFI shell instructions for updating RAID Firmware: ----------------- 1. Download and extract all files to a USB flash drive. 2. Boot the target system to EFI shell. 3. Change directory to the local drive and directory containing the flash update files and the firmware image file. 4. Type "update.nsh" and press to execute the command 5. Wait for the flash to complete. Do NOT reboot the system during the update. You can also use RAID Web Console 2 or OS version of StorCLI to update the RAID firmware. For more detail, please refer to the Intel(R) RAID Software User's Guide. ============================= Package Details/Fixes/Updates ============================= Firmware Package:24.6.0-0030 (MR 6.5 Point Release) Firmware 4.260.01-3883 SCGCQ00775267 - (Closed) - 3008 iMR - DPA extended capabilities bits structure is invalid SCGCQ00783613 - (Closed) - Firmware logs are not dumped to flash during device discovery phase SCGCQ00655162 - (Port_Not_Required) - Failed LED on 10HD BP does not light correctly for a bad drive SCGCQ00772911 - (Port_Complete) - Firmware indicating that PD can be spun down even in online state SCGCQ00783159 - (Port_Complete) - GPIO 24-31 is should be low when activity is going on drive SCGCQ00783186 - (Port_Complete) - Behavior change when FW hit fault code 0x81 (uncorrectable ECC error) SCGCQ00788250 - (Port_Complete) - Identify FDE drive compliant to Opal spec and mark them as non-FDE drive SCGCQ00775196 - (Port_Complete) - Workaround for Hardware Issue - SCGCQ00632364 SCGCQ00779356 - (Port_Complete) - Virtual Disk GUID field changes when a VD is moved. The LUID is supposed to be unique and invariant. SCGCQ00783180 - (Port_Complete) - The field "expanderFwVersion=" is not populated under "ctrl info" in megamon SCGCQ00788252 - (Port_Complete) - Need MR 6.3 iMR Firmware Capable of Updating the SBR on a Customer Board in the Field SCGCQ00788283 - (Port_Complete) - Expander reports wrong active firmware version SCGCQ00783171 - (Port_Complete) - If diagnostic test fails on the copyback drive the FW does not allow a Recon, Copyback and CC on the same VD. SCGCQ00789243 - (Port_Complete) - OEM Expander (Truchas Valley) reporting temperature sensor error ROMENV 1.09 BootBlock 3.02.00.00-0001 NVDATA 3.1408.01-0010 SCGCQ00762970 - (Port_Complete) - Customer needs NVDATA changes for PHY-to-SLOT mapping Various other changes for specific OEMs. UEFI_Driver 0x06090701 (SIGNED) SCGCQ00759757 - (Closed) - Direction bit is not set for READ CAPACITY commands Hii v03.10.09.01(SIGNED) SCGCQ00769319 - (Closed) - The last digit for Expander FW version is truncated FCODE 4.16.08.00 BIOS 6.20.04.1 SCGCQ00769239 - (Closed) - Don't issue REAID I/O on the 4K JBOD Ctrl-R 5.07-0006 PCLI 1.07.05 Firmware Package:24.6.0-0023 (MR 6.5) Firmware 4.260.01-3736 SCGCQ00584299 - (Closed) - R5/R6 SSD 4K Random Write IOps lower than expected (at a QD fo 256) SCGCQ00609808 - (Closed) - R0, R5, R6 read bandwidth drops abruptly at 256K block size with 24Dr SATA SSD configuration SCGCQ00630717 - (Closed) - SED: Montask fdeSM.c seen when using previously locked FDE drives. SCGCQ00649088 - (Closed) - Continuous Message in log "logGet: Found invalid event at fc570abc" SCGCQ00692488 - (Closed) - Assertion failure while running sequential reads on read ahead volume SCGCQ00693153 - (Closed) - The VDs when migrated from 6.4 to 6.5 will no longer be hidden from OS SCGCQ00699179 - (Closed) - Head of Queue Functionality is not getting executed SCGCQ00701317 - (Closed) - Change deviceExposure value from MegaMon for better debugging SCGCQ00704603 - (Closed) - Aspen firmware will crash or hang on unsupport cmd SCGCQ00705240 - (Closed) - Not able to set OEM value apart from 6 SCGCQ00705302 - (Closed) - MR 6.5 FW:returning status failure while associating raid arrays to cachcade array. SCGCQ00710588 - (Closed) - MR6.5:Caching not happening after rebuild completed on R1 CCVD with BGIO's running on SVD SCGCQ00715282 - (Closed) - initialize the tempsensor to default full mode on restart SCGCQ00715395 - (Closed) - Virtual drive missing after online controller reset SCGCQ00715413 - (Closed) - Controller resets to its earlier time after OCR SCGCQ00719591 - (Closed) - Cannot change drive state while removing & inserting drive during recon and cannot start manual rebuild after recon. SCGCQ00724968 - (Closed) - Rebuild not starting on SSD, when Enclosure PD’s[used for SVD] and SSD's[used for CCVD] are foreign imported together SCGCQ00725070 - (Closed) - I/Os continue to run after hiding the VD for second time SCGCQ00726288 - (Closed) - New CMD_BLOCK added to initialize temperature sensor SCGCQ00732059 - (Closed) - Battery Learn Cycle is not getting initiated after CLBAD set for more than 3 mins. SCGCQ00734705 - (Closed) - Data TLB error seen on switching from FPM to HPM with OCR SCGCQ00643509 - (Closed) - Incorrect Max number of disks shown by LSA for Spanned Raid levels in IMR controller during Volume creation. SCGCQ00685640 - (Closed) - 3108 MR solution reports supercap is 254 C when actual ambient temp is -2 C SCGCQ00695428 - (Closed) - FW crashes during OS installation SCGCQ00696619 - (Closed) - MR 6.5 : Firmware breaks to Montask on line ../../raid/cache.c SCGCQ00696625 - (Closed) - PSOD observed while changing controller property 'enableJBOD' to 1. SCGCQ00701744 - (Closed) - FW got hung up during error handling of sence 0B/47/xx SCGCQ00704600 - (Closed) - Aspen firmware will crash when get to the end of "next devhandle" SCGCQ00705255 - (Closed) - Average Read response time for RAID 1 configuration is never calculated SCGCQ00712125 - (Closed) - iMR:6.5-Exception in core 0 is seen when drives are spun down and an ocr is triggered SCGCQ00716517 - (Closed) - MR6.5_FW: Pinned cache is not Flushing after second Foriegn Import while PD is removed in First Foriegn Import SCGCQ00725087 - (Closed) - Head Of Queue leads to negative delays between rebuild cycles SCGCQ00731286 - (Closed) - Core 0 exception in line 243 in file ../raid.c encountered when GG update fails with Stress IOs on all WB VDs SCGCQ00736509 - (Closed) - "Restore done successfully" prints available in firmware logs even after cache data is lost. SCGCQ00736863 - (Closed) - Inconsistent values reported for Write response times for RAID 1 VD's with HOQ and no IO SCGCQ00742024 - (Closed) - Disabling Control of HOQ Rebuild through applications SCGCQ00649094 - (Closed) - SSD VD association to CC VD through storcli shows success but actually it is not associated SCGCQ00692393 - (Closed) - LmidFifo Isr observed during drive pull with IO's on R5 VD SCGCQ00696256 - (Closed) - FW hit the Montask while running the TASIO SCGCQ00724961 - (Closed) - improper setting of targetSpeed in PCI link control 2 register to change pci link rate resulted in adapter reset. SCGCQ00713615 - (Closed) - MR6.4 random write throughput on 24SATA SSD R5/R6 configuration regressed compared to MR6.3 SCGCQ00664261 - (Closed) - Port CQ Defect 421011 IOP: Asynchronous reset may cause system reset and PCIe Link Down SCGCQ00688064 - (Closed) - Foreign configuration import is successful but drive state still remains unconbad foreign during copyback SCGCQ00704310 - (Closed) - Disable DCR ERR LOG interrupt to fix DIS issue SCGCQ00712480 - (Closed) - Bypass cache for sequential writes which are greater than or equal to 128 KB SCGCQ00703189 - (Closed) - "Prepare For Removal" does not work on a PD when drive erase is in progress SCGCQ00700829 - (Closed) - MPI 2.5: BIOS Page 1 additions SCGCQ00685820 - (Closed) - MPI 2.5: distribute Target Command Buffers Received across multiple reply queues SCGCQ00683317 - (Closed) - Dirty Lba sorting is removed for fully SSD RAID Arrays. SCGCQ00682656 - (Closed) - Use region lock engine's capability to release local message identifier along with releasing region locks SCGCQ00634798 - (Closed) - Enable FastPath for all LSI Controllers SCGCQ00642226 - (Implemented) - Implement HEAD OF QUEUE to improve Rebuild performance over MR controllers SCGCQ00696862 - (Closed) - Ability to Support VPD Information in MR 6.3 SCGCQ00652300 - (Closed) - MegaRAID power throttling implementation SCGCQ00650087 - (Closed) - Implemention to report HDD Temperature for Drives which does not support exceptional log page SCGCQ00656611 - (Implemented) - Add ability to take a VD offline, bring back VD online SCGCQ00667140 - (Port_Complete) - OEM Additional update required ontop of CritCom 66:PCIe SERDES parameter setting updates SCGCQ00675820 - (Port_Complete) - Updated long term WA for PPC errata #46 SCGCQ00680739 - (Port_Complete) - Custom KeyGen Solution SCGCQ00682665 - (Port_Complete) - Cache offload failure with pinned cache on R5 VD SCGCQ00685986 - (Port_Complete) - Add better debugging functionality for Alarm related field issues SCGCQ00687878 - (Port_Complete) - Ctrl+R is not enabled after downgrade and upgrade FW SCGCQ00692232 - (Port_Complete) - OEM Data Corruption is taking place on Windows OS installed on top of ESX 5.5 U1 OS. SCGCQ00695333 - (Port_Complete) - Serial prints getting jumbled up due to print message inside spourious interrupt handler. SCGCQ00695385 - (Port_Complete) - 4K VDs missing after server reboot SCGCQ00695393 - (Port_Complete) - Postpone CC on boot for 5 minutes SCGCQ00702593 - (Port_Complete) - Issue a complete Gas Gauge reset on every boot SCGCQ00703177 - (Port_Complete) - Update Gas Guage Safety Status register bit positions SCGCQ00704303 - (Port_Complete) - Implemented Gas gauge FW update functionality . SCGCQ00710111 - (Port_Complete) - Reduce the monitoring time of CL (Capacitor Learning) flag in BQ33100 Operation Status register to 5Sec when a learn command is issued. SCGCQ00711812 - (Port_Complete) - Change SuperCap auto learn cycle period to 27 days and 22 hours. SCGCQ00712593 - (Port_Complete) - Prowl x24 not spinning up all disks (1.8 SSDs) SCGCQ00713099 - (Port_Complete) - OEM Data Corruption is taking place on Windows OS installed on top of ESX 5.5 U1 OS. SCGCQ00714527 - (Port_Complete) - Internal development defect to correct Module version validation logic for Gas Gauge firmware update SCGCQ00719724 - (Port_Complete) - FW doesn't do an Online Firmware Update (OFU) after a successful Gas Gauge firmware update . SCGCQ00722959 - (Ready) - Higher Jetstress average database writes latency SCGCQ00734987 - (Port_Complete) - The cache policy of Virtual Drives(VDs) do not change to Write-Through(WT) if FAULT is asserted and there is no indication in BQ33100 Safety Status register. SCGCQ00671448 - (Port_Complete) - ONFI: To properly handle the OCR case with RESET Status Register. SCGCQ00673627 - (Port_Complete) - Supercap properties reports wrong in storcli SCGCQ00687692 - (Port_Complete) - Foreign configuration import failure for spanned array with pinned cache SCGCQ00688780 - (Port_Complete) - Enable FastPath for all LSI Controllers SCGCQ00692233 - (Port_Complete) - Make sure numbers show up in Ctrl_R for drive Ids when drives connected through passive backplane SCGCQ00693961 - (Port_Complete) - [R630] Failed LED on 10HD BP does not light correctly SCGCQ00706922 - (Port_Complete) - Cache offload not triggered on few servers rarely SCGCQ00714523 - (Port_Complete) - Performing reboot immediately after updating the Gas Gauge (before learn completes) results in the FW reporting an update error on every subsequent boot. SCGCQ00723647 - (Port_Complete) - Flashing wrong Gas Gauge image (or any bad image) will force VDs to WT(Write Through) and fail and there is no path back to WB other than rebooting SCGCQ00757273 - (Port_Complete) - Performance degrade up to 35% in Write Back enabled 100% Random Writes as compared to MR 6.3 FW SCGCQ00679766 - (Port_Complete) - MR 6.4 : MonTask: line 4699 in file ../../raid/ld.c seen on iMR FW during boot to OS with R0 and PRL11 VD SCGCQ00695622 - (Port_Complete) - PPC exception seen during reboot test case on a VD SCGCQ00696014 - (Port_Complete) - PERC Data Corruption is taking place on Windows OS installed on top of ESX 5.5 U1 OS. SCGCQ00711847 - (Port_Complete) - Cache offload not triggered on few servers rarely SCGCQ00719701 - (Port_Complete) - When supercap learn is pending (overdue) at boot, exposure time in WB mode is seen for up to 1 minute 5 seconds. SCGCQ00730750 - (Port_Complete) - Flashing wrong Gas Gauge FW will succeed if flashed after good Gas Gauge FW is flashed and before the learn starts SCGCQ00695390 - (Port_Complete) - Serial prints getting jumbled up due to print message inside spourious interrupt handler. SCGCQ00703187 - (Port_Complete) - When we attempt to retrieve iMR Thunderbolt controller firmware logs using an application, we see some lines that are wrapped without starting on a new line. SCGCQ00704221 - (Port_Complete) - CSET: Continuous Message in log "logGet: Found invalid event at fc570abc" - (SCGCQ00649088) SCGCQ00716842 - (Port_Complete) - Preventing a specific supercap error message being printed in term log SCGCQ00734876 - (Port_Complete) - Few un-acceptable prints in serial log. SCGCQ00678585 - (Port_Complete) - Controller in JBOD mode is allowing a PD designated as a Hot Spare to be a configured via OOB as the boot drive SCGCQ00693962 - (Port_Complete) - RAID 5 Random Writes on SSDs SCGCQ00695613 - (Port_Complete) - 4K VDs missing after server reboot SCGCQ00700868 - (Port_Complete) - When we attempt to retrieve iMR Thunderbolt controller firmware logs using an application, we see some lines that are wrappedwithout starting on a new line. ROMENV 1.09 BootBlock 3.02.00.00-0001 NVDATA 3.1408.01-0007 Numerous changes for specific customers UEFI_Driver 0x06090700 (SIGNED) SCGCQ00691044 - (Closed) - Code refactor effort: Hii Image buffer clean-up SCGCQ00688789 - (Closed) - DHP: Remove default value from numeric primitive that is present under suppressif SCGCQ00732773 - (Closed) - UEFI Driver: If the platform contains UEFI Spec Rev < than 2.3.0, then don't HII SCGCQ00756810 - (Closed) - PKG 9 HII form/When you have a a critical message such as missing VDs, after select "C" , it will show an assert SCGCQ00726723 - (Closed) - Ext/SCSI PassThru: UEFI Driver not filling direction flag correctly for Read SCGCQ00696656 - (Closed) - Update Mbox value for 240VD Support SCGCQ00650086 - (Implemented) - UEFI Driver UDK2010 complaince SCGCQ00688987 - (Port_Complete) - Don't let user boot to OS until user discards dirty cache SCGCQ00736761 - (Port_Complete) - Return health status failed if we have returned device error from Start() SCGCQ00756861 - (Port_Complete) - ControllerInfo[CtrlIndex].ControllerHandle got initialized incorrectly or too early SCGCQ00695249 - (Port_Complete) - Safe guard: Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status SCGCQ00716623 - (Port_Complete) - For OEM change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00716622 - (Port_Complete) - For OEM dont free the host memory during disconnect/unload process Hii v03.10.09.00(SIGNED) SCGCQ00689437 - (Closed) - Schedule consistency check gives an error message on Apply changes SCGCQ00692849 - (Closed) - When Controller is in Safe Mode don't remove UCM formset SCGCQ00696506 - (Closed) - Grammaical errors in HII warning message during FW Flash. SCGCQ00691938 - (Closed) - HII: Return device error when MR_DCMD_CTRL_PROPERTIES_SET fails. SCGCQ00700304 - (Closed) - MR_240VD:System fails to boot into SETUP[F2] and displays blank screen with 160 and 240 VDs SCGCQ00716628 - (Closed) - To Handle Code collab review Defect for SCGCQ00700199 SCGCQ00700199 - (Closed) - After selcting Discard pinned Cache from Controller Management, Form will be taken to Cache and Memory after success. SCGCQ00702200 - (Closed) - Firmware Update feature fails to update firmware in HII SCGCQ00709543 - (Closed) - gHiiDriver.ExtLDSupport should be Filled with appropriate value before it's used SCGCQ00702196 - (Closed) - Asserts seen before loading HII SCGCQ00704309 - (Closed) - HII: Question value mismatch message seen in Enclosure Management screen. SCGCQ00714530 - (Closed) - HII: Firmware Update - On selecting empty folder, hang is seen. SCGCQ00731567 - (Closed) - use hwPresent.memory to determine iMR SCGCQ00706817 - (Closed) - MR_240VD: Virtual Drive properties[Read/Write/IO Policy] gets changed after VD creation from HII SCGCQ00710064 - (Closed) - Handline code collaborator Defect for SCGCQ00709543 SCGCQ00716636 - (Closed) - Incomplete SAS Address SCGCQ00705577 - (Closed) - Unable to select the second enlcosure when multiple enclosures are connected to a controller . SCGCQ00715566 - (Closed) - . SCGCQ00723184 - (Closed) - Capacity Allocation in drive group properties is inappropriate SCGCQ00730496 - (Closed) - MR: HII gives the option to set -head of queue for raid 0 SCGCQ00742103 - (Closed) - Remove Head Of Queue rebuild feature SCGCQ00704216 - (Closed) - HII hangs on selecting "View Drive Group Properties" SCGCQ00734447 - (Closed) - Patrol read prop page gives an error message on Apply changes SCGCQ00642228 - (Implemented) - Implement Head of Queue drive rebuild for MegaRAID controllers SCGCQ00650085 - (Implemented) - HEFU HII UDK2010 complaince SCGCQ00689070 - (Closed) - MR 6.2- Negative test HII browser- Mixing unsupported drives message needs update SCGCQ00664753 - (Closed) - Ability to enable/disable JBOD mode in HII & CTRL-R SCGCQ00656614 - (Closed) - Add ability to take a VD offline, bring back VD online SCGCQ00688454 - (Implemented) - HEFU HII UDK2010 complaince SCGCQ00695063 - (Port_Complete) - Call UninstallStoreLib when we call StopControllerHiiImpl function SCGCQ00695068 - (Port_Complete) - In HII Create VD option is enabled when resconstruction is in progress (on partial VD) SCGCQ00695072 - (Port_Complete) - H730P- Not showing PD to assign as DHS to R50/ R60 VD if PD is of lesser size than largest PD in V SCGCQ00695223 - (Port_Complete) - OEM 9.1.2 - HII: Contents of few help messages are improper SCGCQ00728678 - (Port_Complete) - Aspen UEFI creating a new VD in a "hole" in the drive group free space, hangs when viewing drive group properties SCGCQ00756855 - (Port_Complete) - Chk the err status for HL_Get_PD_List() and HL_Get_PD_Info in UF002_PrepareData() + check Driver handle if index is valid FCODE 4.16.08.00 BIOS 6.20.04 SCGCQ00720411 - (Closed) - OpROM 240VD: Not able to boot to OS from the VD whose target ID is greater than 128 SCGCQ00455591 - (Closed) - Memory access issue for Mercury when loading Ctrl R SCGCQ00693494 - (Closed) - setting deviceExposure greater than or eaual to 128 will show wrong VD handled by bios SCGCQ00455597 - (Closed) - Memory allocation: Allocate only two 64k SCGCQ00736737 - (Port_Complete) - xprintf display issue when FW reports percentage for device scan SCGCQ00709995 - (Port_Complete) - OEM wants the battery status text in BIOS to change from "missing" to "N/A" for iMR solutions. Ctrl-R 5.07-0006 SCGCQ00720815 - (Closed) - Ctrl+R: and links in Properties Page both redirects to next page and vice versa. SCGCQ00716584 - (Closed) - /c0 show all page are having some incorrectness in controller information SCGCQ00704259 - (Closed) - Firmware Hangs/breaks while creation of RAID1 with GHS SCGCQ00738006 - (Closed) - Incorrectness in the popup for Virtual drive Expansion SCGCQ00712982 - (Closed) - Verify StorCLI warns on destructive operations - R0 with 2 x SED drives Deleted with no warning. SCGCQ00729691 - (Closed) - fault(coredump) observed on executing ./storcli /c1/v63 show all for 64th cachecade VD in ubuntu14.04 SCGCQ00707450 - (Closed) - While creating cachecade vd with one SAS-SSD;Raid 1 option is also enabled SCGCQ00710520 - (Closed) - Ctrl+R_6.5: Incorrectness in Help file generated by pressing F1 SCGCQ00712171 - (Closed) - While creating cachecade vd with one SAS-SSD;Raid 1 option is also enabled SCGCQ00730497 - (Closed) - MR: ctrl-r gives the option to set -head of queue for raid 0 SCGCQ00727409 - (Closed) - CTRL-R:Incorrectness in CTRL Management while launching Manage Link Speed SCGCQ00706013 - (Closed) - VD I/O policy changes from cached to direct when VDs are created from Ctrl-R SCGCQ00725545 - (Closed) - In foreign Config Preview VD Size is coming as NA instead of actual size,when VD state is foreign. SCGCQ00735369 - (Closed) - not able to navigate through "join mirror -choose option" window SCGCQ00730412 - (Closed) - Incorrectness in the popup generated during deletion of Cachecade associated Virtual Drive SCGCQ00742106 - (Closed) - Remove Head Of Queue rebuild feature SCGCQ00731292 - (Closed) - Unable to see PD(s) Count in Cachecade RAID1 w.r.t to Cachecade RAID0 SCGCQ00709969 - (Closed) - Ctrl+R_6.5: Showing incorrectness in Memory Size in Properties Page2 SCGCQ00719102 - (Port_Complete) - Date Created field in storCLI display is incorrect after creating a VD in MSM using SWR versio 1.34 on ALM2-16 SCGCQ00732019 - (Active) - CLI command to access/modify Immediate IO SCGCQ00694663 - (Port_Complete) - Simulator files check-in with changes in new API. SCGCQ00732058 - (Port_Complete) - CLI command to access/modify Drive Activity LED SCGCQ00699269 - (Port_Complete) - storcli is displaying only information of one enclosure when all option is given for phyerrorcounters, on multiple enclosures PCLI 1.07.05 Firmware Package: 24.5.0-0015 (MR 6.4) Firmware 4.250.00-3569 SCGCQ00651356 - (Closed) - Cache offload not triggered on few servers rarely SCGCQ00663028 - (Closed) - Patrol read is in progress even after issuing stop patrol read command through App SCGCQ00669540 - (Closed) - PPC exception seen during reboot test case on a VD SCGCQ00672868 - (Closed) - Firmware crash @line 1266 in file ../../raid/1078dma.c while Clearing the configuration when reconstruction going on. SCGCQ00677415 - (Closed) - Patrol read suspended message continues to appear even after it is stopped SCGCQ00678651 - (Closed) - Firmware breaks into montask at line : 931 in file ../../raid/bladeDMA.c SCGCQ00685276 - (Closed) - Configuration lost on Controller while importing the configuration just as the drives start to show in discovery. SCGCQ00687265 - (Closed) - Exception in Core 0 on rebooting the System while reconstruction is in progress SCGCQ00695573 - (Closed) - Performance degrade up to 35% in Write Back enabled 100% Random Writes as compared to MR 6.3 FW SCGCQ00637612 - (Closed) - eccBucketSize set to threshold value 15 upon changing its value to 0 or 1 SCGCQ00638190 - (Closed) - PD is reported as a 'HSP by storcl64 which is neither DHSP nor GHSP. SCGCQ00644645 - (Closed) - FW Breaks while importing Foreign Config(BS Assertion Failure while flushing the pinned cache) SCGCQ00652759 - (Closed) - set the BBUEnable flag as per the cacheoffload requirement SCGCQ00685001 - (Closed) - patrolread suspended message appears even after resuming it and while progress in PR SCGCQ00604480 - (Closed) - locate behavior will incorrect light some drive LED not located after some loop locate test on 3108 MR+PMC Expander SCGCQ00613357 - (Closed) - Able to perform PD format and PD secure erase operations simultaniously SCGCQ00620701 - (Closed) - All the menu items in MSM such as create VD are highlighted when the controller is in safe mode. SCGCQ00624038 - (Closed) - Changed the order of evaluation to compiler independent SCGCQ00633906 - (Closed) - Disable the HW assisted L3 cache flush prior to offload in case of powerloss. SCGCQ00634405 - (Closed) - Data Misscompare found on Raid 60 when pinned cache is created on Raid 50. SCGCQ00636277 - (Closed) - Battery Retention Test not reporting test result. SCGCQ00642679 - (Closed) - Assertion failure in ../../raid/cache.c at line 2772 SCGCQ00653832 - (Closed) - Delay in OCR with IO timeouts is seen when Security is enabled SCGCQ00658494 - (Closed) - FW issuing false event saying VD policy change from WT to WB even the memory module is bad SCGCQ00664511 - (Closed) - Enable DIS feature in FW SCGCQ00672040 - (Closed) - MonTask: line 7204 in file ../../bbu/onfi.c with power cycle script SCGCQ00673991 - (Closed) - ocr does not trigger after deleting nvram SCGCQ00677803 - (Closed) - Cache offload failure with pinned cache on R5 VD SCGCQ00679787 - (Reworked) - Foreign configuration import is successful but drive state still remains unconbad foreign during copyback - SingleNode SCGCQ00681033 - (Closed) - Assertion in ../../raid/raidscsi.c at line 904 with controller reset while CacheCade toggling for mix of VDs. SCGCQ00630344 - (Closed) - Coverity Integrity Manager tool defect SCGCQ00645801 - (Closed) - Getting Question Value mismatch when entering Controller management screen in HII SCGCQ00655979 - (Closed) - Drive failures observed while issuing a pass through link reset to all phys in a loop SCGCQ00669055 - (Closed) - Hit a MonTask while running overnight learn cycles with OCR every 10mins SCGCQ00669713 - (Closed) - Solid amber LED does not reset on a failed SGPIO slot upon device recovery if locate is on before the drive fails SCGCQ00679180 - (Closed) - Foreign Config fails to import max config SCGCQ00642473 - (Closed) - Jetstress test fails after completion of rebuild SCGCQ00661244 - (Closed) - Mismatch in emulation properties observed on importing VD from foreign configuration SCGCQ00665670 - (Closed) - Join Mirror command with option 2 imports foreign configurations which are not part of broken mirror. SCGCQ00674868 - (Closed) - observed when OS was formatting the VD in which cluster double medium error injected SCGCQ00680326 - (Closed) - Failed import VDs with pinned cache after ONFI tranport SCGCQ00661190 - (Closed) - cache is not getting bypassed for 64 VD;s SCGCQ00671194 - (Closed) - Failed import a R5 VD with pinned cache after ONFI tranport SCGCQ00677411 - (Closed) - MonTask: line 6556 in file ../../bbu/onfiBBM.c is seen when you delete NVRAM SCGCQ00678566 - (Closed) - Automatically VD gets created for mirror arm of 1st VD on joining the mirror arm of 2nd VD as new virtual drive. SCGCQ00665475 - (Closed) - To properly handle the OCR case with RESET Status Register. SCGCQ00574358 - (Closed) - Allow UEFI and BIOS to be Enabled/Disabled individually SCGCQ00523879 - (Closed) - Identify physical location of a target device SCGCQ00566306 - (Closed) - Add type BIOS for HashImageType. SCGCQ00569175 - (Closed) - Add product-specific Flag bit to Clean Tool SCGCQ00621554 - (Closed) - Refactor Buffer Manager to avoid overheads with various lists SCGCQ00648403 - (Closed) - Roll back latency improvements from MR6.4 SCGCQ00660441 - (Closed) - Short term fix for PPC476 Errata SCGCQ00674506 - (Closed) - Long term work around for PPC 476 Errata #46 SCGCQ00692938 - (Closed) - Remove unwanted prints in sysDMA path SCGCQ00602088 - (Closed) - Command timeouts with cdb=ff ff ff ff SCGCQ00669013 - (Closed) - Disable cache bypass in least latency mode SCGCQ00674233 - (Closed) - F/w changes to set deviceExposure default from NVDATA SCGCQ00524743 - (Opened) - Enable support L3 auto-flush on power fail when BBU is connected SCGCQ00586309 - (Closed) - Enable cache bypass for better performance with large writes on WB volumes SCGCQ00599993 - (Closed) - Remove EBBU code as it is no longer needed SCGCQ00634750 - (Closed) - Requirement for 512e implementation changes SCGCQ00654566 - (Closed) - Work Around for PPC 476 Errata #46 in MR Firmware SCGCQ00626667 - (Closed) - Add Mirror Join functionality SCGCQ00654568 - (Closed) - Work Around for PPC476 Errata #46 in iMR Firmware SCGCQ00599829 - (Closed) - Refactor DM for modularity SCGCQ00634792 - (Closed) - Need to support both SAS and SATA disks in the same dual path/expander jbod/backplane SCGCQ00642323 - (Closed) - Driver support for read IO load balance on more a >2 drive R1 volume SCGCQ00589296 - (Closed) - Misc code cleanup for performance improvement SCGCQ00556387 - (Port_Complete) - VPD (Vital Product Data) needs to identify PCB hardware level SCGCQ00564594 - (Port_Complete) - Output async event message to upper layer when it detected "Write Timeout" in between on-board flash SCGCQ00574402 - (Port_Complete) - Display the NCQ enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI SCGCQ00605439 - (Port_Complete) - FW debugger scrolls continuous message and eventually resets after deleting Source VD during a Cachecade disassocation SCGCQ00609779 - (Port_Complete) - Add Fastpath Support by Default for a particular OEM. SCGCQ00619496 - (Port_Complete) - Storecli reporting incorrect values for tfm and supercap date of manufacture SCGCQ00630129 - (Port_Complete) - Bad battery warning message that comes up during POST isn't aligned properly. SCGCQ00630133 - (Port_Complete) - Static analysis tool defects SCGCQ00642804 - (Port_Complete) - Wrong behavior of Break Mirror operation on starts rebuild SCGCQ00643486 - (Port_Not_Required) - Getting Question Value mismatch when entering Controller management screen SCGCQ00651193 - (Port_Not_Required) - Battery learn cycle continues to more than one cycle even FW has marked it as bad in previous reboot SCGCQ00651381 - (Port_Not_Required) - DC observed upon performing OCR on a degraded R1 (AWB). SCGCQ00656141 - (Port_Complete) - CacheCade data loss after reboot SCGCQ00662365 - (Port_Complete) - Write buffer flash programming support SCGCQ00663056 - (Port_Complete) - CC doesn't correct medium error in P drive SCGCQ00666941 - (Port_Complete) - Start a learn even if the SuperCap is not completely charged. SCGCQ00666982 - (Port_Complete) - Change the cache policy of Virtual Drives(VDs) to Write Through(WT) if SuperCap temperature goes above 60 degree Celsius. SCGCQ00667965 - (Port_Complete) - CS2.0: Coverity defects (11619, 14267, 14334) SCGCQ00675271 - (Port_Complete) - Updated long term WA for PPC errata #46 SCGCQ00675820 - (Port_Complete) - Updated long term WA for PPC errata #46 SCGCQ00678184 - (Port_Complete) - MonTask: line 4699 in file ../../raid/ld.c seen on iMR FW during boot to OS with R0 and PRL11 VD SCGCQ00681040 - (Port_Complete) - PD is reported as a 'HSP by storcl64 which is neither DHSP nor GHSP. SCGCQ00682665 - (Port_Complete) - Cache offload failure with pinned cache on R5 VD SCGCQ00690088 - (Port_Complete) - DIS mismatch while running system reboot script with dirty data in DDR SCGCQ00692999 - (Port_Complete) - Data Corruption is taking place on Windows OS installed on top of ESX 5.5 U1 OS. SCGCQ00695994 - (Port_Complete) - Serial prints getting jumbled up due to print message inside spourious interrupt handler. SCGCQ00706936 - (Port_Complete) - Cache offload not triggered on few servers rarely SCGCQ00714274 - (Port_Complete) - Serial prints getting jumbled up due to print message inside spourious interrupt handler. SCGCQ00614988 - (Port_Not_Required) - not enough bs found during double Dip power cycle Test SCGCQ00630137 - (Port_Complete) - Unable to suspend the Patrol Read operation in iMR mode from the HII application SCGCQ00639588 - (Port_Complete) - Hitting montask line 1930 in file ../../bbu/onfi.c while running FP IO's on degraded VD's SCGCQ00642810 - (Port_Complete) - Copyback is not start immediately after reconstruction is completed in OS. SCGCQ00642816 - (Port_Complete) - Send Inquiry after expander responds with Unit Attention Microcode Change SCGCQ00650280 - (Port_Complete) - FW Breaks while importing Foreign Config(BS Assertion Failure while flushing the pinned cache) SCGCQ00654731 - (Port_Not_Required) - Fw hit montask with machinecheck exception on PD pushpull with IO on R5 SCGCQ00662326 - (Port_Complete) - Prevent data correction in pagefil.sys to happen during Check Consistency after heavy I/O test. SCGCQ00662532 - (Port_Complete) - locate behavior will incorrect light some drive LED not located after some loop locate test on 3108 MR+PMC Expander SCGCQ00663057 - (Port_Complete) - Check and resume rebuild after a stipulated time SCGCQ00671448 - (Port_Complete) - To properly handle the OCR case with RESET Status Register. SCGCQ00676945 - (Port_Complete) - For OEM do cache offload for when cache is is dirty (WB and ForceWB modes) and when there is a battery present (WT mode). SCGCQ00676950 - (Port_Complete) - DHS that becomes GHS does not start rebuilding automatically with an already degraded VD SCGCQ00679174 - (Port_Complete) - MonTask: line 4699 in file ../../raid/ld.c seen on iMR FW during boot to OS with R0 and PRL11 VD SCGCQ00682959 - (Port_Complete) - Enter Montask during rebuild after reboot SCGCQ00714465 - (Port_Complete) - When we attempt to retrieve iMR Thunderbolt controller firmware logs using an application, we see some lines that are wrapped without starting on a new line. SCGCQ00601065 - (Port_Not_Required) - Getting Question Value mismatch when entering Controller management screen SCGCQ00619497 - (Port_Complete) - Pinned cache gets flushed to incorrect VD for mirrored RAID levels SCGCQ00625016 - (Port_Complete) - montask seen with "Assertion failure in line 4168" on running IO on 4K VD. SCGCQ00628213 - (Port_Complete) - correct when copyback (replace) for R11 can be done. SCGCQ00630147 - (Port_Complete) - Unable to discard pinned cache in Headless Safe Mode. SCGCQ00650926 - (Port_Complete) - JetStress average database write latency is above previous generation controller SCGCQ00651383 - (Port_Not_Required) - Hitting montask line 1930 in file ../../bbu/onfi.c while running FP IO's on degraded VD's SCGCQ00662330 - (Port_Complete) - (SATA) Failed temperature Capture on when link up/down experienced SCGCQ00665693 - (Port_Complete) - TFM/BBU error seen with latest TFM FW/VPD SCGCQ00669083 - (Port_Complete) - Cannot import foreign configuration. SCGCQ00674858 - (Port_Complete) - Updated long term WA for PPC errata #46 SCGCQ00677304 - (Port_Complete) - Estimated Time Left" shows confusing values SCGCQ00679755 - (Port_Complete) - Cell Disk With Status not Present Was Found to be Showing a Green Status Light SCGCQ00679766 - (Port_Complete) - MonTask: line 4699 in file ../../raid/ld.c seen on iMR FW during boot to OS with R0 and PRL11 VD SCGCQ00696015 - (Port_Complete) - Data Corruption is taking place on Windows OS installed on top of ESX 5.5 U1 OS. SCGCQ00623210 - (Port_Complete) - expander not spinning up all disks (1.8 SSDs) SCGCQ00625642 - (Port_Complete) - Fault LED is not set when drive is bad SCGCQ00668344 - (Port_Complete) - Coverity defects (11619, 14267, 14334) SCGCQ00669082 - (Port_Complete) - Limit the number of retries when learn fails to start after firmware issues the learn command. SCGCQ00601559 - (Port_Complete) - Write buffer flash programming support SCGCQ00620171 - (Port_Complete) - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset SCGCQ00664887 - (Port_Complete) - converting MR to IMR fails SCGCQ00670778 - (Port_Complete) - SecureVD erase is not resumed on reboot in ronaldo server. SCGCQ00673077 - (Port_Complete) - Data corruption after media error correction SCGCQ00570181 - (Port_Complete) - Deep learn will not start immediately when Relative State of Charge (RSOC) of battery is equal to 95%. SCGCQ00666938 - (Port_Complete) - If cache offload happens during a relearn, then the Firmware will halt at next boot for the learn completion. SCGCQ00676948 - (Port_Complete) - I2C Issue - Unintended failures following response timeout SCGCQ00646713 - (Port_Complete) - Cannot recover data from a recoverable media error after Patrol Read encounters recovery failure for RAID-1 SCGCQ00651316 - (Port_Complete) - Change when checking if copyback can be done on a PD in a PRL11 ROMENV 1.09 BootBlock 3.02.00.00-0001 NVDATA 3.1406.00-0075 Numerous changes for specific customers UEFI_Driver 0x06080500 (SIGNED) SCGCQ00638308 - (Closed) - FMP GetImageInfo could result in stack corruption - Code Review Defect ID D26304 SCGCQ00628627 - (Closed) - UEFI Driver- has debug print statements during POST SCGCQ00628310 - (Closed) - Install FMP on Controller Handle at Start() and the exception SCGCQ00550389 - (Closed) - Write Caching HBA, JBOD/R0 supported TB controller with 240 SystemPD/LD support SCGCQ00626601 - (Implemented) - VT-d/IOMMU support for iMR - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00635878 - (Port_Complete) - UEFI Driver- has debug print statements during POST SCGCQ00677776 - (Port_Complete) - Initilize the buffer that we allocate to load HII and return EFI_OUT_OF_RESOURCES if allocation fails SCGCQ00678154 - (Port_Not_Required) - For OEM dont free the host memory during disconnect/unload process SCGCQ00679073 - (Port_Complete) - Do not go to WebBIOS due to a bad health status when WebBIOS is disabled in NVDATA. SCGCQ00644508 - (Port_Complete) - CPU EXCEPTION ERROR (Dont double free the memory) SCGCQ00644509 - (Port_Complete) - CPU EXCEPTION ERROR (Dont double free the memory) SCGCQ00644856 - (Port_Complete) - Install FMP on Controller Handle at Start() and the exception SCGCQ00661595 - (Port_Complete) - Timeout is not passed correctly to FW SCGCQ00644859 - (Port_Complete) - FMP GetImageInfo could result in stack corruption - Code Review Defect ID D26304 SCGCQ00658168 - (Port_Complete) - ATA Pass thru: Timeout is not passed correctly to FW Hii v03.09.06.00 (SIGNED) SCGCQ00625438 - (Closed) - Minor Typos and consistency issues in HEFU HII help text SCGCQ00633320 - (Closed) - Handling code collaborator Defects: SCGCQ00573222 and SCGCQ00568814 SCGCQ00602492 - (Closed) - HII fails to list the foreign configuration SCGCQ00658674 - (Closed) - Hii - Restrict the user from creating the 65th VD. SCGCQ00630532 - (Closed) - Consistency Check Start - remove mm/dd/yyyy from the string as the format is out of control of LSI SCGCQ00624890 - (Closed) - Handling Code Collaborator Defect: SCGCQ00573222 SCGCQ00678695 - (Closed) - Change the Step Value to 0 for all numeric to make sure for free edit instead of Incrementing and decrementing using +/- SCGCQ00640534 - (Closed) - HII is showing RAID6 and RAID5 levels while creating VD when we have 2 512n drives and 1 4k Drives SCGCQ00645532 - (Closed) - Update the string for " SCGCQ00679861 - (Closed) - Not able to create VD with 4k drives SCGCQ00637539 - (Closed) - Remove FMP installed on the controller handle in HII SCGCQ00678603 - (Closed) - HII does not display power state of a PD SCGCQ00627778 - (Closed) - Address review comments SCGCQ00672925 - (Closed) - Unable to set spinup drive count in HII SCGCQ00550390 - (Closed) - Write Caching HBA, JBOD/R0 supported TB controller with 240 SystemPD/LD support SCGCQ00626605 - (Closed) - Clone SCGCQ00556243 HII-based PCI Inventory - MR) into the mainline SCGCQ00620259 - (Closed) - Port 240VD change to Tbolt SCGCQ00441334 SCGCQ00634019 - (Closed) - Change the default Setting of Disk Cahce Policy from Unchanged to Disable. SCGCQ00626591 - (Closed) - Add Mirror Join functionality - PR SCGCQ00521537 SCGCQ00626585 - (Closed) - Requirement for 512e implementation changes - PR SCGCQ00425778 SCGCQ00642232 - (Closed) - Ability to enable/disable JBOD mode in HII SCGCQ00621285 - (Closed) - Change the wording in HII from Check Consistency to Make data consistent SCGCQ00652171 - (Port_Complete) - HII is gave a option to start reconstruction from any degraded RAID level to RAID 0. SCGCQ00677103 - (Port_Complete) - Detail Drives info shows incorrectly in BIOS - unknown characters appearing SCGCQ00679042 - (Port_Complete) - Enhance strings for Locked foreign config import feature SCGCQ00644857 - (Port_Complete) - Remove FMP installed on the controller handle in HII SCGCQ00644858 - (Port_Complete) - RSOD during POST after enabling SecureBoot - HEFU.ROM should report exact size of .EFI image SCGCQ00661685 - (Port_Complete) - HII reports wrong data under 'Eligible JBOD Drives for conversion' while converting JBOD to UG SCGCQ00652168 - (Port_Complete) - In HII ,Full initialization is not grayed out for R6 DIF arrays. SCGCQ00603251 - (Port_Complete) - Creation+ FW updation+ Scan foreign Configuration is disabled/grayed out in HII page SCGCQ00652424 - (Port_Complete) - change the numeric primitive's maximum from MAX_PHYSICAL_DRIVES to 0xff SCGCQ00644788 - (Port_Complete) - Enhance help message for PD/VD Operation field SCGCQ00679036 - (Port_Complete) - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties SCGCQ00634684 - (Port_Complete) - RSOD during POST after enabling SecureBoot - HEFU.ROM should report exact size of .EFI image SCGCQ00644575 - (Port_Complete) - Consistency Check Start - remove mm/dd/yyyy from the string as the format is out of control of LSI SCGCQ00652169 - (Port_Complete) - HII reports wrong data under 'Eligible JBOD Drives for conversion' while converting JBOD to UG SCGCQ00652170 - (Port_Complete) - HII is showing RAID levels, irrespective of drives to configure a new RAID level. SCGCQ00679049 - (Port_Complete) - "Make Unconfigured good" option missing in HII even if JBOD's are present in the config SCGCQ00682962 - (Port_Complete) - creation in HII is showing GB SCGCQ00644786 - (Port_Complete) - Enhance help message for PD/VD Operation field SCGCQ00682960 - (Port_Complete) - HII is not displaying the cachecade 512GB warning message FCODE 4.16.08.00 BIOS 6.19.05.0 SCGCQ00626821 - (Closed) - 240VD Support: In Post Restrict to 64 VD only SCGCQ00629987 - (Closed) - With more than 64 VD's in the configuration, number of Virtual Drives handled by BIOS message is not shown in the POST. SCGCQ00659974 - (Closed) - OpROM - If there is boot message, BIOS won't detect > 64 VDs SCGCQ00653048 - (Closed) - AutoSelectBootLd is not working if user has OS in VD > 64 SCGCQ00632011 - (Closed) - Firmware enters faults state after a reboot on flashing firmware with IO in progress. SCGCQ00682646 - (Closed) - Display the first 64 VDs in the POST (in the same sequence we get it from FW) SCGCQ00626602 - (Implemented) - VT-d/IOMMU support for iMR - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00621895 - (Closed) - WebBIOS of MR card hangs due to bios control mis-direct SCGCQ00550388 - (Closed) - Write Caching HBA, JBOD/R0 supported TB controller with 240 SystemPD/LD support SCGCQ00679070 - (Port_Complete) - Display Warning Message when Preboot Configuration Utility are Disabled and User tries to lunch it Ctrl-R 5.06-0003 SCGCQ00647392 (DFCT) - join mirror-mirror drive is not seen in join mirror-choose option in CTRL-R SCGCQ00648182 (DFCT) - Port informations are not displayed in Connector field for the drives attached to antares card. SCGCQ00663996 (DFCT) - Not able to change emulation properties in CTRL-R for iMR SCGCQ00666806 (DFCT) - Set factory defaults option is blocking the "prev" button in controller properties page SCGCQ00666807 (DFCT) - "enable jbod" help file is not opening with f1 option on it. SCGCQ00667550 (DFCT) - Not able to Manually stop or suspend the copyback operation once started SCGCQ00677458 (DFCT) - Under Join mirror-choose option page existing drives for second R1 VD are not listed. SCGCQ00677460 (DFCT) - Montask on joining the mirror arm as new virtual drive when doing with the second array. SCGCQ00678600 (DFCT) - Gramatical Error in Ctrl-R while modifying SuperCap properties SCGCQ00625148 (DFCT) - in-appropriate drive state is seen on connecting back the drives in ctrl-r . SCGCQ00625164 (DFCT) - not able to navigate in the warning message window for having more than 64VD. SCGCQ00625175 (DFCT) - on having more than 64 VD's and initiating a copyback from ctrl-r will result in montask SCGCQ00628684 (DFCT) - OEM enclosure connected in multi-path is not showing all ports SCGCQ00642546 (DFCT) - Help is missing for break and join mirror feature in Control-H SCGCQ00644056 (DFCT) - Join mirror is not enabled in CTRL-R SCGCQ00646220 (DFCT) - Getting an option in join mirror to select both "add new vd" and "existing VD" in ctrl-r SCGCQ00647015 (DFCT) - LD emulation properties not getting set on updating VD properties SCGCQ00606059 (DFCT) - Ctrl-R - In iMR controller we are able to set VD properties to write back and cached . SCGCQ00614734 (DFCT) - unable to cretae VD with property "Write back with BBU" SCGCQ00615350 (DFCT) - In multicontroller environment unable to enter in to ctrl-R after 1st controller initililization. SCGCQ00635638 (DFCT) - spelling issue in help file of VD Size. SCGCQ00630099 (ENHREQ) - Requirement for 512e implementation changes SCGCQ00632051 (ENHREQ) - Added the OEM check for getting default disk-cache policy in Libmods as Disable. SCGCQ00634020 (ENHREQ) - Added the OEM check for getting default disk-cache policy in Libmods as Disable. PCLI 1.07.05 Package: 24.3.0-0071 (MR6.3 point release) iMR Firmware - 4.230.31-3804 SCGCQ00756731 - Need MR 6.3 iMR Firmware Capable of Updating the SBR on a Customer Board in the Field Package: 24.3.0-0065 (MR6.3 point release) iMR NVDATA - 3.1403.01-0063 SCGCQ00759962 - Customer NVDATA changes for PHY-to-SLOT mapping Package: 24.3.0-0062 (MR6.3 point release) Firmware - 4.230.31-3729 SCGCQ00755473 - Truchas Valley reporting temperature differential error Package: 24.3.0-0054 (MR6.3 patch) Firmware - 4.230.31-3587 SCGCQ00625524 - When we attempt to retrieve iMR Thunderbolt controller firmware logs using an application, we see some lines that are wrapped without starting on a new line. SCGCQ00695317 - Serial prints getting jumbled up due to print message inside spourious interrupt handler. SCGCQ00675262 - Data Corruption is taking place on Windows OS installed on top of ESX 5.5 U1 OS. SCGCQ00665475 - ONFI: To properly handle the OCR case with RESET Status Register. SCGCQ00677803 - Cache offload failure with pinned cache on R5 VD SCGCQ00674392 - Updated long term WA for PPC errata #46 SCGCQ00568080 - Defect Fix for VPD and inquiry callback issues in DISM SCGCQ00568134 - Patrol read will not start on any VD after a PR is started, suspended and VD is deleted SCGCQ00569895 - Defect Fix for Command gets retried infinitely times when drive responds with 0B/47/03 always SCGCQ00572662 - FW failure during read on 3PD R5 with 1000 CME with skip count 2 SCGCQ00574276 - FW breaks if wrong security key is entered SCGCQ00580162 - Only 1mb crash dump is getting generated of fw fault SCGCQ00580847 - not enough bs found during double Dip power cycle Test SCGCQ00586163 - cache restore failure message displayed though cache restore was successfull SCGCQ00588173 - Routines to inject bit error in NF and ecc error in DDR for ONFI SCGCQ00588185 - Mismatch in LD id and target ID during set/reset boot device SCGCQ00589365 - on breaking the multipath in loop while drives are spinnning up will result in montask SCGCQ00589728 - FW hangs while creating 64 VDs on the controller with SLES11 SP2 SCGCQ00592996 - While running reconstruction from R1 to 4 drive PRL11 with IO,FW hits to MonTask: line 1270 in file ../../raid/1078dm SCGCQ00593776 - SMART poll needs to issue log sense with page control set to current/ cummulative value SCGCQ00602556 - Static analysis tool defects SCGCQ00602665 - Static analysis tool defect SCGCQ00602726 - Static Analysis Tool defects SCGCQ00602855 - Static analysis tool defect SCGCQ00603306 - static analysis tool defects resolution SCGCQ00603564 - added support for debugqueue SCGCQ00603779 - Not getting "Clear ldbbm badblocks" options on VD SCGCQ00611275 - FW goes to kill adaptor to handle partial copy of crash_dump SCGCQ00612927 - Montask in divert.c seen when injecting 64K consecutive errors on R0 VD, Patrol Read running in background. SCGCQ00614455 - Static analysis tool defects SCGCQ00625843 - PR Progress event is not generated for 1TB/3TB SATA drive SCGCQ00634578 - Defect fix for kenel panic with iMR Fury with Free BSD driver SCGCQ00636748 - Running Storcli /C0/CV show or (show all) starts a relearn on supercap issue SCGCQ00451219 - Defect Fix for Online DIF drives are getting punctured after PI enabled R5 VDs are offlined with pinned cache SCGCQ00574071 - md5sum mismatch seen on a copied file from R5 VD with CME SCGCQ00574277 - Power removal of enclosure FW hits to MonTask: line 4056 in file ../../bbu/onfiBBM.c SCGCQ00586190 - Fix GNU make file compilation SCGCQ00586341 - Crash Dump Error Handling SCGCQ00605227 - When OS on VD ,after collecting crash dump file system becomes readable SCGCQ00606571 - Physical drives go to power save mode just after restarting the server SCGCQ00610881 - storcli and CtrlR still show new PD information as 4K sector after replacing a 4K sector drive with a 512 sector drive SCGCQ00630075 - Unexpected power state change SCGCQ00631492 - Media error on Last sector of stripe isn't added to LDBBM list SCGCQ00524842 - CME logic using overlaid fields in c->rec SCGCQ00568655 - defect fix for Compilation issue SCGCQ00575006 - Too many unexpected sense AEN raised by CC during CME recovery on R5 SCGCQ00593295 - Not able import foreign configuration immediately after breaking the mirror. SCGCQ00602561 - Static Analysis Tool defects SCGCQ00563498 - FW should not try to boot iMR mode without informing host if ECC error happens when OS is running. SCGCQ00577680 - spin up tracker dequeue is not handled for case in which TUR error happens even after MAX retries SCGCQ00603086 - Kill adapter is seen while performing CME recovery during Write operation. SCGCQ00466289 - PDs more than 32 which has configuration, is reporting as JBODs after importing from MR to IMR SCGCQ00546691 - hostCmdSortingWrites is not updated when VD policy changes(WT/WB) SCGCQ00576138 - The restore successful and unsuccessful prints to be handled properly SCGCQ00560474 - code review change implemented SCGCQ00531118 - Changes to support PD IO history SCGCQ00564339 - Enable break mirror support SCGCQ00574801 - Implemented Fix to Problem [PDs more than 32 which has configuration, is reporting as JBODs after importing from MR to IMR] SCGCQ00577793 - Moved divert code from iopath region to save memory SCGCQ00621767 - Update Ptolemy VPD and GasGauge with COL settings for a OEM SCGCQ00624326 - Disable sgpioSmpPresenceDetect for OEM SCGCQ00625006 - Show valid ROC temperatuer SCGCQ00625044 - Change SES Green/Amber LED behavior SCGCQ00567706 - Extened LDBBM table to hold more bad block entires ( SCGCQ00295621); with relevent increase in divert nodes. SCGCQ00588208 - Adding test routine for the bad block loop test for PR SCGCQ00423195 SCGCQ00563795 - Modify MR fw to eliminate four second window where drive swap is not recognized. SCGCQ00564166 - Single image support for ONFI SCGCQ00455360 - Implement CME solution for "Do not allow 3 minute timer to expire forceing driver to kill fw on CME/disk timeout/etc. SCGCQ00563486 - Make MR to iMR migration generic on TMM fault SCGCQ00562733 - Support for DIS feature in dual image SCGCQ00530866 - command storclif /c1 start diag duration=0 causes controller card to montask. SCGCQ00564367 - BGI operation still running on RAID0 VD even after PI protection disabled SCGCQ00566951 - LED Blink operation doesn't stop after VD deletion SCGCQ00579929 - SGPIO functionality is not working when only cable A is connected SCGCQ00579931 - Potential null pointer derefence SCGCQ00614997 - Physical drives go to power save mode just after restarting the server SCGCQ00614998 - Physical drives go to power save mode just after restarting the server SCGCQ00615001 - Montask in divert.c seen when injecting 64K consecutive errors on R0 VD, Patrol Read running in background. SCGCQ00617621 - cache restore failure message displayed though cache restore was successfull SCGCQ00620166 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset SCGCQ00620168 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset SCGCQ00620169 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset SCGCQ00621785 - CME handling of Invader SCGCQ00622709 - storcli and CtrlR still show new PD information as 4K sector after replacing a 4K sector drive with a 512 sector drive SCGCQ00624531 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap. SCGCQ00631230 - SSD causes system to hang at POST SCGCQ00631232 - Behavior change when FW hit fault code 0x81 (uncorrectable ECC error) SCGCQ00631474 - Power removal of enclosure FW hits to MonTask: line 4056 in file ../../bbu/onfiBBM.c SCGCQ00631478 - Adding 2GB DDR and 4GB Flash combination support for Single Image Write. SCGCQ00637535 - FW hits MonTask: line 1143 in file ../../raid/pd.c on starting VD erase in standard mode. SCGCQ00638312 - FW crash while launching Ctrl+R SCGCQ00640126 - 9240-4i is not getting required memory resources on boot, on Linux it waits 5 minutes, resets the SCGCQ00640469 - Running Storcli /C0/CV show or (show all) starts a relearn on supercap issue SCGCQ00640470 - L2/L3 cache error on H330 MM & H330 MB on reboot SCGCQ00643455 - Defect fix for kenel panic with iMR Fury with Free BSD driver SCGCQ00643524 - Defect fix for kenel panic with iMR Fury with Free BSD driver SCGCQ00643526 - 9240-4i is not getting required memory resources on boot, on Linux it waits 5 minutes, resets the SCGCQ00658583 - Work Around for PPC 476 Errata #46 in MR Firmware SCGCQ00658585 - Work Around for PPC476 Errata #46 in iMR Firmware SCGCQ00495877 - disableBatteryWarning should not be reset if changed by user SCGCQ00552416 - firmware 25.2.0-0013 causes the SEP to not be seen on x4 Equinox SCGCQ00555332 - Transparent Learn Cycle does not kick off and RSOC (Relative State Of Charge) eventually goes down to 0%. SCGCQ00559322 - EEprom CRC error is detected when WebBIOS is running SCGCQ00579928 - AdpDiags does not fail when the SAS link is down SCGCQ00588880 - HDD resume failed during dimmer switch test method. SCGCQ00630382 - Add MaintainPdFailHistory clear function SCGCQ00631340 - Single image support for ONFI SCGCQ00637536 - FW hits MonTask: line 1143 in file ../../raid/pd.c on starting VD erase in standard mode. SCGCQ00675820 - Updated long term WA for PPC errata #46 SCGCQ00504394 - For a particular OEM, size of some 4TB drives is reported as zero SCGCQ00523966 - Rebuild failed event is not seen when rebuild fails due to LDBBM and SBBM tables getting full (puncturing disabled) SCGCQ00552446 - Implement I2C Slave Address for Sideband Management SCGCQ00563282 - OEM hi-temp warning not being displayed SCGCQ00570249 - OEM SGPIO support not working SCGCQ00574969 - Retention test failure during stress test SCGCQ00596686 - cntr-R fails to show correct PD sector size once PD's swapped to same slot 512B PD with 512e PD type SCGCQ00621783 - Assertion failure (not enough BS found) in double DIP power cycle test case SCGCQ00646386 - DIS mismatch while running system reboot script with dirty data in DDR SCGCQ00366011 - FW goes to montask at cache offload. SCGCQ00498741 - Megamon during Injecting errors to VD with 512e PDs on iMR controller SCGCQ00526627 - Faulty protocol used for changing the Disk Write Cache Policy SCGCQ00530868 - "OOB:Got DCMD, but FW is not ready " meesages are flooding in tty log during OCR . SCGCQ00553197 - Prevent overtemp warnings while charging between 45C and 50C SCGCQ00560388 - adapterOperations.alarmControl is being set to 1 even if controller doesnot have alarm on board SCGCQ00567378 - CLI Reporting of TMM VPD SCGCQ00556598 - megacli reports battery pack is missing on hot insertion SCGCQ00679766 - MonTask: line 4699 in file ../../raid/ld.c seen on iMR FW during boot to OS with R0 and PRL11 VD SCGCQ00550612 - Do not print VPD86 errors for BP/expander SCGCQ00552415 - Modify WCE bit for improved Linux performance SCGCQ00560393 - When attempting to secure LD during RLM, receive option to secure LD, LD not secured (message incorrect/misleading.) SCGCQ00558037 - Megamon issue when disabling the drive security on a MR controller with spun down FDE drives. SCGCQ00560476 - Unable to open "Set Patrol Read Properties" in MSM with 2008-iMR BIOS - 6.17.04.0 SCGCQ00579962 - Initialize deviceExposure with MAX_INT13DISKS instead of 0xFF SCGCQ00572939 - Make sure all the make file adheres to the latest binary names. SCGCQ00559095 - Provide an option to limit the max number of INT 13h devices presented to system BIOS UEFI_Driver - 0x06060A01 (Signed) SCGCQ00618669 - StartHiiBackEnd() has Print statement with %g SCGCQ00578194 - UEFI Driver should calculate checksum before setting bios data (MR_BIOS_DATA) SCGCQ00601851 - System hang when we press F1 on second time when we are in HII form SCGCQ00628627 - UEFI Driver- has debug print statements during POST SCGCQ00589148 - Diskpart EFI utility can't create partition on a JBOD SCGCQ00526851 - Support EFI_FIRMWARE_MANAGEMENT_PROTOCOL for controller firmware upgrade. SCGCQ00579837 - UEFI Driver should calculate checksum before setting bios data (MR_BIOS_DATA) SCGCQ00606367 - UEFI Driver returns EFI_NOT_FOUND when platform passes valid Target for ExtSPT.BuildDevicePath() SCGCQ00644856 - Install FMP on Controller Handle at Start() and the exception SCGCQ00644859 - FMP GetImageInfo could result in stack corruption - Code Review Defect ID D26304 SCGCQ00580313 - User can't access RAID HII in UEFI mode after removing a HDD Hii - 03.07.12.01 (Signed) SCGCQ00579816 - HII\EKM-LKM without reboot should show proper message SCGCQ00594011 - With out selecting any drives I am seeing the previous config VD size. SCGCQ00609737 - Confiuration Restore is not working SCGCQ00618674 - StartHiiImpl() WriteToLogger uses %g and EFIHiiDriverEntryPoint() Print statement uses %g for displaying EFI status SCGCQ00521488 - Getting error message when we suspend Patrol read operation through HII browser SCGCQ00565876 - Remove duplicated strings from the UNI FIle SCGCQ00571353 - Allow user to select RAID level when controller has other VD + error handling SCGCQ00573871 - fixing code review defects (AIM version + UCM GUID + deallocation) SCGCQ00614027 - Firmware updation fails in OEM machine SCGCQ00615221 - Form UF003 prints error messages (use WriteToLogger to log these debug messages) SCGCQ00617617 - FWMgmt Prtocol: has no "versionid" info. SCGCQ00565088 - Help content for Firmware Update in Controller Management is inappropriate SCGCQ00569098 - Enter security key for locked drives screen, press down to get to OK, OK will show up again on right SCGCQ00598822 - VD details display is improper in Expand Virtual Drive SCGCQ00613822 - Advanced Controller Properties- Power Saving Settings has broken form SCGCQ00556839 - Able to select EKM even when the EKM FOD key is removed from the system. SCGCQ00589301 - System/HII hang when clicks on Hardware Components menu option in HII. SCGCQ00595864 - On Success of creating Drive Security Form loads into Advacned controller properties SCGCQ00598431 - IMR Liberator Drop Down option in VD properties for Cached is present SCGCQ00610889 - Customize help string for Select Interface Type SCGCQ00615190 - Fill Controller Index in RouteConfig + for UF003 calculate checksume only for the actual config size SCGCQ00593558 - Auto Learn Mode is showing wrong data SCGCQ00612574 - Addressed review comments SCGCQ00613820 - Typo in HII form Controller Status SCGCQ00622464 - Toggling bewtween Legacy to Uefi mode vice versa junk values seen . SCGCQ00524969 - HII PKG 0006/Going from LKM to EKM asks for a Current Security key Identifier and Security key. SCGCQ00590465 - On selecting a wrong parameter for size while creating VDs, Options greyed, Create VD page exits to parent page. SCGCQ00595463 - Security feature is enabled but HII sees "Drive Security" as disabled SCGCQ00571359 - UCM Phase 1: Typo "Clear Configuaration" -> "Clear Configuration" SCGCQ00573222 - Handling Code Collaborator Review Defects for SCGCQ00568814 and SCGCQ00569197 SCGCQ00575062 - added a while loop and take care of the multiple PD Groups scenario. SCGCQ00578190 - HII should calculate checksum before setting bios data (MR_BIOS_DATA) SCGCQ00597641 - MR6.3 HII aesthetic change SCGCQ00503036 - Changing Percentage of Space to Expand Does not Update Final VD Size SCGCQ00574041 - AIM (Agentless Inventory Manager) Issues SCGCQ00574989 - Creation+ FW updation+ Scan foreign Configuration is disabled/grayed out in HII page SCGCQ00614466 - HII 03.07.05.00/Under advanced controller properties and selecting Cache and Memory, it says's "scontroller cache" SCGCQ00614675 - To address FW Update help Strings SCGCQ00619028 - Not able to schedule CC in concurrent mode from HII(03.07.09.00). SCGCQ00526978 - HII. Provide controller FW update function SCGCQ00568814 - HEFU. Simplify controller propety page SCGCQ00568706 - Remove limitation for creating R6 in HII for OEM SCGCQ00612466 - Provide pop-up to display current version and update fw version as part of HEFU HII Firmware Update functionality SCGCQ00571579 - (Implemented) - Create a formset with classGUID that customer has provided. SCGCQ00569197 - Move Disable Protection option from Controller Management to VD management SCGCQ00557522 - System hang observed when the "PdInfo.userDataBlockSize" is set to 0 SCGCQ00601110 - Able to select EKM even when the EKM FOD key is removed from the system. SCGCQ00601103 - Enter security key for locked drives screen, press down to get to OK, OK will show up again on right SCGCQ00601107 - HII PKG 0006/Going from LKM to EKM asks for a Current Security key Identifier and Security key. SCGCQ00601119 - HII help for Boot error handling does not display "Stop On Error" option SCGCQ00644857 - Remove FMP installed on the controller handle in HII SCGCQ00644858 - RSOD during POST after enabling SecureBoot - HEFU.ROM should report exact size of .EFI image SCGCQ00629813 - RSOD during POST after enabling SecureBoot - HEFU.ROM should report exact size of .EFI image SCGCQ00601113 - HII\EKM-LKM without reboot should show proper message SCGCQ00601117 - UCM Phase 1: Allow user to select RAID level when controller has other VD + error handling SCGCQ00572986 - System hang observed when the "PdInfo.userDataBlockSize" is set to 0 SCGCQ00644575 - Consistency Check Start - remove mm/dd/yyyy from the string as the format is out of control of LSI SCGCQ00596920 - Missing BBU caused disappearance of Enclosure Mgmt opt in BIOS setup SCGCQ00603235 - HII help window shows unsupported stripe sizes SCGCQ00601116 - added a while loop and take care of the multiple PD Groups scenario. SCGCQ00601118 - UCM Phase 1: Typo "Clear Configuaration" -> "Clear Configuration" SCGCQ00601120 - In HII on a ready drive we are able to see Used space as 40Gb. SCGCQ00644786 - Enhance help message for PD/VD Operation field FCODE - 4.16.08.00 SCGCQ00553069 - PCLI(1.07.05) Sparc: Command "cli set securitykey=Lsi@12345" fails with errcd "1001" and errmsg "invalid key". IMR NVDATA - 3.1403.01-0061 SCGCQ00709554 - Revise Drive Spin-Up Timing on OEM 12G iMR and MR Boards SCGCQ00685089 - Addition of ManPage1 values to the xml file. SCGCQ00696438 - Customer NVDATA Change request for iMR SCGCQ00692947 - Dual write NVDATA changes for customer SCGCQ00673357 - Flatwoods Showing Same Slot Number for All Drives SCGCQ00658482 - breakMirrorRAIDSupport for single span Raid 1 BootBlock - 3.02.00.00-0001 SCGCQ00685115 - Memory/battery problems in Focused Regression SCGCQ00505902 - Coherency bit is disabled in SRAM TLBs Ctrl-R - 5.04-0002 SCGCQ00644489 - Added a new Control to enable/disable JBOD on the controller in Ctrl Mgmt page. SCGCQ00648965 - Display the Battery status as N/A for iMR cards. SCGCQ00584991 - current write policy is not getting updated untill we press f5 SCGCQ00584993 - unable to diplay the reason for difference in write policy SCGCQ00593822 - Both the Connector information(0-3 & 4-7) is not shown in PD properties while connected in Multipath SCGCQ00579583 - Write policy is not added with writeback with BBu when MFC is set SCGCQ00573077 - VD Erase will be disabled in Ctrl+R when Initlization on particular VD is aborted SCGCQ00585013 - Added the code to unset the boot-device to NONE SCGCQ00584991 - current write policy is not getting updated untill we press f5 . SCGCQ00584993 - unable to diplay the reason for difference in write policy SCGCQ00593822 - Both the Connector information(0-3 & 4-7) is not shown in PD properties while connected in Multipath SCGCQ00579600 - Write policy is not added with writeback with BBu when MFC is set SCGCQ00579607 - VD Erase will be disabled in Ctrl+R when Initlization on particular VD is aborted SCGCQ00585013 - Added the code to unset the boot-device to NONE PCLI - 1.07.05 SCGCQ00501437 - StorCLI - MR 6.2 StorCLI help syntax is wrong for R1EC SCGCQ00518543 - PCLI Sparc(1.07.02):" Cli show all" command fails with error msg "Error! App exec failed in FW PCLIError! Internal". ROMENV - 1.09 Package: 24.2.1-0021 (MR 6.2) Firmware 4.220.41-3268 SCGCQ00651072 - Battery learn cycle continues to more than one cycle even FW has marked it as bad in previous reboot SCGCQ00645802 - DIS mismatch while running system reboot script with dirty data in DDR SCGCQ00644122 - Optiomize onfi descriptor setting for offload SCGCQ00637239 - (Resolved) - FW crash while launching Ctrl+R SCGCQ00612786 - (Resolved) - Assertion failure in double DIP power cycle test case SCGCQ00604253 - Elapsed time of Patrol Read in tty log is incorrect SCGCQ00602839 - (Resolved) - Elapsed time of Reconstruction is incorrect SCGCQ00598917 - Firmware not taking "SMARTerEnabled" from NVDATA SCGCQ00598825 - (Resolved) - Rebuild triggered on an incompatible blocksize PD SCGCQ00573764 - Upgrade 3108 MR FW failing SCGCQ00569093 - PD erase does not work with SATA SSDs SCGCQ00558985 - Diagnostics failed after Drives goes to shield state SCGCQ00549095 - The DQlog.bin is getting corrupted after restarting the service of MRDiag SCGCQ00546653 - protect the removal of the device when the device is still under initialization SCGCQ00527932 - BIOS is not getting updated with the DISM progress SCGCQ00527416 - Running out of free entries in task list due to recursive addition of tasks SCGCQ00527397 - Wrong information of PD erase progress is shown by the firmware. SCGCQ00527241 - DM_DISM_LOG_SENSE state is not present in DISM SCGCQ00524801 - PI enabled VD is importing successfully even though "prevent PI Import" option is enabled SCGCQ00524040 - Change the CRC filed size SCGCQ00518855 - Fix the learn issue at powerup SCGCQ00505401 - LSI_MR Controllers fails to set "FACTORY SETTINGS" SCGCQ00503341 - VD's switch from Write Back with BBU to Write Through when an OCR is issued and BBU gets disabled. SCGCQ00503309 - Fix scheduling of hostspare correctly SCGCQ00503257 - seen DC error while running io's on 6.2 in Dev pull-push setup SCGCQ00499700 - chaos fails on R6 VD after importing failed R5 VD and one of R1 CacheCade drive SCGCQ00499455 - Defect fix for MSM doesnot show Create cachecade option SCGCQ00495896 - To fix task list overflow issue on max config setup SCGCQ00452322 - FW throws "MPT_LogDiscoveryErrors: SAS_TOPOLOGY_MAX_TOPO_PHYS_EXCEED" when connect 2 in multi-path SCGCQ00457909 - Assertion failure in ../../raid/raidpci.c at line 10522 SCGCQ00461907 - Read VPD error message on 3108 SCGCQ00464372 - Configurable drives count in iMR reflected wrongly to applications SCGCQ00466545 - wrong error code displayed and wrong error message for copyback command SCGCQ00466936 - FW hits to MonTask: while running enclosure power cycle with 4K drives SCGCQ00469174 - Issue with supercap energy calculations SCGCQ00470287 - modify scap energy calculation SCGCQ00471823 - directly attached SATA drive is not detected by controller SCGCQ00472614 - Dual Context to Single Context switching does not toggle when Cobra expanders are cascaded with EDFB enabled PHY's. SCGCQ00473420 - Defect fix for Montask observed while installing OS on JBOD SCGCQ00476945 - Controller Hangs during execution of Storcli command ''/c0 delete termlog'' SCGCQ00477266 - Battery retention test failure during contnuous loop test when there was power failure during erase SCGCQ00477667 - Battery Enable (BBE) is asserted even when BBU/Supercap not present or even when all LDs are in WT mode SCGCQ00485545 - TM timeout during enclosure pull while running heavy IO SCGCQ00486810 - Learn is not completing at powerup SCGCQ00487215 - 3TB Seagate PD size being reported as 2TB in Apps/Firmware SCGCQ00493312 - Controller Reset due to Fatal Error with RAID6/60 configuration SCGCQ00494704 - Elapsed Seconds displayed in firmware logs for background operations progress is improper SCGCQ00384656 - Kill adapter observed while running IOs on JBODs and VDs SCGCQ00614723 - CME handling of Invader SCGCQ00599798 - Issue with Global Hot Spare assignment SCGCQ00596434 - (Resolved) - Drives connected through enclosure showing wrong slot numbers. SCGCQ00580415 - issue with MR 24.1.1-003 with JBOD Mode enabled SCGCQ00557580 - (null) noticed while PD pull-push testing. SCGCQ00554546 - SMPpassthru is not happening through storlib. SCGCQ00551614 - System Reboots after issuing the OCR and kernel panic is observed SCGCQ00524812 - on breaking multipath while drives are spinnning up results in montask SCGCQ00523544 - Initialize invalid interrupt as part of intInitialize function SCGCQ00518692 - OEM server hangs after enabling EKM and rebooting. SCGCQ00505537 - Associating cachecade VD to a secured VD from Storcli does not fail. SCGCQ00496454 - Offload fails after corrupting BMT1 and BBT 2 address location SCGCQ00496422 - Adding the log event corresponding to ER SCGCQ00493492 SCGCQ00435204 - BGI kicks in on 5R5 but shows no progress at any point of time. SCGCQ00446327 - Defect fix for Unable create R0 in HII with 4K drives SCGCQ00451805 - FW-FW hit 'MonTask: line 243 in file ../../raid/1078in' while issuing OS reboot command on 9340 controller SCGCQ00470310 - CPLD input GPIO 21 driving when supercap is present and not present SCGCQ00472407 - Pinned cache gets flushed even after memory battery problem occurs. SCGCQ00474617 - VD erase restars instead of resuming after reboot. SCGCQ00477301 - Fix the cset issue SCGCQ00478707 - Cache Memory Size of controller Information is ZERO SCGCQ00484448 - Data Corruption observed while running FPIO on VDs; making-breaking multipath in overnight loop. SCGCQ00486766 - Config loss after OCR during creation of config - when the drives are still spinning up SCGCQ00486982 - Added an event to notify the user when command times out on PD SCGCQ00487803 - FDE/SED drives does not reflect as FDE/SED drives. SCGCQ00605077 - (Resolved) - "Corrected medium error" event is logged for uncorrectable mendium errors during PR SCGCQ00530495 - To declare block bad at the earliest for the safer side the number of error correction bits shall be reduced SCGCQ00504346 - Re-enable EKMS for OEM SCGCQ00421822 - System reboots continuously after flashing Firmware in Solaris _11 SCGCQ00460033 - MonTask: line 7193 in file ../../bbu/onfi.c SCGCQ00461733 - Kill adapter observed on large setup on enquiring Controller properties while drives spinning up from powersave. SCGCQ00463368 - coverity tool reported issue 13545(Wrong sizeof argument) SCGCQ00465561 - restore and flushing cache to PD are not reliable when 1st image of NF mem is corrupted SCGCQ00470502 - Firmware is allow to create slices in cachecade drivegroup using SMIS utility. SCGCQ00474005 - EKMS feature for OEM is disabled SCGCQ00474734 - max temperature bytes read from VPD is should be swapped before using SCGCQ00477996 - MR_6.2_DISM: FW hung due to DISM discovery failure on pulling the enclosure cable on reboot after running adpbattest. SCGCQ00488780 - Controller alarm continues to beep after transitioning VD from degraded to optimal state. SCGCQ00494084 - Handle OEM falut LED behavoir SCGCQ00556570 - MR6.2_iMR_fury_DM_Issue_TUR SCGCQ00524903 - In enclosure management page for DELL ,it shows some junk data in HII SCGCQ00501356 - Controller Reset due to Fatal Error with RAID6/60 configuration SCGCQ00402933 - CME logic using overlaid fields in c->rec SCGCQ00460254 - Montask appears on running IO's on 64VD's while changing LD policies SCGCQ00465672 - Enable OCR by default on GCA builds SCGCQ00480503 - MR: on FW init, controller post adapter base port missing SCGCQ00495361 - Invalid "Elapsed Seconds" value for FGI SCGCQ00531106 - Rebuild and Consistency Check aren't progressed when it is executed by CTL+R SCGCQ00518734 - Latest API changes in mr.h breaks FW compilation in mrdebug.c SCGCQ00464536 - Build Issue using GNUmakefile for MR and iMR SCGCQ00524913 - Storcli command to reset the boot ld on controller fails SCGCQ00506335 - boot block compile fails because of an erroneous macro definition SCGCQ00468366 - DATA TLB error faced while powercycle the enclosure during controller initialization SCGCQ00490696 - foreign import fails if degraded VD is present in import SCGCQ00415512 - Toolbox Console Text Display Tool SCGCQ00451314 - Porting of the PR "spin up changes to accommodate multiple power domains simultaneously" to Invader. SCGCQ00460871 - Validate the requested blocks for SCSI VERIFY commands on RAID volumes SCGCQ00466819 - IOCInit multiple Reply Descriptor Post Queue addresses SCGCQ00471500 - Firmware Change for Pre-boot management tool & boot capability for SPARC SCGCQ00477817 - add reserved fields to IO Unit Page 7 for future use SCGCQ00481549 - Disable thermal throttle changes SCGCQ00493492 - Identifying the DDR, ONFI flash and SCap combination SCGCQ00518786 - SGPIO back plane requires ramdon slot number support. SCGCQ00595486 - Increase PCIe Receiver Margin SCGCQ00595487 - Increase margin in PCIe Rx Serdes SCGCQ00438437 - obsolete SAS IO Unit Control _TRANSMIT_PORT_SELECT_SIGNAL SCGCQ00471293 - obsolete "Limit SATA max rate to 1.5 Gbps" SCGCQ00490725 - Debug Queue Implementation and Support as part of enhanced MR Diagnostic support SCGCQ00573397 - Increase the support for 32 slots SCGCQ00585068 - Add Critical event in FW to indicate that an INIT operation was halted due to reboot or other failure SCGCQ00593824 - Update code to modify GG and VPD at powerup SCGCQ00468085 - Implement throttle mechanism to prevent thermal run away SCGCQ00472399 - Change hash algorithm for cache row hash from a bit mask to a modulo SCGCQ00556564 - DIS feature SCGCQ00469990 - Signed images for FWDownload SCGCQ00342679 - Don't interpret the cachecade BVD flags if the volume is created with old FW which does not support cachecade. SCGCQ00359329 - Code-review action item for removing and updating names for AEN dism. SCGCQ00454419 - Patrol Read - no progress SCGCQ00462259 - WB Logical disks are moving to WT after corrupting BMT1,BBT1 and reboot. SCGCQ00462309 - Deep Learn is not invoked in new battery, when the system is reboot before the first learn completes SCGCQ00462327 - Transparent Learn Cycle is rescheduled even though it is not completed SCGCQ00469037 - TFM error handling : Cache policy change for WB to WT if supercap is faulty SCGCQ00469755 - Intermittent SEP errors on iMR and MR controllers SCGCQ00471540 - When Cachecade LD is deleted invalid LD details is shown in the Cachecade size changed event. SCGCQ00473330 - Hotspare Recovery Doesn't Start after Inserting Failed Drives SCGCQ00478032 - FW sending wrong configuration data during boot msg pending state SCGCQ00479443 - Upgrading from Software RAID to 9260-8i causes Alarm to sound SCGCQ00482660 - ONFI_BBM Dev test build: FwTermLog does not preserve information before powerup. SCGCQ00483590 - iMR TB Data loss when reconstructing from 1 drive R0 to 2 drive R1 with reboot SCGCQ00484771 - incorrectly uses a slot offset value to enumerate HDD. SCGCQ00485259 - In case of a certain OEM iMR shows R5 enabled. SCGCQ00492432 - MSM log warning: Controller booted in headless mode with errors SCGCQ00495888 - Set the Recovery mode page (WriteRetryCount and recoveryTimeLimit) SCGCQ00498734 - If VD is secured while reconstruction is going on does not stay secured once reconstruction is done. SCGCQ00498742 - SEAGATE hotspare drives remain spun up on LSI FW 12.12.0-0079 SCGCQ00498946 - Firmware is not updating recovery timer as intended SCGCQ00502953 - Call DDF_discardInvalidPds only if DS3 is enabled SCGCQ00518879 - LSI_MR Controllers fails to set "FACTORY SETTINGS" SCGCQ00521513 - Controller Reset due to Fatal Error with RAID6/60 configuration SCGCQ00521758 - VPD output of lspci –vvxxx showing [RV] Reserved: checksum bad, 86 byte(s) reserved SCGCQ00523958 - Multi-stripe size in each raid level of R1,r5,r6 with SAS, DIF, 4K pinned cache offline vd import cause Montask SCGCQ00523962 - Remove memory module on MR controller to downgrade to iMR does not work SCGCQ00523970 - HII critical message form/Extra character "r" with configuration not supported critical message. SCGCQ00523976 - Fw defect in PdStateSet() SCGCQ00524442 - Controller Reset due to Fatal Error with RAID6/60 configuration SCGCQ00524493 - Correct how the SCL high and low period values are calculated for the I2C to run at 400Khz SCGCQ00524494 - For new spin up code get persistent devId for drives that are connected via internal back plane. SCGCQ00526284 - Controller Reset due to Fatal Error with RAID6/60 configuration SCGCQ00526632 - Drive security mode switching in MSM SCGCQ00526633 - Unable to create another Virtual Drive when pulling first drive (degrading) in partial Virtual Drive where all drives are configured SCGCQ00549320 - Baseboard Management Controller (BMC): STP passthru command failure SCGCQ00552443 - External Key management security for iMR SCGCQ00552444 - Re-keying a controller with External Key Management(EKM) security enabled, results in a corrupted key ID. SCGCQ00554050 - Performing an online firmware update or Online Controller Reset(OCR) on a controller with External Key Management(EKM) enabled, results in all secured drives marked as foreign. SCGCQ00558051 - MR 4K Validation : 4K VD assigned to 512K CacheCade SCGCQ00559254 - Re-keying in External Key Management mode followed by disabling security and enabling LKM results in a bail out while creating a Virtual Drive SCGCQ00562800 - VD goes offline when we start reconstruction on 32 Drive R0 VD SCGCQ00566690 - Raise priority of pci config trap interrupt to critical SCGCQ00567036 - Not seeing the correct Boot Message when the connection to the External Key Management server is down SCGCQ00575842 - Switching to Local Key Management Mode(LKM) after a rekey in External Key Management(EKM) rekey without rebooting results in HII saying key incorrect but Firmware says key was created. SCGCQ00575843 - On a controller with Local Key Management(LKM) enabled, user is asked to enter the security key to unlock and import a foreign, locked and External Key Management(EKM) enabled drive. SCGCQ00579499 - FwTermLog does not preserve information before powerup. SCGCQ00579847 - Implement I2C Slave Address for Sideband Management SCGCQ00580752 - Defect Fix for VPD and inquiry callback issues in DISM SCGCQ00580771 - spin up tracker dequeue is not handled for case in which TUR error happens even after MAX retries SCGCQ00588963 - Too many unexpected sense AEN raised by CC during CME recovery on R5 SCGCQ00588964 - Too many unexpected sense AEN raised by CC during CME recovery on R5 SCGCQ00588973 - Fix GNU make file compilation SCGCQ00588977 - Routines to inject bit error in NF and ecc error in DDR for ONFI SCGCQ00588978 - Mismatch in LD id and target ID during set/reset boot device SCGCQ00588979 - Mismatch in LD id and target ID during set/reset boot device SCGCQ00593826 - Adding test routine for the bad block loop test for PR SCGCQ00423195 SCGCQ00595783 - SMART poll needs to issue log sense with page control set to current/ cummulative value SCGCQ00597425 - FW breaks if wrong security key is entered SCGCQ00604028 - on breaking the multipath in loop while drives are spinnning up will result in montask SCGCQ00604030 - FW hangs while creating 64 VDs on the controller with SLES11 SP2 PPC64 SCGCQ00604033 - While running reconstruction from R1 to 4 drive PRL11 with IO,FW hits to MonTask: line 1270 in file ../../raid/1078dm SCGCQ00604041 - Static analysis tool defect SCGCQ00604042 - Static Analysis Tool defects SCGCQ00609872 - CLI Reporting of TMM VPD SCGCQ00610801 - Rebuild triggered on an incompatible blocksize PD SCGCQ00610813 - Issue with Global Hot Spare assignment SCGCQ00610824 - Elapsed time of Reconstruction is incorrect SCGCQ00610834 - Elapsed time of Patrol Read in tty log is incorrect SCGCQ00610846 - "Corrected medium error" event is logged for uncorrectable mendium errors during PR SCGCQ00612226 - Increase margin in PCIe Rx Serdes SCGCQ00612228 - Increase PCIe Receiver Margin SCGCQ00620118 - Liberator Card loses its boot VD after many reboots SCGCQ00635628 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap. SCGCQ00638288 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset SCGCQ00646479 - Defect fix for kenel panic with iMR Fury with Free BSD driver SCGCQ00651117 - Hitting montask line 1930 in file ../../bbu/onfi.c while running FP IO's on degraded VD's SCGCQ00335860 - Cachecade configurations could not be created. SCGCQ00462330 - Deep learn doesn't start when it is requested during relaxing. SCGCQ00469041 - Write policy changed from WT to WB when the battery/Supercap is declared as bad SCGCQ00471509 - Firmware crash seen while doing continuous sas cable pull SCGCQ00471542 - Invalid "mode select(Page=0a)" issued during disk initialization phase. SCGCQ00477967 - Defect fix for Montask observed while installing OS on JBOD SCGCQ00478050 - Firmware returns asc value as 0 when failing IOs with medium errors SCGCQ00482662 - display BMU fw version in battery design info SCGCQ00482663 - Break Mirror for R10 should not be allowed SCGCQ00486553 - Medium error correction event is not logged during CC SCGCQ00498748 - 9240-4i on BCM RX67Q-6S motherboard is not getting required memory resources on boot SCGCQ00503258 - foreign import fails if degraded VD is present in import SCGCQ00504804 - L2/L3 cache error on reboot SCGCQ00514666 - search for one wire devices prints are masked after the boot SCGCQ00518020 - VPD info can't be retrieved for OEM enclosure SCGCQ00523959 - If a BOOT Passphrase is enabled with SafeStor "MegaCli adpbios dsply a0" will display "BIOS will Stop on error" even if any other mode is set. SCGCQ00523972 - Profile based VD creation - [Partial RAID options blocked until system reboot] SCGCQ00523975 - Hard coded values should be removed in TFM module SCGCQ00524802 - Fix repeated prints issue SCGCQ00559253 - A data TLB error occurs when the External Key Management Server(EKMS) is down and drive security is changed from External Key Management(EKM) mode to Local Key Management(LKM) mode. SCGCQ00563824 - HII & Ctrl-R: BGI operation still running on RAID0 VD even after PI protection disabled SCGCQ00575844 - Getting a non informative message when trying to import a Virtual Drive after a re-key without reboot SCGCQ00577296 - Deep learn will not start immediately when Relative State of Charge (RSOC) of battery is equal to 95%. SCGCQ00593485 - Raid configuration loss after reboot - PDs in POWERSAVE SCGCQ00600939 - Fix the learn issue at powerup SCGCQ00603399 - Faulty protocol used for changing the Disk Write Cache Policy SCGCQ00604029 - on breaking the multipath in loop while drives are spinnning up will result in montask SCGCQ00604031 - FW- FW hangs while creating 64 VDs on the controller with SLES11 SP2 PPC64 SCGCQ00604038 - Static Analysis Tool defects SCGCQ00604039 - Static Analysis Tool defects SCGCQ00604074 - Enabling DQ support bit in FW SCGCQ00610444 - The restore successful and unsuccessful prints to be handled properly SCGCQ00614828 - not enough bs found during double Dip power cycle Test SCGCQ00615002 - Montask in divert.c seen when injecting 64K consecutive errors on R0 VD, Patrol Read running in background. SCGCQ00615537 - Single image support for ONFI SCGCQ00635323 - Assertion failure (not enough BS found) in double DIP power cycle test case SCGCQ00651115 - DC observed upon performing OCR on a degraded R1 (AWB). SCGCQ00450647 - 9260-8i(SAS2108) hitting OOB SRAT timeout for a long time causing OOB commands to fail SCGCQ00470568 - modify scap energy calculation SCGCQ00483575 - wrong error code displayed and wrong error message for copyback command SCGCQ00485096 - Bad or Missing TMM boot message is changed to Critical error SCGCQ00498752 - 9260-16i's drive locate/fault LED header doesn't work SCGCQ00518011 - MR Controller does OCR due to Temp Buffer overflow SCGCQ00523459 - The Firmware does not change the Virtual Drives's from Write Through to Write Back after a battery manual learn cycle is complete SCGCQ00554074 - SLES 11.3 x64 Halts when Loading Kernel During Warm Reboot Stress SCGCQ00555052 - Initialize invalid interrupt as part of intInitialize function SCGCQ00567037 - Switching the security mode from External Key Management(EKM) to Local Key Management(LKM) on iMR controller will result in a corrupted controller key. SCGCQ00595833 - SMART poll needs to issue log sense with page control set to current/ cummulative value SCGCQ00604043 - Static Analysis Tool defects SCGCQ00617625 - Power removal of enclosure FW hits to MonTask: line 4056 in file ../../bbu/onfiBBM.c SCGCQ00359282 - Multiple interposer drives will not be detected by MegaRAID firmware. SCGCQ00454415 - Infinite retry happens on Test Unit command when HDD didn't respond to TU command during the initialization. SCGCQ00462149 - Secondary RAID key data page read failure 6 seen on some controllers and key vault combination SCGCQ00478428 - StorCLI_F showed firmware download failed but really took SCGCQ00481856 - Assertion failure in ../../raid/raidpci.c at line 10522 SCGCQ00484769 - FW Crash when using SCSI Passthrough SCSI_READ_10(0x28) to read 512 bytes on a RAID5 Native 4K drive. SCGCQ00492431 - When pinned cache present VD property not changing from WB to WT. SCGCQ00492433 - PDs go online without VD created & App doesn't allow any VD creation on passing a wrong parameter in Spanned VD. SCGCQ00497659 - Customer is hitting an ECC error SCGCQ00521514 - Invader: Cache Memory Size of controller Information is ZERO SCGCQ00554312 - Incorrect variable type in MR Read/Modify/Write path SCGCQ00598504 - StorCLI_F showed firmware download failed but really took SCGCQ00617620 - cache restore failure message displayed though cache restore was successfull SCGCQ00372236 - System hanged after pulling out drives from a 8Raid-6 array during OCR in Debian OS SCGCQ00454381 - Change SES Green/Amber LED behavior for OEM ACHILLES JBOD enclosure. SCGCQ00597426 - FW breaks if wrong security key is entered SCGCQ00366030 - While executing path-failover test with an SATA-SSD drive behind an interposer, the device is marked failed. SCGCQ00454368 - Card Running iMR Machine Checks when Requesting Host Memory SCGCQ00456776 - iMR FW update caused card to FW fault state and card cannot boot to OS. SCGCQ00479292 - system black screen during S1 Sleep test SCGCQ00490892 - Firmware Crash during Controller StartUp when large number of drives are connected UEFI_Driver 0x06030501 SCGCQ00478652 - Block IO tests from SCT IHV test suite failed SCGCQ00479003 - Disable Debug print in UEFI Driver SCGCQ00498925 - Not able to boot into BIOS boot menu SCGCQ00518791 - In IsValidHandle() - Free the buffer if status is not EFI success for LocateHandle SCGCQ00493654 - Memory Leak issue in UEFI driver when reconnect happens SCGCQ00483847 - Remove private GUID and use EFI_KMS_PROTOCOL_GUID defined in UEFI 2.3.1 spec SCGCQ00479016 - Disable Debug print in UEFI Driver SCGCQ00484085 - UEFI hang when SATA is connected SCGCQ00484086 - UEFI hang when SATA is connected SCGCQ00579837 - UEFI Driver should calculate checksum before setting bios data (MR_BIOS_DATA) SCGCQ00468948 - Uninstall HII CAP and Driver Health formset if platform calls Start again without calling GetHealthStatus SCGCQ00477828 - 9240/9260/9270 UEFI driver issue with RD640/RD440 platforms when user having 2TB or 4TB VD SCGCQ00477705 - 9240/9260/9270 UEFI driver issue with RD640/RD440 platforms when user having 2TB or 4TB VD SCGCQ00484113 - Follow UEFI Spec on interpreting In and Out Transfer Length that upper layer sends SCGCQ00478692 - Block IO tests from SCT IHV test suite failed SCGCQ00484114 - Follow UEFI Spec on interpreting In and Out Transfer Length that upper layer sends Hii 03.05.11.03 SCGCQ00470101 - Allow user to edit VD size (that is free form input) as it is cumbersome to modify the size using +/- SCGCQ00471830 - Save and Restore Configuration – MR SCGCQ00556209 - Transition a Thunderbolt MR controller to run in iMR mode = Controller fail in HII After Memory removed SCGCQ00556811 - When controller is in safe mode the PD menu displays inaccurate text and hangs when clicking a PD SCGCQ00579816 - HII\EKM-LKM without reboot should show proper message SCGCQ00452128 - HII cannot assign partial space less than 1 GB SCGCQ00573871 - fixing code review defects (AIM version + UCM GUID + deallocation) SCGCQ00529287 - Profile Based Raid1 Creation fails as invalid arguments SCGCQ00502940 - Naming inconsistency in option present in Create VD and Create VD - Advanced SCGCQ00482092 - condition checking is not right SCGCQ00474402 - Allows user to select EKM mode when supportEKM is set to 0 SCGCQ00485401 - Using 84 PD encl when clicking on HW, Advanced then Enclosure Management, it completly freezes the system SCGCQ00571353 - Allow user to select RAID level when controller has other VD + error handling SCGCQ00569098 - Enter security key for locked drives screen, press down to get to OK, OK will show up again on right SCGCQ00473204 - unable to show UF003 as well the first two forms + XML special character handling SCGCQ00486457 - fixing memory leak of 128 drive enclosure implementation SCGCQ00556839 - Able to select EKM even when the EKM FOD key is removed from the system. SCGCQ00505566 - Drop down option to set phy linkspeed tp 12 Gbps in HII browser is not available. SCGCQ00473186 - Save and Restore Configuration - MR w/ Premium Features (SED and Cachecade) SCGCQ00501111 - Issues when trying to change EKM security key from change security key option. SCGCQ00523869 - EKMS is down but it is still possible to select drive security in MSM and HII during creation. SCGCQ00524969 - Going from LKM to EKM asks for a Current Security key Identifier and Security key. SCGCQ00527700 - Update the latest API change in HEFU SCGCQ00571359 - UCM Phase 1: Typo "Clear Configuaration" -> "Clear Configuration" SCGCQ00500945 - EXPAND operation fails in HII for prl11 SCGCQ00494431 - Streamline the usage of max PD in limited configuration path (alias UCM) SCGCQ00494214 - Help content for Free space in Select Drive group is inappropriate SCGCQ00485932 - UCM Simple Configuration: Allow Clear Config always + Suppress Checkbox (Uf002.PDs) when VD count is >0 SCGCQ00575062 - added a while loop and take care of the multiple PD Groups scenario. SCGCQ00574041 - AIM (Agentless Inventory Manager) Issues SCGCQ00481284 - Typos in help content for profile VD for Write Policy SCGCQ00472196 - Profile based VD creation path incorrectly showing protect VD/secure VD checkbox when user clicks on drive selection criteria SCGCQ00471209 - config using 8PDs/16 partial VDs and all stripe sizes and HSPs does not restore SCGCQ00487936 - After creating a VD with UCM tool the manual configuration PD section still shows configured PDs as UG, and duplicates SCGCQ00495236 - Controller not seen in HII Browsercan after switiching from EFI WebBIOS SCGCQ00505591 - Checking the Enclosure Management settings in HII causes the system to reboot. SCGCQ00475217 - Request to support 128 drives wihin single enclosure SCGCQ00468930 - UCM Phase 2 support SCGCQ00571579 - (Implemented) - Create a formset with classGUID that customer has provided. SCGCQ00481277 - Request to change the help content for write policy in create VD form SCGCQ00415456 - Obtain the Physical Slot number from the PCI Bridge to which the Controller is connected. SCGCQ00557522 - System hang observed when the "PdInfo.userDataBlockSize" is set to 0 SCGCQ00476607 - HII cannot assign partial space less than 1 GB SCGCQ00629813 - RSOD during POST after enabling SecureBoot - HEFU.ROM should report exact size of .EFI image SCGCQ00482099 - Typos in help content for profile VD for Write Policy SCGCQ00498521 - HII cannot create a VD using unconfigured good drives as long as PD locate is set on the drives SCGCQ00477863 - Obtain the Physical Slot number from the PCI Bridge to which the Controller is connected. BIOS 6.14.05.0 SCGCQ00479507 - Getting memory conflict during boot SCGCQ00455591 - Memory access issue when loading Ctrl R SCGCQ00495471 - OOB function corrupts EBDA area used by other server function SCGCQ00552308 - not allocating memory correctly when MR and iMR are in the same system SCGCQ00493680 - Optimize reading IO port in INT15h path SCGCQ00482283 - System reboots during IO because FW didnt receive permanent host memory from OpROM SCGCQ00503046 - OpROM is displaying incorrect value for the number of INT13h device it supports SCGCQ00559094 - Provide an option to limit the max number of INT 13h devices presented to system BIOS SCGCQ00466276 - Check the controller status bit in the function which hooks INT15 SCGCQ00455597 - Allocate only two 64k SCGCQ00454086 - Add boundary checking when allocating EBDA and PMM memory for BIOS post. SCGCQ00504752 - OpROM is displaying incorrect value for the number of INT13h device it supports SCGCQ00460724 - Memory access issue for Mercury when loading Ctrl R SCGCQ00460725 - Memory allocation: Allocate only two 64k SCGCQ00501253 - OOB function corrupts EBDA area used by other server function Ctrl-R 5.03-0005 SCGCQ00485184 - Change Emergency Spare to NONE with enable enmergency on Smarter checked will fail with error=03 SCGCQ00487220 - ctrl-r dosent list all the drives to do replace drive. SCGCQ00487602 - Power savings button not enabled on Ctrl-R SCGCQ00490688 - ctrl-H doesn't list the drives to do replace drive while doing copyback in PD MGmt Screen SCGCQ00490789 - Selecting "Manage Link Speed" in CTL+R causes Fatal Error with SAS 9343-4i SCGCQ00493479 - Implemented the safe mode in Ctrl-R SCGCQ00518579 - Unable to make R10 through Ctrl R using 4k drives SCGCQ00593396 - Default (Initial) setting of VD doesn't reflect MFC's setting SCGCQ00606717 - /c0/pall show and Linkspeed information is not in same in Ctrl-R. SCGCQ00601637 - Changes in BIOS mode (pause on error) to be in sync SCGCQ00601691 - Need to display controller memory in Control-R SCGCQ00568108 - showing "BIOS Mode" in both the pages of ctrl mgmt SCGCQ00568688 - Help content is not updated with the Key stroke added SCGCQ00573077 - VD Erase will be disabled in Ctrl+R when Initlization on particular VD SCGCQ00579583 - Write policy is not added with writeback with BBu when MFC is set BootBlock 3.02.00.00-0000 SCGCQ00288393 - iMR boot Block code intial changes SCGCQ00322313 - Errbios load fails on Fury adapters SCGCQ00337925 - Merged 6.0 boot block changes to 6.1 SCGCQ00313425 - Bootblock is using NVRAM data even if NVRAM is uninitialized SCGCQ00371801 - Configure chip reset to link down SCGCQ00375108 - Added the code to enable OCM RMW errors SCGCQ00505902 - Coherency bit is disabled in SRAM TLBs NVDATA 3.1310.01-0047 Numerous changes for specific customers FCODE 4.16.08.00 SCGCQ00553069 - PCLI(1.07.05) Sparc: Command "cli set securitykey=L SCGCQ00471703 - Fcode CLI support for Invader (MR only) SCGCQ00486355 - Define and use capability bit to identify the StorCLI PCLI 1.07.05 ROMENV 1.09 ---------------------------------------------------------- Package: 24.1.1-0006 (MR 6.1) Firmware 4.210.51-3016 SCGCQ00383439 - fix for the defect - 4k drives display wrong value of Coerced size. SCGCQ00573649 - JBOD mode drive cannot be set as Bootdrive when Only JBOD Mode drive exist in MR6.1 SCGCQ00563950 - Fix for Infinite retries of command for sense code 0B/47/03 SCGCQ00523831 - controller does not boot after Cache Offload SCGCQ00521575 - (Resolved) - LSI BIOS POST displays F/W initialized percentage greater than 100% i.e 106% SCGCQ00452322 - FW throws "MPT_LogDiscoveryErrors: SAS_TOPOLOGY_MAX_TOPO_PHYS_EXCEED" when connect 2 enclosures in multi-path SCGCQ00448575 - Fix coverity defect 13424 SCGCQ00448009 - Defect Fix for Exception in Core 0 SCGCQ00440474 - MISCOMPARES FOUND DURING COPYBACK SCGCQ00433521 - boards have issue in bootup after the wait time was increased in finding the ONFI flash configuration SCGCQ00426148 - Fix the unhandled interrupt by minimizing the critical interrupt SCGCQ00422673 - FW hit Montask with line 782, L2/L3 cache error when one drive is pulled out from enclosure SCGCQ00421805 - Changes to SMARTerEnabled and SSDSMARTerEnabled are not reflected in controller properties SCGCQ00420102 - fw breaks into montask on transporting ONFI module from 4i contoller SCGCQ00419935 - Change IO time out value to 20 seconds for FW initiated IOs SCGCQ00415989 - Modify the code to support tty dump in interrupt context SCGCQ00413690 - MSM freezes until full initialization completes when configuration created SCGCQ00349837 - Sequential Read performance is less on CacheCade associated LD's. SCGCQ00567996 - ECC Errors in tty logs SCGCQ00550456 - removing the cset SCGCQ00550153: Identifying the DDR, ONFI flash and SCap combination SCGCQ00456094 - Data Corruption seen upon OCR after injecting Medium Error on Metadata of one Drive of R0 WB CCVD SCGCQ00455015 - Unblock 4G DDR support for OEM controllers SCGCQ00454330 - Capacitance value as 0% for Supercap FBU03 even though capacitor is fully charged SCGCQ00451378 - Data corruption on Raid 6 volume while running smash raw io on 63 volume SCGCQ00448581 - Coverity Defect Fix SCGCQ00442609 - NVCache fails on sCapMaxESRThreshold exceeds after a battery relearn SCGCQ00435532 - CC SRAM optimization using overlapped sections in SRAM SCGCQ00433463 - Insertion of the boot messages and the evets for montoring the ONFI backup capacity. SCGCQ00427452 - Indifference between MR.H and FW implementation for lockKeyLength SCGCQ00427326 - Boot block Version is not displayed in CTRL+R SCGCQ00421908 - Remove NO_RETENTION flag as it is not used SCGCQ00418459 - Assertion failure observed after reconstruction over from R0 to R5 SCGCQ00408827 - Raise priority of pci config trap interrupt to critical SCGCQ00396609 - Remove 4K toggle code to enable 4K support PR in 6.1. SCGCQ00558428 - Rebuild and Consistency Check aren't processed when it is executed by CTL+R SCGCQ00455583 - Memory battery problem seen while corrupting both the banks at alternative address in 8G Ptolemy. SCGCQ00452094 - Small Sequential Reads and Writes are lower than TB SCGCQ00450489 - replacePack bit is set to 1, still FW gives the battery(FBU03) status as optimal when apps queries the status SCGCQ00446931 - Firmware Version incorrectly displayed SCGCQ00446104 - MR: on doing cache offload and restore, the data loss is seen SCGCQ00427451 - bootMsgPending.needsEKM bit is not set when FW needs a key SCGCQ00423468 - ONFI: Reducing the onfi initialize time from 7sec to 2sec SCGCQ00422566 - Foreign config import fails with pinned cache when VD is migrated from one controller to another controller SCGCQ00415034 - Watchdog timer excetpion in core 1 SCGCQ00413263 - Online R6 VD became offline after another R5 VD was removed during IO with a CC2.0 VD SCGCQ00412599 - Configuring SBR for operating DDR at 800MHz does not work SCGCQ00412591 - Removal of CacheCade VD causes Hang during foreign import reports Command block Data structure issue SCGCQ00408922 - Enable watchdog timer SCGCQ00396711 - FirmWare hitting Montask with PL fault(0000d115) while trying to create R5 vd on 3drives powersavemode SCGCQ00396324 - Defect fix for Montask ../../raid/mem.c at line 280 SCGCQ00442641 - Defect fix for VD rebuild doesnot kickin and goes to foreign state after reboot SCGCQ00435715 - Loss or corruption of meta data information declares nvcache as bad and move from WB to WT SCGCQ00417354 - Firmware broke @ 639 in file ../../raid/routines for reading the puctured LBAs due to Reference Tag in PI enabled LDs. SCGCQ00415844 - Defect Fix for Montask Observed during cable pull/push SCGCQ00414361 - Inverted check for flush completion in L3CacheFlushAll SCGCQ00451974 - Unit attention for a FP IO is not handled SCGCQ00447956 - Recon progress shows improper estimated time left . SCGCQ00436260 - To resolve Failure of skinny compilation SCGCQ00415677 - Two different VDs getting same target IDs on MR controller and FW hangs SCGCQ00391804 - Firmware crash (MonTask: line 416 in file ../../dm/mpt2/mptrec.c) on reboot after installing ESX4.1U3 on VD SCGCQ00390068 - ONFI error hit when 4K sector PDs were used in CacheCade testing. SCGCQ00411644 - PD state changes from JBOD to Unconfigured Good across reboots for certain PDs SCGCQ00392627 - verification of error cases handling issues SCGCQ00434812 - Rebuild starts automatically on drive with foreign config after reboot SCGCQ00436221 - For certain OS versions, returning ASCQ=0 for TUR for an offline VD casues the storage stack to keep issuing SSU and TUR commands SCGCQ00441021 - Term log capture to include the RAID-Key phase of the boot SCGCQ00567340 - Add event in FW to indicate that an INIT operation was halted due to reboot or other failure SCGCQ00394433 - Invader Boot Volumes SCGCQ00447612 - Cobra EDFB write performance not scaling to 6400MB/s for IOs > 32k SCGCQ00434810 - Enable OCR by default in all pre-GCA builds for OEM SCGCQ00395865 - Transition of defect id SCGCQ00393644 from MR_FW_SAS3_6.0 to MR_FW_SAS3_6.1 SCGCQ00413395 - Sequential Read performance is less on CacheCade associated LD's. SCGCQ00420689 - BBU Charging gets disabled when Transparent Relearn fails to start due to low capacity SCGCQ00420710 - Implementing code review comments SCGCQ00420713 - Ability to power off and on individual HDD SCGCQ00420732 - Implementing code review comments for code collaborator review #14994 SCGCQ00420739 - Firmware is sending totalElapsedSecs value as 0 for LD and PD progresses SCGCQ00420745 - 5.7 ‘Static Code Analysis Tool’ changes SCGCQ00420749 - MonTask: line 281 in file ../../raid/mem.c if running megacli AdpDiag SCGCQ00420767 - ‘Static Code Analysis Tool’ warnings 10071, 10100, 10162, 10174, 10288, 10332, 10361, 10363, 10503 SCGCQ00433405 - Auto Foreign import fails when controller is booted with pinned cache. SCGCQ00434144 - Alarm continues to sound after copy-back is done, across reboot, from an unconfigured good drive that is used as an emergency spare. SCGCQ00434149 - Change RAID controller FW bad battery warning message that comes up during POST. SCGCQ00434151 - Setting the ASO key with storcli 1.02.08 (MegaCli 8.07.06) fails with an error code 3 on Windows or Linux if the MB BIOS PCI SCGCQ00434185 - Application could not make a JBOD bootable without a VD present SCGCQ00435943 - user is able to associate a DIF enabled VD to Cachecade SCGCQ00449870 - static variable used in PD Progress and LD Progress function which may affect multiple progresses running at the same time. SCGCQ00549466 - Cache Memory Size of controller Information is ZERO SCGCQ00549468 - Controller Reset due to Fatal Error with RAID6/60 configuration SCGCQ00550153 - Identifying the DDR, ONFI flash and SCap combination SCGCQ00550337 - Baseboard Management Controller (BMC): STP passthru command failure SCGCQ00556151 - SLES 11.3 x64 Halts when Loading Kernel During Warm Reboot Stress SCGCQ00558049 - MR 4K Validation : 4K VD assigned to 512K CacheCade SCGCQ00562722 - MR_6.2 Storlib : SMPpassthru is not happening through storlib. SCGCQ00562793 - Unable to create another Virtual Drive when pulling first drive (degrading) in partial Virtual Drive where all drives are configured SCGCQ00571048 - Elapsed Seconds displayed in firmware logs for background operations progress is improper SCGCQ00384606 - Assertion failure in ../../raid/raidpci.c at line 10011 , while running IO with medium errors on arrays. SCGCQ00420692 - The reliability and error recovery of the SuperCap firmware was improved. SCGCQ00420747 - ‘Static Code Analysis Tool’ code changes SCGCQ00420750 - ‘Static Code Analysis Tool’ Fixes: 10463, 10513, 10591, 10592 SCGCQ00420760 - Delete VD while PR still in progress cause debugger to loop. Reboot the system, debugger still loops SCGCQ00423453 - Adding check to prevent WT->WB property update for SSC VD when enableSSCWB is 0 SCGCQ00434184 - Skinny firmware does not progress background operations with certain systems when using WebBIOS in legacy mode SCGCQ00454467 - Stressing test on degrade raid with UNC drives or rebuilding on UNC drives will cause firmware hang SCGCQ00498743 - Don't interpret the cachecade BVD flags if the volume is created with old FW which does not support cachecade. SCGCQ00518877 - LSI_MR Controllers fails to set "FACTORY SETTINGS" SCGCQ00562792 - Incorrect variable type in MR Read/Modify/Write path SCGCQ00394788 - Firmware blocked firmware download to interposer SCGCQ00420686 - Firmware returns invalid data in OOB packet SCGCQ00420716 - T-bolt firmware : ECC memory error boot message and event log enhancement. SCGCQ00420757 - "Question value mismatch with Option Value" message in HII's Controller Management when in Safe Mode with pin cache SCGCQ00420764 - Grammatical spacing error in bios message at POST SCGCQ00420771 - HII /When user has a critical message and the conrtoller is in Safe Mode, going into CTRL mang will result an error msg SCGCQ00433450 - FW halts when you have pinned cahce and remove VD form the configuration. SCGCQ00452019 - Virtual drive configurations go missing during firmware upgrade from 5.3 to 5.7 SCGCQ00454364 - OEM facing with incorrect SAS HDD's indication, MSM shows 2X drives connected SCGCQ00458466 - ONFI Coverity defects : 13414,13415,13416,13417,13418,13419,13420,13421,13422 SCGCQ00558941 - Running out of free entries in task list due to recursive addition of tasks SCGCQ00420725 - 4K sector support - iMR, analyze all remaining hard-coded instances of "512" SCGCQ00434153 - Disable Band Gap feature for select customers SCGCQ00441739 - Allow Type2 DIF drive as JBOD drives SCGCQ00450979 - Incase of HW failure move to WT mode and also error case handling of flash tables SCGCQ00420724 - Port latency outlier fixes to FW (from legacy PR137246) SCGCQ00420753 - Fix code collaborator coding standard related comments for Review #18196. SCGCQ00432857 - Saved Release Note DataSLIB returning bad data as good data after host reboots SCGCQ00417871 - montask hit at the line "Fatal firmware error: Line 1057 in ../../dm/src/dm.c while running copyback SCGCQ00420744 - Provide Fastpath as a standard offering for TB based controllers SCGCQ00434156 - OEM- StorCli should not allow turning on JBOD in MR mode SCGCQ00436903 - Minimum Capacity needed for relearn is incorrect in 2208 MR FW UEFI_Driver 0x06010600 SCGCQ00478652 - Block IO tests from SCT IHV test suite failed SCGCQ00435384 - UEFI System hang if controller FW is in fault state SCGCQ00404216 - Add 3008 device ID for iMR product. SCGCQ00392836 - LSI to Support Remote Key Management SCGCQ00436609 - add PnPID's for 3004 and 3108 SCGCQ00479016 - Disable Debug print in UEFI Driver SCGCQ00484085 - platfrom has UEFI hang when SATA is connected SCGCQ00477705 - 9240/9260/9270 UEFI driver issue with platforms when user having 2TB or 4TB VD SCGCQ00484113 - Follow UEFI Spec on interpreting In and Out Transfer Length that upper layer sends Hii 03.03.10.00 SCGCQ00415826 - UCM Driver - unable to create an 8PD R5 SCGCQ00420950 - empty warning prompt is given when creating a CacheCade VD with forced writeback option SCGCQ00421615 - BBU information and propererties are not displayed in HII browser SCGCQ00421618 - HII Manage Foreign Configuration menu is not available when a foreign lockeddrive is present in the configuration. SCGCQ00423622 - Tool to generate VFR SCGCQ00423659 - UCM - Virtual Drive Configuration summary does not report the "Interface Type" SCGCQ00431622 - Navigation issue from Enable Drive Security form SCGCQ00422725 - HII doesn not allow user to use the remain free capacity to configure additional VD for R50/R10. SCGCQ00427518 - HII failed to allow user to use the remains free capacity for R1 VD with 2 plus TB capacity. SCGCQ00431231 - Hii enter black screen/timeout when user switching between fields/form sub_form to create R10 VD SCGCQ00432915 - Hii failed to report warning that inappropriate drives are picked to config R10 VD. SCGCQ00419159 - New Field "package version" in Controller Management SCGCQ00441850 - Profile based configuration help issues SCGCQ00443864 - When creating an invalid argument in HII during VD creation and after correction, save is grayed out SCGCQ00437500 - Hii failed to report error warning when config 2pds R10 with different drive capacity. SCGCQ00452128 - HII cannot assign partial space less than 1 GB SCGCQ00472196 - Profile based VD creation path incorrectly showing protect VD/secure VD checkbox when user clicks on drive selection criteria SCGCQ00452128 - HII cannot assign partial space less than 1 GB SCGCQ00477863 - Obtain the Physical Slot number from the PCI Bridge to which the Controller is connected. SCGCQ00482099 - Typos in help content for profile VD for Write Policy BIOS 6.13.00.1 SCGCQ00455591 - Memory access issue for OEM when loading Ctrl R SCGCQ00559094 - Provide an option to limit the max number of INT 13h devices presented to system BIOS SCGCQ00455597 - Memory allocation: Allocate only two 64k SCGCQ00504752 - OpROM is displaying incorrect value for the number of INT13h device it supports SCGCQ00501253 - OOB function corrupts EBDA area used by other server function Ctrl-R 5.01-0005 SCGCQ00413334 - Ctrl+R- Shows 'Power Save Mode for Configured drives' as 'Enabled' for iMR Fury controller SCGCQ00419980 - CtrlR shows option to create VDs even after configuring 16VDs in one DG. SCGCQ00436692 - Implemented the old PR LSIP200082262 with this ER in Ctrl-H SCGCQ00442610 - Firmware crashed @Line 244 in ../../raid/1078int.c for entering into CTRL-R with Pinned cache in R60 and R6. SCGCQ00461680 - ctrlR display "cache offload" as a premium feature at the place of "safe secure" feature. SCGCQ00461965 - Unable to silence the alarm SCGCQ00468676 - Aligning with FW for strip calculation for 4K drives SCGCQ00461544 - Unable to Activate the Premium feature with PFK in Ctrl+R SCGCQ00472563 - not able to create r0 WB cachecade VD in ctrl-R SCGCQ00497771 - Selecting "Manage Link Speed" in CTL+R causes Fatal Error with SAS 9343-4i SCGCQ00497772 - Power savings button not enabled on Ctrl-R SCGCQ00558344 - Boot error handling settings are not consistent for HII and CTL-R SCGCQ00558359 - Added a shortcut Ctrl+S which saves the changes and refreshes the page. SCGCQ00565105 - Implemented to list all 4 BIOS modes FCODE 4.14.05.00 NVDATA 3.1310.01-0038 Numerous changes for specific customers BootBlock 3.00.00.00-0009 ROMENV 1.09 ---------------------------------------------------------- Initial Release: Package: 24.0.2-0013 (MR 6.0.1) Firmware 4.200.21-2840 UEFI_Driver 0x06000500 Hii 03.02.11.01 BIOS 6.12.00 Ctrl-H 5.00-0007 BootBlock 3.00.00.00-0009 NVDATA 3.1304.01-0024 FCODE 4.12.05.00 ROMENV 1.09 *Third-party trademarks are the property of their respective owners.