This release note and the software that accompanies it are copyright (c) 2016, Intel Corporation or its suppliers, and may only be installed and used in accordance with the license that accompanies the software. This Software is furnished under license and may only be used or copied in accordance with the terms of that license. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. The Software is subject to change without notice, and should not be construed as a commitment by Intel Corporation or its suppliers to market, license, sell or support any product or technology. Unless otherwise provided for in the license under which this Software is provided, the Software is provided AS IS, with no warranties of any kind, express or implied. Except as expressly permitted by the Software license, neither Intel Corporation nor its suppliers assumes any responsibility or liability for any errors or inaccuracies that may appear herein. Except as expressly permitted by the Software license, no part of the Software may be reproduced, stored in a retrieval system, transmitted in any form, or distributed by any means without the express written consent of Intel Corporation. ========================== Supported RAID Controllers ========================== This download supports Intel(R) RAID controllers using SAS software stack (RMS25PB080, RMS25PB040, RMT3PB080, RMS25PB080N, RMS25CB080, RMS25CB040, RMT3CB080, RMS25CB080N, RS25AB080, RS25SB008, RS25DB080, RS25NB008), please verify that this utility has been tested with the RAID card you have chosen to use by checking the drivers web page for your controller at http://support.intel.com. =================== Package Information =================== Flash package = v23.34.0-0015 ========== Attention! ========== If using RAID Maintenance Free Backup option on your RAID Controller, the Gas Gauge component on your controller should also be updated. Please refer to the "Gas Gauge Update Procedure" pdf included in this package. If there are any questions regarding Gas Gauge upgrade, please contact Intel Support. Online Firmware Update should not be performed when downgrading from this release to a prior release. Please refer to the 240_VD_Feature_Limitations_Known_Issues_Addendum_v1.0.pdf document included with this package for additional details. Intel recommends to loading Factory Default setting after the firmware upgrade which will not affect data on any existing array. To do so: 1. Reboot the system and login to the RAID BIOS Console. 2. Select the controller and select 'Adapter Properties'->'Next' 3. Set the 'Set Factory Defaults' setting to 'Yes' and submit the change. 4. Reboot the system (the default settings are applied). 5. Re-configure to the desired settings in RAID Web Console2. ================== Known Restrictions ================== 1) This download does NOT support EFI v1.1 environment. Please use the EFI shell command ver" which will display the EFI version, to identify the EFI version. 2) When 2 or more VDs are created, VD cache settings must be the same. ======================= Contents on the package ======================= The following files are included in this zip: Name: Description: COPYING.NEWLIB.txt License Agreement ir3_2208SASHWR_FWPKG-v23.34.0-0015_readme.txt This file License_v2.pdf License Agreement MR514p2.rom Firmware binary update.bat DOS firmware update batch file update.nsh UEFI firmware update batch file CmdTool2\* Legacy CmdTool2 CLI tool for various Operating Systems StorCLI\* StorCLI CLI tool for various Operating Systems ========================== Installation instructions: ========================== UEFI (EFI 2.0) instructions for updating RAID Firmware: ----------------- 1. Download and extract all files to a local drive. 2. Boot the target system to EFI shell. 3. Change directory to the local drive and directory containing the flash update files and the firmware image file. 4. Type "update.nsh" or "efi\cmdtool2 -adpfwflash -f MR514p2.rom -noverchk -aall" 5. Wait for the flash to complete. Do NOT reboot the system during the update. Windows and Linux instructions for updating RAID Firmware: ----------------- The firmware update may be run from Within Windows or Linux using the appropriate versions of CmdTool2. In Windows, unzip the utility into the same directory as the rom file by typing "cmdtool2 -adpfwflash -f MR514p2.rom -aall". The Linux CmdTool2 by running the rpm and then calling the utility from /opt/MegaRAID/CmdTool2 as "./CmdTool2 -AdpFwFlash -f MR514p2.rom -aall" DOS instructions for updating RAID Firmware: ----------------- 1. Download and extract all files to a local drive. 2. Boot the target system to DOS. 3. Change directory to the local drive and directory containing the flash update files and the firmware image file. 4. Type "update.bat" or "dos\cmdtool2 -adpfwflash -f MR514p2.rom -aall" 5. Wait for the flash to complete. Do NOT reboot the system during the update. You can also use RAID Web Console 2 to update the RAID firmware. For more detail, please refer to the Intel(R) RAID Software User's Guide. =============== Package Details =============== Package: 23.34.0-0015 (MR 5.14 P2) Firmware 3.460.75-6373 SCGCQ00894643 - (Closed) - Controller encountered fatal error and was reset under heavy IOs and background operations. SCGCQ01063721 - (Closed) - Enabling directpdmapping causes attached disk drives to be no longer detected by storcli. SCGCQ00858151 - (Closed) - Customer reports the performance drop of the new firmware for supporting write-verify SCGCQ01007592 - (Closed) - Upgraded to MR5.14, still see "I2C 4 PID 10 SCL STUCK Low! while I2C Rx receiving data intStatus 00008000" in fw log. SCGCQ00917115 - (Closed) - Supercap "Battery Not Present" after shutdown reboot during learn cycle SCGCQ01041511 - (Closed) - Info from CLI command for bbu Mismatches with Firmware log SCGCQ01050732 - (Resolved) - CV Module FW/GG FW version no longer displayed after upgrade from 23.34.0-0005 to 23.34.0-0010 SCGCQ00995316 - (Implemented) - OEM is requesting that FastPath be enabled by default in FW SCGCQ01062955 - (Implemented) - modify ODT 120ohm into MR fw for OEM 2208 card. SCGCQ00980105 - (Implemented) - Checking in new gemini code - 14.26.20.00 SCGCQ01062956 - (Implemented) - Adding PCI IDs in firmware for OEM 2208 card. SCGCQ00970948 - (Port_Complete) - MSM shows messages with Error code 240 and no description SCGCQ00995594 - (Port_Complete) - Data miscompare found with WB R1 cachecade when IOs run overnight SCGCQ01019622 - (Port_Complete) - For SES enclosures, now we call a wrapper function to get the correct slot number before setting the bad slot bitmap. SCGCQ00928869 - (Port_Complete) - Firmware break to megamon and does not recover till manual reboot SCGCQ00937912 - (Port_Complete) - Created VD configuration with PDs released from previous VD erased will lost after next reboot SCGCQ00949550 - (Port_Complete) - SafeID changes on LSISAS3108 with repeated query using storcli SCGCQ01016071 - (Port_Complete) - MR_6.8_FW: Fw hits to MonTask: line 1272 in file ../../raid/1078dma.c while running IO in VM SCGCQ01041535 - (Port_Complete) - The Extended Sync control bit fix done for ASPM enabled systems (SCGCQ00680070) is causing Chip hang SCGCQ01016040 - (Port_Complete) - 9240-8i Wrong drives connector information (connentor: null x0) shows in MSM NVDATA 2.1507.03-0161 Various changes for different OEMs Hii 03.17.14.03 (SIGNED) SCGCQ01058140 - (Opened) - Support for RAID00 RAID-Level SCGCQ00932071 - (Port_Complete) - Inconsistency across apps for retention time in HII. SCGCQ01026959 - (Port_Complete) - HII show View foreign config when no foreign config are present SCGCQ00914259 - (Port_Complete) - HII Dashboard doesn't refresh enclosure and drive counter when an enclosure with foreign config is disconnected SCGCQ00897835 - (Port_Complete) - HII Missing WB Option SCGCQ00905879 - (Port_Complete) - MegaRAID Firmware Information not Displayed Under IMM SCGCQ00932045 - (Port_Complete) - With pinned cache HII hangs while trying to enter "cache and memory" tab under advanced controller properties SCGCQ00932117 - (Port_Complete) - DATA TLB Error(MonTask: line 245 in file) on enabling JBOD from HII while running patrol read. SCGCQ01059706 - (Port_Complete) - Unable to reconfigure RAID 0 VD to RAID 1 in HII when sufficient unconfigured good drive exists in the system. SCGCQ00931887 - (Port_Complete) - In-correct associated drive group number showing for DHS drive SCGCQ00931890 - (Port_Complete) - 'Next Learn Cycle Time' & 'Learn Period' not displayed when battery supports transparent learn. SCGCQ00911105 - (Port_Complete) - HII Firmware Update Option SCGCQ00931921 - (Port_Complete) - Display NVRAM Size only if hwpresent.nvram is present UEFI_Driver 0x06110200 (SIGNED) BIOS 5.50.03.0 WebBIOS 6.1-76-e_76-Rel FCODE 4.17.08.00 PCLI 05.07.00 BootBlockCommon 07.26.26.219 BootBlock 2.05.00.00-0010 ROMENV 1.08 Package: 23.34.0-0005 (MR 5.14 p1) Firmware - 3.460.05-4565 SCGCQ00876489 - Display Charging voltage in the superCap health event log SCGCQ00827731 - Falcon disables JBOD Mode and does not boot to JBOD drive if one of the VDs is offline SCGCQ00878611 - Incorporating latest PL Gemini binary in MR firmware SCGCQ00842327 - Foreign config is not allowed to be cleared if there is preserved cache NVDATA - 2.1507.03-0155 Hii - 03.17.14.01 SCGCQ00932071 - MR_6.10_HII: Inconsistency across apps for retention time in HII. SCGCQ00914259 - HII Dashboard doesn't refresh enclosure and drive counter when an enclosure with foreign config is disconnected SCGCQ00897835 - HII Missing WB Option SCGCQ00905879 - MegaRAID Firmware Information not Displayed Under IMM SCGCQ00932045 - MR_6.10_HII: With pinned cache HII hangs while trying to enter "cache and memory" tab under advanced controller properties SCGCQ00932117 - DATA TLB Error(MonTask: line 245 in file) on enabling JBOD from HII while running patrol read. SCGCQ00931887 - In-correct associated drive group number showing for DHS drive SCGCQ00931890 - HII: 'Next Learn Cycle Time' & 'Learn Period' not displayed when battery supports transparent learn. SCGCQ00911105 - HII Firmware Update Option SCGCQ00931921 - Display NVRAM Size only if hwpresent.nvram is presentUEFI_Driver - 0x06110200 UEFI_Driver - 0x06110200 BIOS - 5.50.03.0 WebBIOS - 6.1-76-e_76-Rel FCODE - 4.17.08.00 PCLI - 05.07.00 BootBlockCommon - 07.26.26.219 BootBlock - 2.05.00.00-0010 ROMENV - 1.08 Package: 23.34.0-0005 (MR 5.14) Firmware 3.460.05-4565 SCGCQ00827685 - (Closed) - A status of 0xFF is being returned to OEM application from StoreLib SCGCQ00830900 - (Closed) - Controller goes into a deadlock when a Logical Drive (LD) is deleted during foreground initialization SCGCQ00833144 - (Closed) - Logical drive (LD) deletion halts initialization in a multiple sliced LD configuration with LD init running on multiple LDs SCGCQ00854661 - (Closed) - 5.14 Compilation Error - Mismatch in the member name used in the code and in API SCGCQ00816594 - (Closed) - While using 4k drives and running IO'S on MegaRAID Thunderbolt controller, multiple SCSI bus resets are seen on the server. SCGCQ00819661 - (Closed) - Controller commands are getting failed resulting in application hang when Logical Drive (LD) is deleted during reconstruction SCGCQ00827055 - (Closed) - Updated Gemini version in MR firmware stream. SCGCQ00837162 - (Closed) - Megaraid Thunderbolt controller reports cache memory size as 0 when no logical drives are present. SCGCQ00838193 - (Closed) - Cache Memory size in iMR is not showing 0 SCGCQ00854914 - (Resolved) - Avoid VMWare crash when guest OS is powered on/off SCGCQ00837834 - (Closed) - BBU status says optimal but firmware logs indicate that the BBU has failed SCGCQ00876489 - (Resolved) - Display Charging voltage in the superCap health event log SCGCQ00840253 - (Closed) - Handling Functional Level Reset (FLR) . SCGCQ00848490 - (Closed) - skinny complilation error with write Verify PR SCGCQ00842350 - (Cloned_EnhReq) - WT and WB cached policies can be changed via Windows Logical Disk Properties. SCGCQ00842665 - (Implemented) - flush cache with write_verify on R0 volume and sata drive SCGCQ00856979 - (Closed) - WT and WB cached policies can be changed via Windows Logical Disk Properties. SCGCQ00858140 - (Closed) - SGPIO LED behavior updated SCGCQ00842357 - (Implemented) - Add Event Reporting for SuperCap Health After Learn Cycles SCGCQ00856580 - (Closed) - Fault LED support for predictive failure drives for SGPIO SCGCQ00842351 - (Implemented) - Removal of command blocks during Patrol Read recovery SCGCQ00803760 - (Closed) - New events for flash error handling SCGCQ00842349 - (Implemented) - Restart Patrol Read when interrupted by a consistency check SCGCQ00878611 - (Implemented) - Incorporating latest PL Gemini binary in MR firmware SCGCQ00874193 - (Port_Complete) - the performance drop of the new firmware for supporting write-verify is beyond their expectation SCGCQ00862478 - (Port_Complete) - Patrol Read Properties window does not pop up on MSM SCGCQ00840725 - (Port_Complete) - Enclosures go missing after a few expander reset cycles when connected in daisy chain SCGCQ00840631 - (Port_Complete) - MegaRAID CPLD update improvements SCGCQ00803378 - (Port_Complete) - Remove Lock/Unlock of NOR flash by iMR and MR firmware function SCGCQ00860303 - (Port_Complete) - Handling mismatch of restore data size and DRAM size SCGCQ00852649 - (Port_Complete) - MSM displays error message if 'Schedule Consistency Check' is selected. SCGCQ00826822 - (Port_Complete) - Generic RAID1 Profile based VD creation option is not grayed out after creating 64VD's. SCGCQ00816627 - (Port_Complete) - New event when patrol read is aborted due to conflict with other background operation SCGCQ00803078 - (Port_Complete) - Error Handling for Flash parts using Intel SCS command set SCGCQ00880783 - (Port_Complete) - Foreign config is not allowed to be cleared if there is preserved cache SCGCQ00838833 - (Port_Complete) - Concurrent CC cannot be started after issuing "setfactorydefaults" command. SCGCQ00824212 - (Port_Complete) - Megaraid_sas driver fails to communicate with the FW and fails to discover any disks attached SCGCQ00854668 - (Port_Complete) - L2 unrecoverable cache error was seen during Patrol read properties modification in certain conditions. SCGCQ00816088 - (Port_Complete) - Bad physical drive caused controller error recovery go in loop SCGCQ00812602 - (Port_Complete) - FW should not allow "makeSystem" when "DriveErase" is going on SCGCQ00800751 - (Port_Complete) - Flash Improvement SCGCQ00862477 - (Port_Complete) - Hot Spare disk becomes unconfigured good on reboot SCGCQ00852840 - (Port_Complete) - Updated device module parameters in firmware based on customer PnP id's SCGCQ00872121 - (Port_Complete) - Avoid VMWare crash when guest OS is powered on/off SCGCQ00854343 - (Port_Complete) - Handling Functional Level Reset (FLR) . SCGCQ00798921 - (Port_Not_Required) - Enable I2C clock frequency of 100kHz for specific OEM is not working accurately SCGCQ00818945 - (Port_Complete) - "Prepare For Removal" does not work on a PD when drive erase is in progress SCGCQ00803379 - (Port_Complete) - Read flash timeout from CFI instead of hardcoding SCGCQ00800255 - (Port_Complete) - Feature to retrieve the TTY logs compressed SCGCQ00809691 - (Port_Complete) - Change to allow configuration of I2C control registers for 100KHz vs 400 KHz bus SCGCQ00837502 - (Port_Complete) - Report controller flash device health status SCGCQ00871662 - (Port_Complete) - Falcon disables JBOD Mode and does not boot to JBOD drive if one of the VDs is offline SCGCQ00839437 - (Port_Complete) - Concurrent CC cannot be started after issuing "setfactorydefaults" command. SCGCQ00837194 - (Port_Complete) - Incorrect error returned by FW when when PDs with different block size are mixed. NVDATA 2.1507.03-0155 Various changes for different OEMs WebBIOS 6.1-76-e_76-Rel SCGCQ00846708 - (Implemented) - OEM requesting to do a WRITE VERIFY prior to flushing cache. This needs to be managed via CLI SCGCQ00847686 - (Port_Complete) - OEM requesting to do a WRITE VERIFY prior to flushing cache. This needs to be managed via CLI FCODE 4.17.08.00 SCGCQ00791238 - (Implemented) - Update Attribution Language - Copyright, Trademark, Confidentiality to Avago Hii 03.17.14.00 (SIGNED) SCGCQ00783374 - (Closed) - HII reports CCVD deleted even though its still under deletion process by FW SCGCQ00844784 - (Closed) - Handle coverity defects SCGCQ00844774 - (Closed) - Handle coverity defects SCGCQ00828751 - (Closed) - Manage ssd caching comes under vd property instead of controller property SCGCQ00828425 - (Closed) - The help string for maintain PD fail history is not appropriate SCGCQ00825573 - (Closed) - Create Cache Cade VD option still available even after MaxConfgiureSSCSize is crossed. SCGCQ00810827 - (Closed) - HII : 3 times wrong password at boot time Handle the 'Manage Foreign Configuration' page options properly with Secure JBOD present SCGCQ00795338 - (Closed) - HII: SSD caching enabled on a Recon VD . SCGCQ00896827 - (Closed) - Cannot convert the state of drive from JBOD to UG if the drive is not 16byte CDB SCGCQ00892931 - (Closed) - Not able to set Controller properties SCGCQ00880737 - (Closed) - Handled the coverity defects. SCGCQ00844160 - (Closed) - Allow CCVD Creation only if we have more than 1 GB space. SCGCQ00832946 - (Closed) - In the Reconfigure VD, suppress the Add Drives operation based on the UG drives available. SCGCQ00830577 - (Closed) - MR: on doing manage SSD caching, the landing page takes to VD management page SCGCQ00806514 - (Closed) - After entering security key it goes back to Manage Foreign config page SCGCQ00804281 - (Closed) - MR6.7:FW hangs during SVD and CCVD migration based on DDR Size SCGCQ00798739 - (Closed) - HII Server profile shows "SILENCE ALARM" instead of "SERVER" subtitle as per design SCGCQ00798657 - (Closed) - HII: Handle new changes of BBU doc related to Battery Status SCGCQ00878350 - (Closed) - HII Enclosure Management form multiple time navigation results in hang/multiple entries of enclosure seen SCGCQ00829216 - (Closed) - HII doesn't allow to reconfigure a RAID 6 partically degraded virtual drive to RAID 0 SCGCQ00825741 - (Closed) - UEFI Driver: Compilation error when debug Flags are enabled SCGCQ00811295 - (Reworked) - Generic RAID1 Profile based VD creation option is not grayed out after creating 64VD's. SCGCQ00798962 - (Closed) - When Bootable JBOD is present under controller management ''Question value mismatch with option value'' window is displayed. SCGCQ00838756 - (Closed) - Manage SSD Caching: Empty string seen in warning message SCGCQ00830579 - (Closed) - Raid level gets changed on trying to add a drive to the VD while performing Reconfigure virtual drive. SCGCQ00827376 - (Closed) - the default write policy doesn't change from WB to WT while creating a vd when there is a battery failure. SCGCQ00811352 - (Closed) - Handle Code Collaborator Defect and comments. SCGCQ00803946 - (Closed) - HII does not show HDD /SSD information for the PDs in HII Drive management and Advanced drive properties page SCGCQ00915093 - (Closed) - HII: Updating LargeIOSupport as per the new API changes SCGCQ00894460 - (Closed) - Controller status inconsistency between Dashboard and Controller management in HII SCGCQ00879673 - (Closed) - HII: Add GUID check for bootable drive SCGCQ00845541 - (Closed) - HII :Max SSC configurable size not shown SCGCQ00829208 - (Closed) - MR: In the Reconfigure VD page the help string for the 'New RAID level' is not appropriate SCGCQ00799642 - (Closed) - In copyback window the Associated Virtual Drive shows free space only for replacing drive SCGCQ00791138 - (Closed) - HII: Handle the maximum cache size value based on the max supported by FW, in the warning message shown during CCVD creation. SCGCQ00903490 - (Closed) - HII RLM for only R0 available when 18 or more drives are present SCGCQ00889780 - (Closed) - HII: Address review comments SCGCQ00879726 - (Closed) - HII: Handle the conditions for battery failed state as per the Battery design doc SCGCQ00873973 - (Closed) - Profile Based DHS creation grayed out SCGCQ00870398 - (Closed) - Incomplete Port enumeration i.e connector information is displayed for ESM and PD's in HII SCGCQ00828433 - (Closed) - No description or help for vd status field in HII SCGCQ00828427 - (Closed) - The help string for cache flush interval is not appropriate SCGCQ00811359 - (Closed) - Change the Media type before the protocol. SCGCQ00798820 - (Closed) - Does not show RAID level for CCVD in 'VD management' and 'View DG properties' pages SCGCQ00798806 - (Closed) - HII - Schedule CC right side info pane to be corrected (Add Monthly and Change Disabled to Disable as per drop down box) SCGCQ00798684 - (Closed) - HII -> Drive management does not show "Secure" when JBOD created from a SED drive SCGCQ00798579 - (Closed) - Schedule consitecny check gives invalid time when change from diable to hour, daily, weekly and monthly. SCGCQ00797318 - (Closed) - Change UCM form set title from AVAGO to LSI SCGCQ00898506 - (Closed) - OS doesn't boot after installing OS on the 100th VD , while having 240 VDs created in EFI mode SCGCQ00860564 - (Closed) - In Make UG warning message OS JBOD drives are not listed SCGCQ00810866 - (Closed) - Advanced Properties of VD are not displayed when it is Selected under Virtual Drive Management. SCGCQ00783558 - (Closed) - HII Dashboard very sluggish when you have a 240 VD foreign config SCGCQ00893928 - (Closed) - HII: Address review comments SCGCQ00881426 - (Closed) - VD properties does not display Emulation type. SCGCQ00834097 - (Closed) - HII: Option to migrate from r6 to r0 comes in HII when the VD is in degraded state. SCGCQ00808162 - (Closed) - HII allows to set 4Kn VD or 4Kn JBOD as bootable device even though legacyBIOS does not handle it SCGCQ00798824 - (Closed) - HII - NVRAM size shown as 32MB instead of 32KB SCGCQ00789492 - (Closed) - Support decimal fraction for PD/VD size in HII SCGCQ00789505 - (Closed) - HII: Replace the word enclosure with expander for 720ix SCGCQ00813457 - (Closed) - UEFI Driver: Rebranding effort for OEM SCGCQ00804071 - (Closed) - Code refactor: Check return code of HiiGetString() SCGCQ00816310 - (Implemented) - HII & MSM Mismatch on write-back options - UI Inconsistancy issue SCGCQ00827315 - (Closed) - Increase maximum cache size for Cachecade to 2048GB. This will be named CC 2.5 SCGCQ00787964 - (Closed) - HII: Address BBU/Supercap inconsistent Behavior across HSW apps. SCGCQ00804082 - (Closed) - HII reports 'Security key entered is incorrect' even though it sent this request to FW and FW report as success. SCGCQ00818583 - (Implemented) - Provide richer enclosure related information in the MegaRAID HII Enclosure Management pages. SCGCQ00819734 - (Closed) - HII : Rebranding effort for OEM SCGCQ00738144 - (Closed) - Code Redundancy in firing MR_DCMD_CTRL_GET_INFO SCGCQ00834719 - (Implemented) - PNPs and support for 16 port 12G designs SCGCQ00834720 - (Closed) - PNPs and support for 16 port 12G designs SCGCQ00844917 - (Implemented) - OEM requesting to do a WRITE VERIFY prior to flushing cache. This needs to be managed via CLI SCGCQ00789495 - (Closed) - Suppress UEFI HII Clear Configuration setting SCGCQ00816305 - (Implemented) - Add "Remove Drives" option during Raid Level Migration SCGCQ00818001 - (Implemented) - HII : Rebranding effort for OEM SCGCQ00893152 - (Closed) - HII: Add support to enable/Disable of Large IO Support SCGCQ00828031 - (Implemented) - Add support to detect that an OS is installed on a JBOD SCGCQ00765822 - (Implemented) - Display the expander firmware version under Controller properties in HII when there is an expander on the controller SCGCQ00787942 - (Implemented) - Update Attribution Language - Copyright, Trademark, Confidentiality to Avago SCGCQ00787943 - (Closed) - Update Attribution Language - Copyright, Trademark, Confidentiality to Avago SCGCQ00789504 - (Closed) - Consistency check date entry fix issue and Start Immediatley option required in SCC form SCGCQ00797917 - (Implemented) - HII: MegaRAID CPLD update improvements SCGCQ00854621 - (Closed) - Provide a more descriptive port enumeration SCGCQ00795791 - (Port_Complete) - HII Dashboard very sluggish when you have a 240 VD foreign config SCGCQ00804188 - (Port_Complete) - Syncro 2.0: Support for SED. SCGCQ00804837 - (Port_Complete) - Syncro 2.1 SSHA: Direction bit is not set for READ CAPACITY commands SCGCQ00810873 - (Port_Complete) - Deallocate the memory that was allocated for pPdList in SH_HF034_To_HF044() SCGCQ00817316 - (Port_Complete) - HII drive menu does not show 0MB drives SCGCQ00820025 - (Port_Complete) - HII Server profile shows "SILENCE ALARM" instead of "SERVER" subtitle as per design SCGCQ00804182 - (Port_Complete) - Handling code review defects SCGCQ00804191 - (Port_Complete) - Display operation mode only if supportMaintenanceMode is set SCGCQ00804835 - (Port_Complete) - UEFI Driver : SSHA boot support SCGCQ00820019 - (Port_Complete) - When Bootable JBOD is present under controller management ''Question value mismatch with option value'' window is displayed. SCGCQ00804184 - (Port_Complete) - Syncro 2.0 HII: Support for SSC & SSHA configuration. SCGCQ00820018 - (Port_Complete) - HII allows to set 4Kn VD or 4Kn JBOD as bootable device even though legacyBIOS does not handle it SCGCQ00820021 - (Port_Complete) - HII Create VD: Show error message when user clicks on Apply Change wihout choosing drive group SCGCQ00820023 - (Port_Complete) - HII: SSD caching enabled on a Recon VD . SCGCQ00888846 - (Port_Complete) - HII: Spelling mistakes in strings SCGCQ00893220 - (Port_Complete) - Inconsistency in showing controller status between MSM and HII for Fake Flash errors SCGCQ00804176 - (Port_Complete) - Incompatibility details are not displayed under HII properties SCGCQ00804185 - (Port_Complete) - Syncro 2.0 HII: Remove the option to create non-shared VD in the SSHA configuration SCGCQ00817869 - (Active) - HII: Handle CCVD Changes Based on new MR.h bit supportExtendedSSCSize SCGCQ00819694 - (Port_Complete) - 3 times wrong password at boot time Handle the 'Manage Foreign Configuration' page options properly with Secure JBOD present SCGCQ00865978 - (Port_Complete) - Pause for Password at boot time Enable/Disbale based on Boot Mode SCGCQ00878512 - (Port_Complete) - VD renaming truncates 15th character & allows for 16 characters,though only 15 supported SCGCQ00882762 - (Port_Complete) - "Question value mismatch type!Press Enter" message is displayed while entering create virtual drive page SCGCQ00791320 - (Port_Complete) - HII reports CCVD deleted even though its still under deletion process by FW SCGCQ00804187 - (Port_Complete) - Support the API change ExclusiveLDSupported to ExclusiveLDNotSupported for compatibility reasons SCGCQ00817317 - (Port_Complete) - HII does not provide assigned group array info for dedicated HSP SCGCQ00817320 - (Port_Complete) - PD Remove option is not available for offline drive SCGCQ00817323 - (Port_Complete) - Question value mismatch while Replacing Drive and while view assocaiated Drive Group SCGCQ00819701 - (Port_Complete) - After entering security key it goes back to Manage Foreign config page SCGCQ00820020 - (Port_Complete) - HII -> Drive management does not show "Secure" when JBOD created from a SED drive SCGCQ00820024 - (Port_Complete) - HII - NVRAM size shown as 32MB instead of 32KB SCGCQ00791312 - (Port_Complete) - In HII, Not able to create Spaned Virtual Disk R50,R60 Back to Back. SCGCQ00804181 - (Port_Complete) - HII - Provide support for toggling the controller to and from MAINTENANCE mode. SCGCQ00804183 - (Port_Complete) - HEFU HII : SSHA boot support SCGCQ00816978 - (Port_Complete) - Prepare For Removal" on PD does not work w/pending PD operations (HII) SCGCQ00817947 - (Port_Complete) - Enclosure properties are not accurate in HII SCGCQ00848385 - (Port_Complete) - OEM requesting to do a WRITE VERIFY prior to flushing cache. This needs to be managed via CLI SCGCQ00769769 - (Port_Complete) - Implement password EFI_IFR_FLAG_CALLBACK bit requirement from UEFI spec 2.4 Errata B SCGCQ00819329 - (Port_Complete) - HII Create VD: Show error message when user clicks on Apply Change wihout choosing drive group SCGCQ00769225 - (Port_Complete) - Syncro 2.1 SSHA: Direction bit is not set for READ CAPACITY commands SCGCQ00803516 - (Port_Complete) - HA-DAS: Add HA support to HII SCGCQ00804175 - (Port_Complete) - HAMR: HII Create VD- advance sees default as no share SCGCQ00804189 - (Port_Complete) - Syncro: VD Proprties-Advanced-GUID Value left blank and add customiztion for the string STR_FORM_HF115_PHNA_HELP SCGCQ00804190 - (Port_Complete) - CS2.0: HII : Domain ID should be displayed under High Availability properties SCGCQ00804193 - (Port_Complete) - Syncro 2.1 SSHA :Remove Provide Shared Access option of virtual drive property in HII since this option is not apply for SSHA SCGCQ00884560 - (Port_Complete) - 13G Prowl Exception Screen thrown in uEFI environment UEFI_Driver 0x06110200 (SIGNED) SCGCQ00844774 - (Closed) - Handle coverity defects SCGCQ00825741 - (Closed) - UEFI Driver: Compilation error when debug Flags are enabled SCGCQ00898506 - (Closed) - OS doesn't boot after installing OS on the 100th VD , while having 240 VDs created in EFI mode SCGCQ00813457 - (Closed) - UEFI Driver: Rebranding effort for OEM SCGCQ00834720 - (Closed) - PNPs and support for 16 port 12G designs SCGCQ00813456 - (Closed) - UEFI Driver: Rebranding effort for OEM SCGCQ00819632 - (Closed) - Rebranding effort for OEM SCGCQ00787943 - (Closed) - Update Attribution Language - Copyright, Trademark, Confidentiality to Avago SCGCQ00804837 - (Port_Complete) - Syncro 2.1 SSHA: Direction bit is not set for READ CAPACITY commands SCGCQ00804835 - (Port_Complete) - UEFI Driver : SSHA boot support BIOS 5.50.03.0 SCGCQ00879731 - (Closed) - Legacy OpROM: Handle the conditions for battery failed state as per the Battery design doc SCGCQ00809682 - (Closed) - BIOS - Shows expander as JBOD in POST SCGCQ00808086 - (Closed) - LegacyBIOS - Exposes "SecureJBOD" to system BIOS when 'Ask password at boot' entered wrongly SCGCQ00882729 - (Closed) - Legacy OpROM: Controller POST shows JBOD found on host adapter, when number of INT13 device is > deviceExposure SCGCQ00866982 - (Closed) - Legacy OpROM: Overlapping seen in POST in presence of two controllers and foreign config during CTRL-H launch SCGCQ00798656 - (Closed) - Legacy BIOS: Handle new changes of BBU doc related to Battery Status SCGCQ00808137 - (Closed) - BIOS - Line between "VDs handling" prints to be removed to match with "JBODs handling" prints SCGCQ00799339 - (Closed) - Legacy OpROM : Legacy OpROM doesn't show proper PCI slot number on OEM system. SCGCQ00845247 - (Closed) - OpROM: Overlap of controller boot messages with the footage message. SCGCQ00787941 - (Closed) - Update Attribution Language - Copyright, Trademark, Confidentiality to Avago SCGCQ00795550 - (Closed) - Legacy BIOS: Address BBU/Supercap inconsistent Behavior across HSW apps. SCGCQ00834718 - (Closed) - PNPs and support for 16 port 12G designs SCGCQ00819752 - (Port_Complete) - Legacy OpROM : Legacy OpROM doesn't show proper PCI slot number on OEM system. SCGCQ00826176 - (Port_Complete) - Legacy OpROM: 64VDs found on Host adapter eventhough more than 64 VDs are present SCGCQ00803146 - (Port_Complete) - Boot Device Selection in multi boot configuration SCGCQ00804825 - (Port_Complete) - Legacy OpROM : SSHA boot support SCGCQ00819755 - (Port_Complete) - LegacyBIOS - Exposes "SecureJBOD" to system BIOS when 'Ask password at boot' entered wrongly SCGCQ00819756 - (Port_Complete) - BIOS - Shows expander as JBOD in POST ROMENV 1.08 PCLI 05.07.00 BootBlock 2.05.00.00-0010 BootBlockCommon 07.26.26.219 Package: 23.33.0-0022 (MR 5.13 Patch) Firmware 3.450.65-4267 SCGCQ00839455 - (Closed) - MR firmware reports no smart error when attaching a PFA drive SCGCQ00831315 - (Resolved) - Setting the Learn Cycle property of iBBU09 gives an I2C error SCGCQ00830109 - (Resolved) - Foreign configuration imports fails after reconstruction on 4k sector drives. SCGCQ00841000 - (Closed) - Changing Sense retry counts for a customer video application. SCGCQ00828990 - (Closed) - Determing revision ID for superCaps without VPD programmed SCGCQ00831006 - (Port_Complete) - EFI driver health fails when more than 64VDs configured SCGCQ00811219 - (Port_Complete) - "Prepare For Removal" does not work on a PD when drive erase is in progress SCGCQ00838893 - (Port_Complete) - Cache Memory size in iMR is not showing 0 SCGCQ00838975 - (Port_Complete) - Deleting a Cachecade VD (CC VD) results in a firmware hang situation. SCGCQ00834321 - (Port_Complete) - Add support for SES RQST_OK deassertion for customer proprietary JBOD SEP SCGCQ00837600 - (Port_Complete) - Megaraid Thunderbolt controller reports cache memory size as 0 when no logical drives are present. SCGCQ00840251 - (Port_Complete) - Incorrect error returned by FW when when PDs with different block size are mixed. SCGCQ00838052 - (Port_Complete) - BBU status says optimal but firmware logs indicate that the BBU has failed SCGCQ00839437 - (Port_Complete) - Concurrent CC cannot be started after issuing "setfactorydefaults" command. WebBIOS 6.1-73-e_73-Rel ROMENV 1.08 PCLI 05.07.00 BootBlock 2.05.00.00-0010 NVDATA 2.1503.03-0148 SCGCQ00838836 - (Closed) - Set emergency hot spare as disabled by default in MFC for Intel MegaRAID 6GB based controllers SCGCQ00829038 - (Closed) - Revise Drive Spin-Up Timing on Intel 6G MR Boards SCGCQ00832541 - (Closed) - Updated NVDATA for other OEM SCGCQ00836765 - (Closed) - Disable the error annunciator (buzzer, speaker, etc) via NVDATA for other OEM SCGCQ00834322 - (Port_Complete) - Adding new xml file for specific customer BootBlockCommon 07.26.26.219 UEFI_Driver 0x060B0201 (SIGNED) Hii 03.11.08.01 (SIGNED) FCODE 4.16.08.00 BIOS 5.49.03.1 Package: 23.33.0-0018 (MR 5.13) Firmware 3.450.55-4187 SCGCQ00818418 - (Closed) - Removing OV workound for superCaps SCGCQ00816432 - (Resolved) - Battery Failure observed when upgrading FW from previous versions to latest one. SCGCQ00811123 - (Resolved) - In iMR- drive fails and becomes foreign SCGCQ00791753 - (Closed) - Removing Developer Warnings from Code. SCGCQ00788440 - (Closed) - Supercap FAULT does not get asserted until temperature reaches 75 degrees celsius SCGCQ00787155 - (Closed) - Add prints in the FW that would be helpful while debugging SCGCQ00787144 - (Closed) - FW does not import multiple VD's. SCGCQ00773103 - (Closed) - Memory corruption happening when exchaning legacy configuration information with driver. SCGCQ00773060 - (Closed) - Update Gas Gauge firmware update functionality with the ability to perform the update in a manufacturing environment as well. SCGCQ00772201 - (Closed) - CacheCade and Snapshot Virtual drives go offline after firmware upgrade/downgrade SCGCQ00771842 - (Closed) - Defect to fix coverity defect for cache cade part SCGCQ00771364 - (Closed) - Defect to fix compilation issues in 5.13 240VD SCGCQ00767988 - (Closed) - Static analysis defects SCGCQ00767681 - (Closed) - Firmware reports misleading information when the supercap charging voltage equals the learn voltage (when the HWARN bit is set) SCGCQ00766457 - (Closed) - ForceEmulation bit's value is being flipped when importing configuration from 5.11 to 5.13 firmware. SCGCQ00765430 - (Closed) - Setting appropriate target ID for Recon-Ghost LD SCGCQ00749592 - (Closed) - API change caused compilation error SCGCQ00734314 - (Resolved) - Reconstruction operation stops abnormally in legacy mode (with 64 Logical Drive restriction) SCGCQ00725840 - (Closed) - Applying consistency check changes from HII gives invalid arguments. SCGCQ00632539 - (Closed) - Firmware takes a long time to delete 240 logical drives (LDs) when the enclosure cable is removed causing a adapter kill SCGCQ00643960 - (Closed) - Unable to disable 240 VD support in FW where it is enabled SCGCQ00643962 - (Closed) - Firmware hang during virtual drive (VD) creation SCGCQ00649860 - (Closed) - Firmware breaks into montask if you boot with pinned cache SCGCQ00653949 - (Closed) - SRAM stack overflow SCGCQ00656060 - (Closed) - Rebase activity cleanup for MR 5.11 240 VD FW alpha release SCGCQ00685162 - (Closed) - Firmware fails to import foreign configuration. SCGCQ00698169 - (Closed) - FW crashes while trying to create cachecade VD SCGCQ00712470 - (Closed) - Preventing Configuration command missing boot message being issued when upgrading firmware SCGCQ00715567 - (Closed) - Rebuild operation is not triggered and invalid SGL error is seen when R1 VD is created. SCGCQ00830977 - (Closed) - Deleting a Cachecade VD (CC VD) results in a firmware hang situation. SCGCQ00825085 - (Resolved) - Upgrading from non 240 VD FW to 240 VD FW with an Online Firmware Update (OFU) results in an OS crash (when OS is on controller). SCGCQ00801649 - (Closed) - FW log does not print 'Disconnecting the SuperCap' message after the completion of CacheOffload. SCGCQ00788167 - (Closed) - Snapshot and CacheCade section offsets in DDF workspace SCGCQ00787158 - (Closed) - Backing out JBOD related changes in MR 5.13 SCGCQ00781383 - (Closed) - Updated Gemini version in MR firmware stream. SCGCQ00770263 - (Closed) - Revert changes related to CSET SCGCQ00760490 due to compilation issues SCGCQ00769385 - (Closed) - Compilation error while rebasing 5.13 240VD due to changes in LD_NVRAM_DETAIL structure. SCGCQ00765397 - (Closed) - FW crashes while attempting to insert and auto-import 238 foreign PDs SCGCQ00764331 - (Closed) - Upon opening the HII browser and staying idle afterwards , firmware log is flooded with command block details. SCGCQ00758667 - (Closed) - In iMR mode, command 'FwTermLog BBU Get' indicates that Battery is turned off even though it is executed after command 'FwTermLog BBUOn' returns success. SCGCQ00751794 - (Closed) - CacheCade handling with 240 logical drive support SCGCQ00747255 - (Closed) - Firmware crashes after disconnecting one path in a multipath configuration with 120 PD's. SCGCQ00725146 - (Closed) - Controller Firmware hits Montask when CacheCade is associated/dissociated with a RAID volume SCGCQ00718710 - (Closed) - Internal Development defect to use Bitmap prints to display the pinned_cache_present variable instead of mprintf. SCGCQ00638916 - (Closed) - Firmware breaks into Megamon while creating configuration. SCGCQ00645619 - (Closed) - Firmware is allowing to create 240 Vd's using combination of raid levels like 64 R1,64 R5 and 64 R6 etc. SCGCQ00664373 - (Closed) - Transport-ability of memory modules (TMM) SCGCQ00674388 - (Closed) - SCSI UNMAP DCDB command failes SCGCQ00675446 - (Closed) - Code review fixes for Snapshot related changes for 240 VD SCGCQ00706048 - (Closed) - FW is unresponsive after deleting a snapshot View SCGCQ00707954 - (Closed) - Firmware allows configuration to be created even if MFC settings is not correct. SCGCQ00805330 - (Closed) - HII hangs for several minutes when entering the security key in for a locked PD SCGCQ00797553 - (Closed) - Firmware breaks into megamon with DATA TLB SCGCQ00775570 - (Closed) - Compatibility feature checking - Add 240 VD feature SCGCQ00775553 - (Closed) - Defect to fix defects found by static analysis tool SCGCQ00765323 - (Closed) - Static analysis defects SCGCQ00765109 - (Closed) - Code Coverity fixes SCGCQ00764908 - (Closed) - FW prints report "Battery" references when Supercap is being used SCGCQ00725839 - (Closed) - Scheduling the check consistency operation from HII application results in a Question Value mismatch error message. SCGCQ00671362 - (Closed) - Virtual Drives (VD) are not shown in applications (MSM, StorCLI) when reconstruction is started SCGCQ00700555 - (Closed) - Making 240vd specific macro changes for MR5.12 Int code. SCGCQ00715185 - (Closed) - Storcli shows wrong message of "success" when you have ldlimit set to default and try to create R0 Vd's using autodpacache. SCGCQ00715744 - (Closed) - Virtual drive (VD) goes missing after reboot when associated with a CacheCade VD SCGCQ00788494 - (Closed) - Firmware allows invalid configuration in 240Vd mode. SCGCQ00731369 - (Closed) - FW allows importing more than the device limit if user has direct connect drives connected before inserting 238 foreign PDs SCGCQ00720002 - (Closed) - Preventing MSM from listing all the VD's in logical view with 238 VD's configured SCGCQ00635768 - (Closed) - Rebase activity cleanup SCGCQ00637759 - (Closed) - StorCLI command ldgetnum shows wrong number of LDs. SCGCQ00657763 - (Closed) - Auto Configuration only works on first inserted Physical Drive and rest come up as Unconfigured Good drives. SCGCQ00657783 - (Closed) - With Autoconfguration some VD's are coming up offline. SCGCQ00669531 - (Closed) - Firmware does not allow to create Raid1 when you have ldlimit set to default. SCGCQ00814833 - (Closed) - Gen2 - Negotiated link speed for a 6G drive when connected to Cobra Expander ( Databolt enabled phy's ) comes as 12G SCGCQ00806817 - (Closed) - MR 5.12 appears to be incompatible with early production SuperCap units sold SCGCQ00791472 - (Closed) - SuperCap does not get disconnected at the end of cache offload SCGCQ00776180 - (Closed) - Snapshot not being disabled when 240VD is enabled. SCGCQ00771696 - (Closed) - Drive Erase operation does not resume or abort in iMR mode . SCGCQ00767593 - (Closed) - TB MR mode/Breaking into montask when starting a patrol read in HII SCGCQ00648466 - (Closed) - (Gemini) Region Lock file updates SCGCQ00807700 - (Closed) - Condado Beach- FW pkg 23.22.0-0017 and later initialize drives ~50% slower SCGCQ00802309 - (Closed) - 5.13 PKG 05/Dumping information from PD that is 12GB results in a montask break SCGCQ00761127 - (Closed) - TFM FAULT assertion does not change the VDs to Write-Through(WT) mode if no flag in Safety Status is set. SCGCQ00672304 - (Closed) - Copyback operation is not allowed when the user switches from 240VD mode to 64VD mode. SCGCQ00726803 - (Closed) - CacheCade related commands should be blocked when the controller is in 240 Virtual Drives mode SCGCQ00647452 - (Closed) - Enabling snapshot and creating repository with a reboot shows adapter at baseport error and VD is not seen SCGCQ00664956 - (Closed) - Fixing code compilation for 240 VD stream. SCGCQ00630707 - (Closed) - Error during VD creation SCGCQ00815663 - (Closed) - Updating comments in Tfm Connect. SCGCQ00785210 - (Closed) - PD hotspare commissioned event being logged 16 times. SCGCQ00770850 - (Closed) - Erroneous controller feature mismatch after cache restore SCGCQ00620236 - (Implemented) - DDF module changes to support 240 Virtual Drives SCGCQ00707244 - (Closed) - Implemention to report HDD Temperature for Drives which does not support exceptional log page SCGCQ00726014 - (Closed) - Query Drive Temperature During SAS Discovery SCGCQ00654339 - (Implemented) - Firmware allows to create Hot Spare with more than 64 Logical Drive support. SCGCQ00753567 - (Implemented) - Algorithm change for assigning physical disk identification number(PD ID) SCGCQ00620235 - (Implemented) - Auto Configuration Support for 240 Virtual Drive Implementation. SCGCQ00635814 - (Closed) - SnapShot related changes for 240 VD support SCGCQ00644627 - (Implemented) - Monitor the Safety Status Register flags when fault is asserted and take appropriate actions whenever necessary. SCGCQ00764192 - (Implemented) - StorCLI show all command Capabilities section incorrectly displays that JBOD is supported SCGCQ00620226 - (Implemented) - 240LD support for TBolt MR FW-bit map changes in the code. SCGCQ00620242 - (Closed) - 240 VD support: Implementation NVRAM Migration SCGCQ00707272 - (Closed) - Drive activity can toggled by the user SCGCQ00620231 - (Implemented) - Integrating MR APIs for 240LD support into firmware - Phase-II delivery from Invader to Thunderbolt SCGCQ00655300 - (Implemented) - Switching from 64 Logical drive to 240 Logical drive for 240 Logical Drive Product Request in Thunderbolt. SCGCQ00620239 - (Closed) - DDF module misc 1 changes to support 240 VD's SCGCQ00620240 - (Implemented) - 240 VD support: NVRAM changes SCGCQ00634065 - (Port_Complete) - MR: Firmware breaks into montask on creating virtual drive on spundown drive. SCGCQ00646550 - (Port_Complete) - Auto Configuration is being created even if there is pinned cache for hot plug case SCGCQ00666004 - (Port_Complete) - Kill adapter observered while generating Pinned cache for 240VDs, on 3gig/6gig drives R0, all strip size, WB, CIO SCGCQ00759884 - (Port_Complete) - Change the comments to reflect updated offsets of struct fields due to increase in VD bitmap size, wherever applicable SCGCQ00770969 - (Port_Complete) - Unable to change policies of auto configured VDs SCGCQ00770970 - (Port_Complete) - MR_240VD: On discarding Preserved cache, Consistency Check gets initiated on VD SCGCQ00771792 - (Port_Complete) - Cant display temperature on PD that is in a failed/foreign state SCGCQ00771872 - (Port_Complete) - ForceEmulation bit's value is being flipped when importing configuration from 5.11 to 5.13 firmware. SCGCQ00775449 - (Port_Complete) - Implemented additional DDF debug information and do clean-up SCGCQ00778676 - (Port_Complete) - Instruction TLB error seen during reboot after all 240 VD's policy being changed SCGCQ00790879 - (Port_Complete) - Seagate 12G ST800FM0013 Drive Speed shows as "UNKNOWN" in MSM with 9240/9260/9270 SCGCQ00815981 - (Port_Complete) - MR 5.12 appears to be incompatible with early production SuperCap units sold SCGCQ00820940 - (Port_Complete) - Change to allow configuration of I2C control registers for 100KHz vs 400 KHz bus SCGCQ00826248 - (Port_Complete) - 240VD - LD Sync fails while installing Linux OS with inbox driver SCGCQ00826252 - (Port_Complete) - OS (CentOS 7.0) crash observed while doing online FW update on IMR Fury controller SCGCQ00639068 - (Port_Complete) - VD policy is not proper when auto Configuration direct command is fired. SCGCQ00722137 - (Port_Complete) - Added check to use old FW_RAID_MAP for iMR controllers as 240VD feature is not supported for iMR. SCGCQ00770960 - (Port_Complete) - Drives are coming as Full size 1 Drive R0 upon same drive Hot Plug SCGCQ00770962 - (Port_Complete) - Drives are detected as UG after migrating 240VD config from MR to IMR controller SCGCQ00777968 - (Port_Complete) - Patrol Read does not start and gives warning message which is not really relevant and gives the incorrect info to users. SCGCQ00783586 - (Port_Complete) - Firmware breaks after foreign configuration import SCGCQ00783596 - (Port_Complete) - Firmware breaks after foreign configuration import SCGCQ00816769 - (Port_Complete) - Firmware Work around implementation for SBR corruption issue SCGCQ00653093 - (Port_Complete) - MR6.3_240VD: With 240 VD configured updating the controller with 64 VD support driver and rebooting FW breaks in montask. SCGCQ00759937 - (Port_Complete) - Data TLB error observed while trying to import the broken VD SCGCQ00766318 - (Port_Complete) - Copyback does not start on new drive after power cycle when rebuilding on Global Hot Spare (GHS). SCGCQ00771800 - (Port_Complete) - Setting LED behavior pattern for OEM. SCGCQ00780099 - (Port_Complete) - Include learn cycle failure debug command in FW. SCGCQ00815950 - (Port_Complete) - Gen2 - Negotiated link speed for a 6G drive when connected to Cobra Expander ( Databolt enabled phy's ) comes as 12G SCGCQ00637514 - (Port_Complete) - MR: foreign import does not happen on doing pull push of enclosure. SCGCQ00649655 - (Port_Complete) - MR: On setting ldlimit to default firmware is able to import 240 virtual drives foreign configuration. SCGCQ00751635 - (Port_Complete) - Cell Disk With Status not Present Was Found to be Showing a Green Status Light SCGCQ00751734 - (Port_Complete) - Device Discovery does not complete in the case when Test Unit Read (TUR) command fails for 2 drives. SCGCQ00771803 - (Port_Complete) - Firmware performs device discovery clean up for a drive if all attempts for READ_CAPACITY fail. SCGCQ00786513 - (Port_Complete) - 0 MB drive shows up as Unconfigured Good drive. This applies to Invader/TB/Falcon. SCGCQ00796636 - (Port_Complete) - BSOD observed when tried to install OS with inbox driver using 240VD firmware SCGCQ00818738 - (Port_Complete) - While using 4k drives and running IOS an MegaRAID Thunderbolt controller, multiple SCSI bus resets are seen on the server. SCGCQ00821448 - (Port_Complete) - Controller commands are getting failed resulting in application hang when Logical Drive (LD) is deleted during reconstruction SCGCQ00712170 - (Port_Not_Required) - Prevent changing unconfigured drives to JBOD in MR SCGCQ00760490 - (Port_Complete) - Add event in FW to indicate that an INIT operation was halted due to reboot or other failure - Requested for MR 6.1/MR 5.9/M SCGCQ00768838 - (Port_Not_Required) - ForceEmulation bit's value is being flipped when importing configuration from 5.11 to 5.13 firmware. SCGCQ00780160 - (Port_Complete) - Snapshot not being disabled when 240VD is enabled. SCGCQ00781393 - (Port_Complete) - MR6.6_FW_240: Virtual Drive deleted after OCR during reconstruction SCGCQ00787503 - (Port_Complete) - Updated Gemini version in MR firmware stream. SCGCQ00791746 - (Port_Complete) - Seagate 12G ST800FM0013 Drive Speed shows as "UNKNOWN" in MSM with 9240/9260/9270 SCGCQ00815617 - (Port_Complete) - Condado Beach- FW pkg 23.22.0-0017 and later initialize drives ~50% slower SCGCQ00830297 - (Port_Complete) - MR firmware exposes more than 240 VD's to the host, even when the host driver doesn't support more than 64VD's. SCGCQ00770963 - (Port_Complete) - DDF_WORKSPACE data structure is made backward compatible SCGCQ00789466 - (Port_Complete) - StorCLI crashed when tried to enquire LD information SCGCQ00751649 - (Port_Complete) - Replaced BBU temporarily transitions to failed state SCGCQ00769251 - (Port_Complete) -(Port_Complete) - Adding a fifth enclosure fully loaded with HDD gives errorneous information BIOS 5.49.03.1 SCGCQ00769239 - (Closed) - Don't issue REAID I/O on the 4K JBOD SCGCQ00783579 - (Closed) - INT13 drive type is not set correctly for physical disk SCGCQ00769269 - (Closed) - Before calling Translate_LdTargetIdList_To_LdList set int13 drive type SCGCQ00550426 - (Closed) - Increase OpROM code size from 40k to 48k SCGCQ00819752 - (Port_Complete) - Legacy OpROM doesn't show proper PCI slot number on OEM system. SCGCQ00819755 - (Port_Complete) - Exposes "SecureJBOD" to system BIOS when 'Ask password at boot' entered wrongly SCGCQ00819756 - (Port_Complete) - BIOS - Shows expander as JBOD in POST NVDATA 2.1503.03-0143 SCGCQ00802595 - (Closed) - New LDBBM values is not loaded on firmware upgrade. SCGCQ00721178 - (Closed) - Avago removed Adaptive Read Ahead (ARA) support from FW. Need to change default Read policy to Read Ahead always. SCGCQ00816751 - (Closed) - Added NVDATA support for OEM SCGCQ00788038 - (Port_Complete) - Updated firmware configuration property values for OEM. SCGCQ00803616 - (Port_Complete) - New LDBBM values is not loaded on firmware upgrade. SCGCQ00788674 - (Port_Complete) - Added NVDATA support for OEM UEFI_Driver 0x060B0201 (SIGNED) SCGCQ00335617 - (Closed) - Drives are reporting timeout on Write Buffer cmd SCGCQ00378953 - (Closed) - HII not showing up + other enhancement for driver health formset SCGCQ00413986 - (Closed) - HII app doesnt appear when there is critical message and when platform uses SetOptions SCGCQ00479003 - (Closed) - Disable Debug print in UEFI Driver SCGCQ00638308 - (Closed) - FMP GetImageInfo could result in stack corruption - Code Review Defect ID D26304 SCGCQ00320619 - (Closed) - UEFI: Build Device Path and Get Next Target function of SCSI Pass Thru is not returning correct EFI status for certain cases SCGCQ00339371 - (Closed) - UEFI Driver fails SCT Test SCGCQ00408333 - (Closed) - UEFI: Critical boot message formatting issue SCGCQ00618669 - (Closed) - UEFI Driver: StartHiiBackEnd() has Print statement with %g SCGCQ00347171 - (Closed) - MR: on having pinned cache, the option to invoke storage dosent come. SCGCQ00384884 - (Closed) - Customize health formset + few other issues SCGCQ00395190 - (Closed) - HII - 03.02.03.00/When trying to create an R6/R5, I am unable to create though there are 3 SAS unconfigured good avail SCGCQ00396051 - (Closed) - UEFI Driver (MR 5.7) should not display finite boot messages SCGCQ00435384 - (Closed) - UEFI System hang if controller FW is in fault state SCGCQ00691044 - (Closed) - Code refactor effort: Hii Image buffer clean-up SCGCQ00343869 - (Closed) - Enhance critical boot message handling SCGCQ00369636 - (Closed) - UEFI: Settime only when FW time is not set; DHP: Return appropriate health status when there is no critical boot message SCGCQ00408094 - (Closed) - system with a critical message does not enter EFI preboot config utility SCGCQ00498925 - (Closed) - Not able to boot into BIOS boot menu in OEM server SCGCQ00688789 - (Closed) - DHP: Remove default value from numeric primitive that is present under suppressif SCGCQ00732773 - (Closed) - UEFI Driver: If the platform contains UEFI Spec Rev < than 2.3.0, then don't HII SCGCQ00756810 - (Closed) - PKG 9 HII form/When you have a a critical message such as missing VDs, after select "C" , it will show an assert SCGCQ00312683 - (Closed) - UEFI Driver not timing out in 3 mins when FW is in undefined state SCGCQ00493654 - (Closed) - Memory Leak issue in UEFI driver when reconnect happens SCGCQ00518791 - (Closed) - In IsValidHandle() - Free the buffer if status is not EFI success for LocateHandle SCGCQ00726723 - (Closed) - Ext/SCSI PassThru: UEFI Driver not filling direction flag correctly for Read SCGCQ00308870 - (Closed) - EFI Driver 518\When disconnecting the driver in EFI, I am still able to exectue the EFI utility menu. SCGCQ00715450 - (Closed) - UEFI Driver: Addressed review comments SCGCQ00262858 - (Closed) - Debug message is shown from EFI app choice prompt SCGCQ00578194 - (Closed) - UEFI Driver should calculate checksum before setting bios data (MR_BIOS_DATA) SCGCQ00601851 - (Closed) - System hang when we press F1 on second time when we are in HII form SCGCQ00696656 - (Closed) - Update Mbox value for 240VD Support SCGCQ00483847 - (Closed) - EKMS: Remove private GUID and use EFI_KMS_PROTOCOL_GUID defined in UEFI 2.3.1 spec SCGCQ00589148 - (Closed) - Diskpart EFI utility can't create partition on a JBOD SCGCQ00628310 - (Closed) - Install FMP on Controller Handle at Start() and the exception SCGCQ00340581 - (Implemented) - UEFI Driver should check pMRCtrlInfo ->maxHANodes with > 1 to determine HAMR SCGCQ00365374 - (Implemented) - Add 3108 device ID for OEM(PR SCGCQ00356047) SCGCQ00385365 - (Closed) - UEFI Driver (FoD): PCIDATA SCGCQ00285974 - (Implemented) - Add 4k secotor boot support in UEFI Driver SCGCQ00318101 - (Closed) - Timed critical boot message under UEFI mode SCGCQ00347492 - (Closed) - UEFI: Retry read capacity if scsi status is not success SCGCQ00395996 - (Closed) - UEFI Driver: Parse Boot message and remove \r\n at the beginning and replace \n with \r in other parts SCGCQ00404216 - (Closed) - Add 3008 device ID for iMR product. SCGCQ00292963 - (Implemented) - UEFI Driver: LSIP200198414/LSIP200229508/LSIP200231613: Disables all requirement for human input at boot time SCGCQ00331573 - (Closed) - MR_UEFI_Driver: Remove dependency on deprecated Driver Configuration2 protocol from UEFI Driver SCGCQ00392836 - (Closed) - LSI to Support Remote Key Management SCGCQ00526851 - (Closed) - Support EFI_FIRMWARE_MANAGEMENT_PROTOCOL for controller firmware upgrade. SCGCQ00278257 - (Implemented) - Add FoD support for 3108 for OEM SCGCQ00338066 - (Implemented) - UEFI - HAMR: Fire LD list query based on maxHANodes SCGCQ00338782 - (Implemented) - If SetOptions is called for Invader dont show EFI WebBIOS and EFI CLI option SCGCQ00436609 - (Closed) - add PnPID's for 3004 and 3108 SCGCQ00550389 - (Closed) - Write Caching HBA, JBOD/R0 supported TB controller with 240 SystemPD/LD support SCGCQ00310476 - (Implemented) - Load HII when user responds to critical boot message by pressing C SCGCQ00626601 - (Implemented) - VT-d/IOMMU support for iMR - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00650086 - (Implemented) - UEFI Driver UDK2010 complaince SCGCQ00688987 - (Port_Complete) - Don't let user boot to OS until user discards dirty cache SCGCQ00635878 - (Port_Complete) - UEFI Driver- has debug print statements during POST SCGCQ00677776 - (Port_Complete) - Initilize the buffer that we allocate to load HII and return EFI_OUT_OF_RESOURCES if allocation fails SCGCQ00484086 - (Port_Complete) - OEM platfrom has UEFI hang when SATA is connected (the issue discovered in pre-dev 13G platform) SCGCQ00756861 - (Port_Complete) - ControllerInfo[CtrlIndex].ControllerHandle got initialized incorrectly or too early SCGCQ00736761 - (Port_Complete) - Return health status failed if we have returned device error from Start() SCGCQ00678154 - (Port_Not_Required) - For OEM dont free the host memory during disconnect/unload process SCGCQ00716623 - (Port_Complete) - For OEM change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00695249 - (Port_Complete) - Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status SCGCQ00679073 - (Port_Complete) - Do not go to WebBIOS due to a bad health status when WebBIOS is disabled in NVDATA. SCGCQ00468948 - (Port_Complete) - Uninstall HII CAP and Driver Health formset if platform calls Start again without calling GetHealthStatus SCGCQ00477828 - (Port_Complete) - 9240/9260/9270 UEFI driver issue with RD640/RD440 platforms when user having 2TB or 4TB VD SCGCQ00644508 - (Port_Complete) - CPU EXCEPTION ERROR During CSIOR Stage- After Updating idrac X38 to X39 (Dont double free the memory) SCGCQ00606367 - (Port_Complete) - UEFI Driver returns EFI_NOT_FOUND when platform passes valid Target for ExtSPT.BuildDevicePath() SCGCQ00478692 - (Port_Complete) - Block IO tests from SCT IHV test suite failed SCGCQ00716622 - (Port_Complete) - For OEM dont free the host memory during disconnect/unload process SCGCQ00658168 - (Port_Complete) - Timeout is not passed correctly to FW SCGCQ00580313 - (Port_Complete) - User can't access RAID HII in UEFI mode after removing a HDD SCGCQ00484114 - (Port_Complete) - ATA PT: Follow UEFI Spec on interpreting In and Out Transfer Length that upper layer sends Hii 03.11.08.01 (SIGNED) SCGCQ00740787 - (Closed) - HII issues Add Config when there is no config SCGCQ00764936 - (Closed) - Schd CC page/Consistency Check mode does not explain the difference between sequential & concurrent SCGCQ00768459 - (Closed) - HII 5.13 PKG 01/Enclosure Management screen and Drive managment screen do not match SCGCQ00758589 - (Closed) - Reuse the string where possible and incoporate following changes suggested by tech pub SCGCQ00762860 - (Closed) - HII Dashboard/3.11.02.00/View server profile is showing two periods after the word "them" under Hardware Components SCGCQ00767605 - (Closed) - When you have a locked PD/FDE in a foreign state, it is not showing up on the dashboard only under configure SCGCQ00771730 - (Closed) - HII: Locked PD is shown in Preview Foreign Configuration form. SCGCQ00756533 - (Closed) - Remove FRU from Enclosure Management SCGCQ00762856 - (Closed) - HII Dashboard/3.11.02.00/When preview foreign config from Dashboard, it is coming up as HF034 at the top SCGCQ00783556 - (Closed) - Question value mismatch when Fan3 and 4 is selected SCGCQ00783558 - (Closed) - HII Dashboard very sluggish when you have a 240 VD foreign config SCGCQ00714530 - (Closed) - HII: Firmware Update - On selecting empty folder, hang is seen. SCGCQ00755277 - (Closed) - Change "Consistency Check" to "Make Data Consistent" for CC Rate and Stop CC on error is not changed SCGCQ00770227 - (Closed) - HII displays supercap module version as "Firmware Version" SCGCQ00771193 - (Closed) - HII: Entering security key in HII to unlock PD fails to import afterwards SCGCQ00783374 - (Closed) - HII reports CCVD deleted even though its still under deletion process by FW SCGCQ00784597 - (Closed) - HII Configuration Management Enable Security On JBOD OK button is grayed out SCGCQ00755021 - (Closed) - HII 6.6: Operation's are not refreshed in Dashboard SCGCQ00760501 - (Closed) - DashBoard HII showing 1 enclosure connected even though there are 0 connected. SCGCQ00765519 - (Closed) - HII: R5/R6 creation fails in HII from Profilebased creation SCGCQ00760435 - (Closed) - Date getting corrupted when selecting different Check Consistency Frequencie SCGCQ00765523 - (Closed) - Invader 6.6: HII : BGops fails to start when VD erase is already runnign on the other VD SCGCQ00766787 - (Closed) - HII- DHS assgining fails in presence of 240 Vds SCGCQ00768437 - (Closed) - Entering the wrong security key in HII & go back to enter the correct one the security key form should be cleared SCGCQ00684992 - (Closed) - Question about "Connected Port" in PD advance menue SCGCQ00756640 - (Closed) - MR_6.6_HII: In configuration Management creation of JBOD not possible as option to set JBOD is grey out. SCGCQ00761105 - (Closed) - Dashboard/HII 03.11.02.00/Using generic system yields spaces in HII Dash SCGCQ00764215 - (Closed) - HII 5.13 PKG 01/3.11.02.00/Preview foreign configuration screen missing words SCGCQ00765244 - (Closed) - Dashboard: comment out the referesh interval for all other fields except conroller status. SCGCQ00767138 - (Closed) - HII: Controller in Safe Mode - ASSERTs seen on console during the Preview of Foreign Configuration SCGCQ00776052 - (Closed) - 5.13 HII PKG 02/When creating a VD that is more than 1TB in size in HII, you will loose the extra space after saving the VD SCGCQ00779364 - (Closed) - Wrong drivegroup count shown with foreign config in safe mode SCGCQ00742103 - (Closed) - Remove Head Of Queue rebuild feature SCGCQ00750118 - (Closed) - Remove Head Of Queue rebuild feature SCGCQ00756784 - (Closed) - Chk the err status for HL_Get_PD_List() and HL_Get_PD_Info in UF002_PrepareData() + check Driver handle if index is valid SCGCQ00760432 - (Closed) - Getting question value mismatch when changing the Consistency check Frequency settings SCGCQ00760450 - (Closed) - HII: Need to remove Force Write Back option with CCVD creation SCGCQ00768009 - (Closed) - HII : Locked PD on controller with security disabled does not show properly when viewing under Foreign config SCGCQ00778462 - (Closed) - HII Boot time Asserts SCGCQ00819734 - (Closed) - HII : Rebranding effort for System X - Changes outside PNP ID addition SCGCQ00730596 - (Closed) - UEFI: Refreshing individual field (in this case progress field) SCGCQ00711563 - (Closed) - RRB 71 - enable SED support for iMR JBOD SCGCQ00721161 - (Closed) - SAS3: HII Create Virtual Drive advanced option defaults Protect Virtual Drive to enabled SCGCQ00712484 - (Closed) - HII. Create dashboard view as a landing form in HII SCGCQ00820020 - (Port_Complete) - HII -> Drive management does not show "Secure" when JBOD created from a SED drive SCGCQ00819694 - (Port_Complete) - HII : 3 times wrong password at boot time Handle the 'Manage Foreign Configuration' page options properly with Secure JBOD present SCGCQ00820021 - (Port_Complete) - HII Create VD: Show error message when user clicks on Apply Change wihout choosing drive group SCGCQ00820023 - (Port_Complete) - HII: SSD caching enabled on a Recon VD . SCGCQ00820025 - (Port_Complete) - HII Server profile shows "SILENCE ALARM" instead of "SERVER" subtitle as per design SCGCQ00819701 - (Port_Complete) - After entering security key it goes back to Manage Foreign config page SCGCQ00756855 - (Port_Complete) - Chk the err status for HL_Get_PD_List() and HL_Get_PD_Info in UF002_PrepareData() + check Driver handle if index is valid SCGCQ00765468 - (Port_Complete) - Hardware Component Details are not being displayed under Hardware Components SCGCQ00780729 - (Port_Complete) - Enclosure properties are not accurate in HII SCGCQ00820018 - (Port_Complete) - HII allows to set 4Kn VD or 4Kn JBOD as bootable device even though legacyBIOS does not handle it SCGCQ00820024 - (Port_Complete) - HII - NVRAM size shown as 32MB instead of 32KB SCGCQ00757730 - (Port_Complete) - Help string corrections + Suppress subtitle CACHECADE + Change Safe mode to Safe mode on errors SCGCQ00768167 - (Port_Complete) - battery's manufacture date can be set to any date in the controllers HII environment SCGCQ00820019 - (Port_Complete) - When Bootable JBOD is present under controller management ''Question value mismatch with option value'' window is displayed. SCGCQ00790204 - (Port_Complete) - 2TB and 4TB HDD show 1TB and 3TB in HII WebBIOS 6.1-73-e_73-Rel ROMENV 1.08 PCLI 05.07.00 BootBlock 2.05.00.00-0010 BootBlockCommon 07.26.26.219 FCODE 4.16.08.00 23.32.0-0017 (MR 5.12 Patch) Firmware 3.440.25-4055 SCGCQ00814833 - (Closed) - Gen2 - Negotiated link speed for a 6G drive when connected to Cobra Expander ( Databolt enabled phy's ) comes as 12G SCGCQ00807700 - (Closed) - Condado Beach- FW pkg 23.22.0-0017 and later initialize drives ~50% slower SCGCQ00815663 - (Closed) - Updating comments in Tfm Connect. SCGCQ00806817 - (Closed) - MR 5.12 appears to be incompatible with early production SuperCap units sold SCGCQ00787503 - (Port_Complete) - Updated Gemini version in MR firmware stream. SCGCQ00791746 - (Port_Complete) - Seagate 12G ST800FM0013 Drive Speed shows as "UNKNOWN" in MSM with 9240/9260/9270 BIOS 5.48.04.0 NVDATA 2.1409.03-0139 SCGCQ00802595 - (Closed) - New LDBBM values is not loaded on firmware upgrade. UEFI_Driver 0x06090700 (SIGNED) Hii v03.10.09.00 (SIGNED) WebBIOS 6.1-73-e_73-Rel ROMENV 1.08 PCLI 05.07.00 BootBlock 2.05.00.00-0010 BootBlockCommon 07.26.26.219 FCODE 4.16.08.00 23.32.0-0009 (MR5.12) Firmware 3.440.05-3712 SCGCQ00701810 - (Closed) - Update Gas Guage Safety Status register bit positions SCGCQ00712268 - (Closed) - Internal development defect to correct Module version validation logic for Gas Gauge firmware update SCGCQ00729591 - (Closed) - Preventing PatrolRead from correcting the same error LBA in loop SCGCQ00730691 - (Closed) - The cache policy of Virtual Drives(VDs) do not change to Write-Through(WT) if FAULT is asserted and there is no indication in BQ33100 Safety Status register. SCGCQ00713438 - (Closed) - FW doesn't do an Online Firmware Update (OFU) after a successful Gas Gauge firmware update . SCGCQ00726689 - (Closed) - Patrol Read operation does not resume after a reboot when using the HII application. SCGCQ00735931 - (Closed) - Device Discovery does not complete in the case when Test Unit Read (TUR) command fails for 2 drives. SCGCQ00721106 - (Closed) - Foreign Import fail after controller exchange SCGCQ00723334 - (Closed) - FW reports a partially incorrect message in the case when 5 SuperCap learns retries fail. SCGCQ00735634 - (Resolved) - Drives change to "foreign" state when FW is downgraded from MR 5.11 to MR 5.6/5.7/5.8/5.9 SCGCQ00694585 - (Closed) - MR controller stops posting with message that controller as base port not responding when you have 238 PD's spun down. SCGCQ00703521 - (Closed) - When learn fails to start, FW retries 5 more times before SuperCap is reported bad SCGCQ00707882 - (Closed) - Performing reboot immediately after updating the Gas Gauge (before learn completes) results in the FW reporting an update error on every subsequent boot. SCGCQ00715168 - (Closed) - Flashing wrong Gas Gauge image (or any bad image) will force VDs to WT(Write Through) and fail and there is no path back to WB other than rebooting SCGCQ00726641 - (Closed) - During POST message overlaps with another line. SCGCQ00667469 - (Closed) - Firmware crash is seen while trying to import VDs when there is preserved pinned cache. SCGCQ00692169 - (Closed) - Code Review fixes for an Enhancement Request SCGCQ00730541 - (Closed) - Flashing wrong Gas Gauge FW will succeed if flashed after good Gas Gauge FW is flashed and before the learn starts SCGCQ00730700 - (Closed) - Few un-acceptable prints in serial log. SCGCQ00679094 - (Closed) - Change SuperCap auto learn cycle period to 27 days and 22 hours. SCGCQ00649843 - (Closed) - Issue a complete Gas Gauge reset on every boot SCGCQ00676800 - (Closed) - Implemented Gas gauge FW update functionality . SCGCQ00679095 - (Implemented) - Reduce the monitoring time of CL (Capacitor Learning) flag in BQ33100 Operation Status register to 5Sec when a learn command is issued. SCGCQ00671027 - (Closed) - When supercap learn is pending (overdue) at boot, exposure time in WB mode is seen for up to 1 minute 5 seconds. SCGCQ00712210 - (Port_Complete) - Preventing a specific supercap error message being printed in term log SCGCQ00725140 - (Port_Complete) - Extend firmware support for the new SuperCap revisions SCGCQ00734402 - (Port_Complete) - Few un-acceptable prints in serial log. SCGCQ00734409 - (Port_Complete) - Foreign Import fail after controller exchange SCGCQ00741846 - (Port_Complete) - Drives change to "foreign" state when FW is downgraded from MR 5.11 to MR 5.6/5.7/5.8/5.9 SCGCQ00709619 - (Port_Complete) - Machine Check exception occurs during cache offload SCGCQ00712170 - (Port_Complete) - Prevent changing unconfigured drives to JBOD in MR SCGCQ00733106 - (Port_Complete) - During the AC cycle test via SAS2208 MR card with TMMA, it will halt on cached data was lost error SCGCQ00733107 - (Port_Complete) - During the AC cycle test via SAS2208 MR card with TMMA, it will halt on cached data was lost error SCGCQ00741723 - (Port_Complete) - Preventing PatrolRead from correcting the same error LBA in loop SCGCQ00741771 - (Port_Complete) - Adding a check in firmware to validate incoming configuration structure SCGCQ00685816 - (Port_Complete) - Potential data integrity issue after media error correction SCGCQ00685958 - (Port_Complete) - SSD causes system to hang at POST SCGCQ00688176 - (Port_Not_Required) - Preventing controller reset after running several hours with ASPM(Active State Power Management) enabled SCGCQ00688177 - (Port_Complete) - Preventing VD read related cache setting changes when enabling write cache setting from OS SCGCQ00725141 - (Port_Complete) - Extend firmware support for the new SuperCap revisions BIOS 5.48.04.0 SCGCQ00720411 - (Closed) - OpROM 240VD: Not able to boot to OS from the VD whose target ID is greater than 128 SCGCQ00455591 - (Closed) - Memory access issue for Mercury when loading Ctrl R SCGCQ00693494 - (Closed) - setting deviceExposure greater than or eaual to 128 will show wrong VD handled by bios SCGCQ00455597 - (Closed) - Memory allocation: Allocate only two 64k SCGCQ00736737 - (Port_Complete) - xprintf display issue when FW reports percentage for device scan SCGCQ00709995 - (Port_Complete) - OEM wants the battery status text in BIOS to change from "missing" to "N/A" for iMR solutions. WebBIOS 6.1-71-e_71-Rel NVDATA 2.1409.03-0137 Various changes for different OEMs. UEFI_Driver 0x06090700 (SIGNED) SCGCQ00691044 - (Closed) - Code refactor effort: Hii Image buffer clean-up SCGCQ00688789 - (Closed) - DHP: Remove default value from numeric primitive that is present under suppressif SCGCQ00732773 - (Closed) - UEFI Driver: If the platform contains UEFI Spec Rev < than 2.3.0, then don't HII SCGCQ00756810 - (Closed) - PKG 9 HII form/When you have a a critical message such as missing VDs, after select "C" , it will show an assert SCGCQ00726723 - (Closed) - Ext/SCSI PassThru: UEFI Driver not filling direction flag correctly for Read SCGCQ00696656 - (Closed) - Update Mbox value for 240VD Support SCGCQ00650086 - (Implemented) - UEFI Driver UDK2010 complaince SCGCQ00688987 - (Port_Complete) - Don't let user boot to OS until user discards dirty cache SCGCQ00726756 - (Port_Complete) - Implement password EFI_IFR_FLAG_CALLBACK bit requirement from UEFI spec 2.4 Errata B SCGCQ00693159 - (Port_Complete) - Return health status failed if we have returned device error from Start() SCGCQ00726831 - (Port_Complete) - Safe guard: Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status SCGCQ00736761 - (Port_Complete) - Return health status failed if we have returned device error from Start() SCGCQ00756861 - (Port_Complete) - ControllerInfo[CtrlIndex].ControllerHandle got initialized incorrectly or too early SCGCQ00695249 - (Port_Complete) - Safe guard: Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status SCGCQ00716623 - (Port_Complete) - For OEM change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00726520 - (Port_Complete) - For OEM dont free the host memory during disconnect/unload process SCGCQ00726727 - (Port_Complete) - Ext/SCSI PassThru: UEFI Driver not filling direction flag correctly for Read SCGCQ00726830 - (Port_Complete) - DHP: Remove default value from numeric primitive that is present under suppressif SCGCQ00688988 - (Port_Complete) - Don't let user boot to OS until user discards dirty cache SCGCQ00716622 - (Port_Complete) - For OEM dont free the host memory during disconnect/unload process SCGCQ00725109 - (Port_Complete) - For OEM change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00726828 - (Port_Complete) - Code refactor effort: Hii Image buffer clean-up Hii v03.10.09.00 (SIGNED) SCGCQ00689437 - (Closed) - Schedule consistency check gives an error message on Apply changes SCGCQ00692849 - (Closed) - When Controller is in Safe Mode don't remove UCM formset SCGCQ00696506 - (Closed) - Grammaical errors in HII warning message during FW Flash. SCGCQ00691938 - (Closed) - HII: Return device error when MR_DCMD_CTRL_PROPERTIES_SET fails. SCGCQ00700304 - (Closed) - MR_240VD:System fails to boot into SETUP[F2] and displays blank screen with 160 and 240 VDs SCGCQ00716628 - (Closed) - To Handle Code collab review Defect for SCGCQ00700199 SCGCQ00700199 - (Closed) - After selcting Discard pinned Cache from Controller Management, Form will be taken to Cache and Memory after success. SCGCQ00702200 - (Closed) - Firmware Update feature fails to update firmware in HII SCGCQ00709543 - (Closed) - gHiiDriver.ExtLDSupport should be Filled with appropriate value before it's used SCGCQ00702196 - (Closed) - Asserts seen before loading HII SCGCQ00704309 - (Closed) - HII: Question value mismatch message seen in Enclosure Management screen. SCGCQ00714530 - (Closed) - HII: Firmware Update - On selecting empty folder, hang is seen. SCGCQ00731567 - (Closed) - use hwPresent.memory to determine iMR SCGCQ00706817 - (Closed) - MR_240VD: Virtual Drive properties[Read/Write/IO Policy] gets changed after VD creation from HII SCGCQ00710064 - (Closed) - Handline code collaborator Defect for SCGCQ00709543 SCGCQ00716636 - (Closed) - Incomplete SAS Address SCGCQ00705577 - (Closed) - Unable to select the second enlcosure when multiple enclosures are connected to a controller . SCGCQ00723184 - (Closed) - Capacity Allocation in drive group properties is inappropriate SCGCQ00730496 - (Closed) - MR: HII gives the option to set -head of queue for raid 0 SCGCQ00742103 - (Closed) - Remove Head Of Queue rebuild feature SCGCQ00704216 - (Closed) - HII hangs on selecting "View Drive Group Properties" SCGCQ00734447 - (Closed) - Patrol read prop page gives an error message on Apply changes SCGCQ00642228 - (Implemented) - Implement Head of Queue drive rebuild for MegaRAID controllers SCGCQ00650085 - (Implemented) - HEFU HII UDK2010 complaince SCGCQ00689070 - (Closed) - MR 6.2- Negative test HII browser- Mixing unsupported drives message needs update SCGCQ00664753 - (Closed) - Ability to enable/disable JBOD mode in HII & CTRL-R SCGCQ00656614 - (Closed) - Add ability to take a VD offline, bring back VD online SCGCQ00688454 - (Implemented) - HEFU HII UDK2010 complaince SCGCQ00695063 - (Port_Complete) - Call UninstallStoreLib when we call StopControllerHiiImpl function SCGCQ00695068 - (Port_Complete) - In HII Create VD option is enabled when resconstruction is in progress (on partial VD) SCGCQ00695072 - (Port_Complete) - H730P- Not showing PD to assign as DHS to R50/ R60 VD if PD is of lesser size than largest PD in V SCGCQ00695223 - (Port_Complete) - Contents of few help messages are improper SCGCQ00728678 - (Port_Complete) - OEM UEFI creating a new VD in a "hole" in the drive group free space, hangs when viewing drive group properties SCGCQ00756855 - (Port_Complete) - Chk the err status for HL_Get_PD_List() and HL_Get_PD_Info in UF002_PrepareData() + check Driver handle if index is valid ROMENV 1.08 PCLI 05.07.00 BootBlock 2.05.00.00-0010 BootBlockCommon 07.26.26.219 FCODE 4.16.08.00 23.29.0-0016 (MR 5.11 Patch) Firmware 3.410.35-3698 SCGCQ00729591 - (Closed) - Preventing PatrolRead from correcting the same error LBA in loop SCGCQ00721106 - (Closed) - Foreign Import fail after controller exchange SCGCQ00735634 - (Resolved) - Drives change to "foreign" state when FW is downgraded from MR 5.11 to MR 5.6/5.7/5.8/5.9 SCGCQ00730700 - (Closed) - Few un-acceptable prints in serial log. SCGCQ00725140 - (Port_Complete) - Extend firmware support for the new SuperCap revisions SCGCQ00733106 - (Port_Complete) - During the AC cycle test via SAS2208 MR card with TMMA, it will halt on cached data was lost error SCGCQ00625524 - (Closed) - When we attempt to retrieve iMR Thunderbolt controller firmware logs using an application, we see some lines that are wrapped without starting on a new line. SCGCQ00628096 - (Closed) - Internal Development team defect to fix build issues related to 240 Logical Drive API changes. SCGCQ00642214 - (Closed) - Improve the Jetstress test performance. SCGCQ00647519 - (Closed) - At boot up, if a learn is required or a learn is in progress, do not wait for the SuperCap to charge. SCGCQ00649854 - (Closed) - Limit the number of retries when learn fails to start after firmware issues the learn command. SCGCQ00660171 - (Closed) - Increasing SuperCap temperature above thresholds showed no Asynchronous Event Notification (AEN) or transition of Cache Policy to Write Through (WT) SCGCQ00665853 - (Closed) - Cannot import foreign configuration. SCGCQ00681334 - (Closed) - Foreign configuration import failure for spanned array with pinned cache SCGCQ00698155 - (Closed) - Machine Check exception occurs during cache offload SCGCQ00637696 - (Closed) - Montask issue in performance test. SCGCQ00644626 - (Closed) - Increase the SuperCap learn time out value for 2GB TMM-B solution. SCGCQ00690086 - (Closed) - Foreign configuration import failure when Virtual drives (VD) with pinned cache are present SCGCQ00658701 - (Closed) - Firmware enables Dimmer Switch (DS3) Power Save Options. SCGCQ00604562 - (Closed) - Requirement to implement 512e logical drives in Tbolt. SCGCQ00634798 - (Closed) - Enable FastPath for all LSI Controllers SCGCQ00649836 - (Closed) - If cache offload happens during a relearn, then the Firmware will halt at next boot for the learn completion. SCGCQ00598902 - (Closed) - Add better debugging functionality for Alarm related field issues SCGCQ00649837 - (Closed) - Start a learn even if the SuperCap is not completely charged. SCGCQ00653995 - (Closed) - Change the cache policy of Virtual Drives(VDs) to Write Through(WT) if SuperCap temperature goes above 60 degree Celsius. SCGCQ00680070 - (Closed) - Preventing controller reset after running several hours with ASPM(Active State Power Management) enabled SCGCQ00604567 - (Closed) - Display the Command Descriptor Block(CDB) for timed out commands. SCGCQ00655345 - (Port_Complete) - RAID Ctrl. non-staggered spin-up after power saving - spin down SCGCQ00604588 - (Port_Complete) - To Disable the logging of event MR_EVT_PD_EMERGENCY_SPARE_COMMISSIONED_REMINDER SCGCQ00618569 - (Port_Complete) - HDD resume failed during dimmer switch test method. SCGCQ00619852 - (Port_Complete) - System crashes and OS boot issues with 2008 R2 based on 9280-16i4e controllers after one drive is failing in a RAID 5. SCGCQ00636774 - (Port_Complete) - IO freeze on R5 while running host IO with BGI SCGCQ00637534 - (Port_Complete) - Running Storcli /C0/CV show or (show all) starts a relearn on supercap issue SCGCQ00642963 - (Port_Complete) - Mechanism to override NVDATA Drive Activity LED setting SCGCQ00646311 - (Port_Complete) - Consistency Check media error handling is incorrect and causes data integrity issue SCGCQ00646628 - (Port_Complete) - Fix for Infinite retries of command for a particular sense code SCGCQ00651315 - (Port_Complete) - Change when checking if copyback can be done on a PD in a PRL11 SCGCQ00670882 - (Port_Complete) - Patrol read is in progress even after issuing stop patrol read command through App SCGCQ00664995 - (Port_Complete) - At boot up, if a learn is required or a learn is in progress, do not wait for the SuperCap to charge. SCGCQ00604485 - (Port_Complete) - For a particular OEM, size of some 4TB drives is reported as zero SCGCQ00628212 - (Port_Complete) - correct when copyback (replace) for R11 can be done. SCGCQ00635737 - (Port_Complete) - Enable FastPath for all LSI Controllers SCGCQ00635754 - (Port_Complete) - SMART poll needs to issue log sense with page control set to current/ cummulative value SCGCQ00646312 - (Port_Complete) - Consistency Check media error handling is incorrect and causes data integrity issue SCGCQ00668555 - (Port_Complete) - Firmware breaks into montask if you boot with pinned cache SCGCQ00635749 - (Port_Complete) - HDD resume failed during dimmer switch test method. SCGCQ00643769 - (Port_Complete) - Mechanism to override NVDATA Drive Activity LED setting SCGCQ00646299 - (Port_Complete) - Cannot recover data from a recoverable media error after Patrol Read encounters recovery failure for RAID-1 SCGCQ00646300 - (Port_Complete) - Cannot recover data from a recoverable media error after Patrol Read encounters recovery failure for RAID-1 SCGCQ00649894 - (Port_Complete) - Getting Question Value mismatch when entering Controller management screen in HII SCGCQ00652191 - (Port_Complete) - CacheCade data loss after reboot SCGCQ00652257 - (Port_Complete) - CacheCade data loss after reboot SCGCQ00503256 - (Port_Not_Required) - Montask occurs when running host i/o and parallel OOB command SCGCQ00598400 - (Port_Complete) - For a particular OEM, size of some 4TB drives is reported as zero SCGCQ00692239 - (Port_Complete) - Improve the Jetstress test performance. SCGCQ00664994 - (Port_Complete) - Increase the SuperCap learn time out value for 2GB TMM-B solution. SCGCQ00675292 - (Port_Complete) - Battery/ Memory Problems are detected and cache offload does not happen with a 2GB Memory module/ SuperCap design. SCGCQ00675291 - (Port_Complete) - Battery/ Memory Problems are detected and cache offload does not happen with a 2GB Memory module/ SuperCap design. SCGCQ00668586 - (Port_Complete) - MR 6.4:Patrol read is in progress even after issueing stop patrol read command through App BIOS 5.47.05.0 SCGCQ00626821 - (Closed) - 240VD Support: In Post Restrict to 64 VD only SCGCQ00629987 - (Closed) - With more than 64 VD's in the configuration, number of Virtual Drives handled by BIOS message is not shown in the POST. SCGCQ00659974 - (Closed) - OpROM - If there is boot message, BIOS won't detect > 64 VDs SCGCQ00662761 - (Closed) - Display Warning Message when Preboot Configuration Utility are Disabled and User tries to lunch it SCGCQ00653048 - (Closed) - AutoSelectBootLd is not working if user has OS in VD > 64 SCGCQ00632011 - (Closed) - Firmware enters faults state after a reboot on flashing firmware with IO in progress. SCGCQ00682646 - (Closed) - Display the first 64 VDs in the POST (in the same sequence we get it from FW) SCGCQ00690943 - (Implemented) - OEM wants the battery status text in BIOS to change from "missing" to "N/A" for iMR solutions. SCGCQ00626602 - (Implemented) - VT-d/IOMMU support for iMR - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00621895 - (Closed) - WebBIOS of MR card hangs due to bios control mis-direct in OEM boards SCGCQ00550388 - (Closed) - Write Caching HBA, JBOD/R0 supported TB controller with 240 SystemPD/LD support SCGCQ00644761 - (Port_Complete) - VT-d/IOMMU support for iMR - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00645908 - (Port_Complete) - Firmware enters faults state after a reboot on flashing firmware with IO in progress. SCGCQ00679070 - (Port_Complete) - Display Warning Message when Preboot Configuration Utility are Disabled and User tries to lunch it SCGCQ00697504 - (Port_Complete) - setting deviceExposure greater than or eaual to 128 will show wrong VD handled by bios UEFI_Driver 0x06080502 (SIGNED) SCGCQ00726756 - (Port_Complete) - Implement password EFI_IFR_FLAG_CALLBACK bit requirement from UEFI spec 2.4 Errata B SCGCQ00693159 - (Port_Complete) - Return health status failed if we have returned device error from Start() SCGCQ00726831 - (Port_Complete) - Safe guard: Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status SCGCQ00726520 - (Port_Complete) - For OEM dont free the host memory during disconnect/unload process SCGCQ00726727 - (Port_Complete) - Ext/SCSI PassThru: UEFI Driver not filling direction flag correctly for Read SCGCQ00726830 - (Port_Complete) - DHP: Remove default value from numeric primitive that is present under suppressif SCGCQ00688988 - (Port_Complete) - Don't let user boot to OS until user discards dirty cache SCGCQ00725109 - (Port_Complete) - For OEM change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00726828 - (Port_Complete) - Code refactor effort: Hii Image buffer clean-up SCGCQ00638308 - (Closed) - FMP GetImageInfo could result in stack corruption - Code Review Defect ID D26304 SCGCQ00628627 - (Closed) - UEFI Driver- has debug print statements during POST SCGCQ00628310 - (Closed) - Install FMP on Controller Handle at Start() and the exception SCGCQ00550389 - (Closed) - Write Caching HBA, JBOD/R0 supported TB controller with 240 SystemPD/LD support SCGCQ00626601 - (Implemented) - VT-d/IOMMU support for iMR - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00688791 - (Port_Complete) - Remove default value from numeric primitive that is present under suppressif SCGCQ00635878 - (Port_Complete) - has debug print statements during POST SCGCQ00696371 - (Port_Complete) - For OEM change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00698249 - (Port_Complete) - Don't let user boot to OS until user discards dirty cache SCGCQ00698254 - (Port_Complete) - Code refactor effort: Hii Image buffer clean-up SCGCQ00677776 - (Port_Complete) - Initilize the buffer that we allocate to load HII and return EFI_OUT_OF_RESOURCES if allocation fails SCGCQ00696543 - (Port_Complete) - VT-d/IOMMU support for iMR - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00698238 - (Port_Complete) - Do not go to WebBIOS due to a bad health status when WebBIOS is disabled in NVDATA. SCGCQ00679073 - (Port_Complete) - Do not go to WebBIOS due to a bad health status when WebBIOS is disabled in NVDATA. SCGCQ00699147 - (Port_Complete) - For OEM dont free the host memory during disconnect/unload process SCGCQ00644508 - (Port_Complete) - CPU EXCEPTION ERROR During CSIOR Stage SCGCQ00644509 - (Port_Complete) - CPU EXCEPTION ERROR During CSIOR Stage SCGCQ00644856 - (Port_Complete) - Install FMP on Controller Handle at Start() and the exception SCGCQ00661595 - (Port_Complete) - ATA Pass thru: Timeout is not passed correctly to FW SCGCQ00644859 - (Port_Complete) - FMP GetImageInfo could result in stack corruption - Code Review Defect ID D26304 SCGCQ00658168 - (Port_Complete) - ATA Pass thru: Timeout is not passed correctly to FW SCGCQ00698248 - (Port_Complete) - Initilize the buffer that we allocate to load HII and return EFI_OUT_OF_RESOURCES if allocation fails SCGCQ00698250 - (Port_Complete) - Safe guard: Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status Hii v03.09.06.00 (SIGNED) SCGCQ00625438 - (Closed) - Minor Typos and consistency issues in HEFU HII help text SCGCQ00633320 - (Closed) - Handling code collaborator Defects: SCGCQ00573222 and SCGCQ00568814 SCGCQ00602492 - (Closed) - HII 240 VD: HII fails to list the foreign configuration SCGCQ00658674 - (Closed) - Hii - Restrict the user from creating the 65th VD. SCGCQ00630532 - (Closed) - Consistency Check Start - remove mm/dd/yyyy from the string as the format is out of control of LSI SCGCQ00678695 - (Closed) - Change the Step Value to 0 for all numeric to make sure for free edit instead of Incrementing and decrementing using +/- SCGCQ00624890 - (Closed) - Handling Code Collaborator Defect: SCGCQ00573222 SCGCQ00679861 - (Closed) - Not able to create VD with 4k drives on OEM server. SCGCQ00645532 - (Closed) - Update the string for help SCGCQ00640534 - (Closed) - HII is showing RAID6 and RAID5 levels while creating VD when we have 2 512n drives and 1 4k Drives SCGCQ00678603 - (Closed) - HII does not display power state of a PD SCGCQ00637539 - (Closed) - Remove FMP installed on the controller handle in HII SCGCQ00627778 - (Closed) - Address review comments SCGCQ00672925 - (Closed) - Unable to set spinup drive count in HII SCGCQ00550390 - (Closed) - Write Caching HBA, JBOD/R0 supported TB controller with 240 SystemPD/LD support SCGCQ00626605 - (Closed) - Clone SCGCQ00556243 into the mainline SCGCQ00620259 - (Closed) - Port 240VD change to Tbolt SCGCQ00441334 SCGCQ00634019 - (Closed) - Change the default Setting of Disk Cahce Policy from Unchanged to Disable. SCGCQ00626591 - (Closed) - Add Mirror Join functionality - PR SCGCQ00521537 SCGCQ00626585 - (Closed) - Requirement for 512e implementation changes - PR SCGCQ00425778 SCGCQ00642232 - (Closed) - Ability to enable/disable JBOD mode in HII SCGCQ00621285 - (Closed) - Change the wording in HII from Check Consistency to Make data consistent SCGCQ00652171 - (Port_Complete) - HII is gave a option to start reconstruction from any degraded RAID level to RAID 0. SCGCQ00677103 - (Port_Complete) - Detail Drives info shows incorrectly in BIOS - unknown characters appearing SCGCQ00679042 - (Port_Complete) - Enhance strings for Locked foreign config import feature SCGCQ00644857 - (Port_Complete) - Remove FMP installed on the controller handle in HII SCGCQ00644858 - (Port_Complete) - RSOD during POST after enabling SecureBoot with OEM controller installed SCGCQ00661685 - (Port_Complete) - HII reports wrong data under 'Eligible JBOD Drives for conversion' while converting JBOD to UG SCGCQ00698646 - (Port_Complete) - Unable to set spinup drive count in HII SCGCQ00698664 - (Port_Complete) - Not showing PD to assign as DHS to R50/ R60 VD if PD is of lesser size than largest PD in V SCGCQ00698671 - (Port_Complete) - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties SCGCQ00652168 - (Port_Complete) - In HII ,Full initialization is not grayed out for R6 DIF arrays. SCGCQ00603251 - (Port_Complete) - Creation+ FW updation+ Scan foreign Configuration is disabled/grayed out in HII page SCGCQ00652424 - (Port_Complete) - change the numeric primitive's maximum from MAX_PHYSICAL_DRIVES to 0xff SCGCQ00698309 - (Port_Complete) - In HII ,Full initialization is not grayed out for R6 DIF arrays. SCGCQ00644788 - (Port_Complete) - Enhance help message for PD/VD Operation field SCGCQ00679036 - (Port_Complete) - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties SCGCQ00698543 - (Port_Complete) - HII is gave a option to start reconstruction from any degraded RAID level to RAID 0. SCGCQ00698650 - (Port_Complete) - HII does not display power state of a PD SCGCQ00698667 - (Port_Complete) - In HII Create VD option is enabled when resconstruction is in progress (on partial VD) SCGCQ00634684 - (Port_Complete) - RSOD during POST after enabling SecureBoot with OEM controller installed SCGCQ00644575 - (Port_Complete) - Consistency Check Start - remove mm/dd/yyyy from the string as the format is out of control of LSI SCGCQ00652169 - (Port_Complete) - HII reports wrong data under 'Eligible JBOD Drives for conversion' while converting JBOD to UG SCGCQ00693695 - (Port_Complete) - When Controller is in Safe Mode don't remove UCM formset SCGCQ00698429 - (Port_Complete) - change the numeric primitive's maximum from MAX_PHYSICAL_DRIVES to 0xff SCGCQ00698644 - (Port_Complete) - Minor Typos and consistency issues in HEFU HII help text SCGCQ00652170 - (Port_Complete) - HII is showing RAID levels, irrespective of drives to configure a new RAID level. SCGCQ00679049 - (Port_Complete) - "Make Unconfigured good" option missing in HII even if JBOD's are present in the config SCGCQ00682962 - (Port_Complete) - creation in HII is showing GB SCGCQ00698320 - (Port_Complete) - HII is showing RAID6 and RAID5 levels while creating VD when we have 2 512n drives and 1 4k Drives SCGCQ00698322 - (Port_Complete) - "Make Unconfigured good" option missing in HII even if JBOD's are present in the config SCGCQ00698447 - (Port_Complete) - Not able to create VD with 4k drives on intel wildcat server. SCGCQ00698627 - (Port_Complete) - HII is not displaying the cachecade 512GB warning message SCGCQ00644786 - (Port_Complete) - Enhance help message for PD/VD Operation field SCGCQ00682960 - (Port_Complete) - HII is not displaying the cachecade 512GB warning message SCGCQ00692302 - (Port_Complete) - TB creation in HII is showing GB SCGCQ00698547 - (Port_Complete) - HII is showing RAID levels, irrespective of drives to configure a new RAID level. SCGCQ00698661 - (Port_Complete) - Call UninstallStoreLib when we call StopControllerHiiImpl function WebBIOS 6.1-71-e_71-Rel ROMENV 1.08 PCLI 05.07.00 BootBlock 2.05.00.00-0010 NVDATA 2.1406.03-0135 Various changes for different OEMs. BootBlockCommon 07.26.26.219 FCODE 4.16.08.00 23.28.0-0015 (MR5.10 patch) Firmware 3.400.45-3507 SCGCQ00698155 - Machine Check exception occurs during cache offload SCGCQ00680070 - Preventing controller reset after running several hours with ASPM(Active State Power Management) enabled SCGCQ00618569 - HDD resume failed during dimmer switch test method. SCGCQ00646311 - Consistency Check media error handling is incorrect and can cause data integrity issue SCGCQ00670882 - Patrol read is in progress even after issuing stop patrol read command through App SCGCQ00664995 - At boot up, if a learn is required or a learn is in progress, do not wait for the SuperCap to charge. SCGCQ00643769 - Mechanism to override NVDATA Drive Activity LED setting SCGCQ00646299 - Cannot recover data from a recoverable media error after Patrol Read encounters recovery failure for RAID-1 SCGCQ00652191 - CacheCade data loss after reboot SCGCQ00598400 - For a particular OEM, size of some 4TB drives is reported as zero SCGCQ00692239 - Improve the benchmark test performance. SCGCQ00664994 - Increase the SuperCap learn time out value for 2GB TMM-B solution. SCGCQ00675291 - Battery/ Memory Problems are detected and cache offload does not happen with a 2GB Memory module/ SuperCap design. BIOS 5.46.02.1 SCGCQ00697504 - setting deviceExposure greater than or eaual to 128 will show wrong VD handled by bios SCGCQ00690943 - OEM wants the battery status text in BIOS to change from "missing" to "N/A" for iMR solutions. UEFI_Driver 0x06060A03 SCGCQ00688791 - Remove default value from numeric primitive that is present SCGCQ00698249 - Don't let user boot to OS until user discards dirty cache SCGCQ00698254 - Hii Image buffer clean-up SCGCQ00696371 - For OEM, change memory type from EfiRuntimeServicesData to EfiMemoryMappedIO SCGCQ00696543 - Implement mechanism to allow system BIOS to put entries for iMR mem allocation into proper table SCGCQ00698238 - Do not go to WebBIOS due to a bad health status when WebBIOS is disabled in NVDATA. SCGCQ00644509 - CPU EXCEPTION ERROR During CSIOR Stage- After Updating idrac X38 to X39 (Dont double free the memory) SCGCQ00644856 - Install FMP on Controller Handle at Start() and the exception SCGCQ00661595 - Timeout is not passed correctly to FW SCGCQ00644859 - FMP GetImageInfo could result in stack corruption SCGCQ00698248 - Initilize the buffer that we allocate to load HII and return EFI_OUT_OF_RESOURCES if allocation fails SCGCQ00698250 - Return health status failed if platform calls GetHealthStatus w/ NULL handle after we return intermediate status SCGCQ00699147 - For OEM, don't free the host memory during disconnect/unload process Hii 03.07.12.02 SCGCQ00642232 - Ability to enable/disable JBOD mode in HII SCGCQ00644857 - Remove FMP installed on the controller handle in HII SCGCQ00644858 - RSOD during POST after enabling SecureBoot SCGCQ00661685 - HII reports wrong data under 'Eligible JBOD Drives for conversion' while converting JBOD to UG SCGCQ00698646 - Unable to set spinup drive count in HII SCGCQ00698664 - Not showing PD to assign as DHS to R50/ R60 VD if PD is of lesser size than largest PD SCGCQ00698671 - After Rebuilding, DHS and Expand VD operations failed to update as per VD properties SCGCQ00698309 - In HII ,Full initialization is not grayed out for R6 DIF arrays. SCGCQ00698543 - HII is gave a option to start reconstruction from any degraded RAID level to RAID 0. SCGCQ00698650 - HII does not display power state of a PD SCGCQ00698667 - In HII Create VD option is enabled when resconstruction is in progress (on partial VD) SCGCQ00644575 - Consistency Check Start - remove mm/dd/yyyy from the string as the format is out of control of LSI SCGCQ00693695 - When Controller is in Safe Mode don't remove UCM formset SCGCQ00698429 - change the numeric primitive's maximum from MAX_PHYSICAL_DRIVES to 0xff SCGCQ00698644 - Minor Typos and consistency issues in HEFU HII help text SCGCQ00698322 - "Make Unconfigured good" option missing in HII even if JBOD's are present in the config SCGCQ00698320 - HII is showing RAID6 and RAID5 levels while creating VD when we have 2 512n drives and 1 4k Drives SCGCQ00698447 - Not able to create VD with 4k drives SCGCQ00698627 - not displaying the cachecade 512GB warning message SCGCQ00644786 - Enhance help message for PD/VD Operation field SCGCQ00692302 - creation in HII is showing GB SCGCQ00698547 - HII is showing RAID levels, irrespective of drives to configure a new RAID level. SCGCQ00698661 - Call UninstallStoreLib when we call StopControllerHiiImpl function WebBIOS 6.1-72-e_72-01-Rel SCGCQ00666796 - 9270 is not able to create RAID10 after CacheCade SSD VD created ROMENV 1.08 PCLI 05.07.00 BootBlock 2.05.00.00-0010 NVDATA 2.1403.03-0133 Various changes for different OEMs. BootBlockCommon 07.26.26.219 FCODE 4.16.08.00 23.28.0-0010 (MR5.10) Firmware - 3.400.05-3175 SCGCQ00482123 - External Key management security for iMR SCGCQ00499663 - Not seeing the correct Boot Message when the connection to the External Key Management server is down SCGCQ00518723 - Re-keying a controller with External Key Management(EKM) security enabled, results in a corrupted key ID. SCGCQ00523211 - Performing an online firmware update or Online Controller Reset(OCR) on a controller with External Key Management(EKM) enabled, results in all secured drives marked as foreign. SCGCQ00552222 - Raid configuration loss after reboot - PDs in POWERSAVE SCGCQ00557797 - Re-keying in External Key Management mode followed by disabling security and enabling LKM results in a bail out while creating a Virtual Drive SCGCQ00563760 - FW debugger scrolls continuous message and eventually resets after deleting Source VD during a Cachecade disassocation SCGCQ00569173 - Switching to Local Key Management Mode(LKM) after a rekey in External Key Management(EKM) rekey without rebooting results in HII saying key incorrect but Firmware says key was created. SCGCQ00570040 - On a controller with Local Key Management(LKM) enabled, user is asked to enter the security key to unlock and import a foreign, locked and External Key Management(EKM) enabled drive. SCGCQ00571671 - After starting Patrol Read in the HII application, booting to OS and checking the status in MSM shows Patrol Read as suspended. SCGCQ00574396 - Getting Question Value mismatch when entering Controller management screen SCGCQ00602011 - MR to iMR downgrade error SCGCQ00605773 - Pinned cache gets flushed to incorrect VD for mirrored RAID levels SCGCQ00619188 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap. SCGCQ00630411 - Cannot create pinned cache during an Online Controller Reset (OCR) SCGCQ00556744 - Switching the security mode from External Key Management(EKM) to Local Key Management(LKM) on iMR controller will result in a corrupted controller key. SCGCQ00571420 - Getting a non informative message when trying to import a Virtual Drive after a re-key without reboot SCGCQ00626852 - Internal Development team defect to check-in gemini image to resolve SSD drives missing issue. SCGCQ00530838 - Unable to suspend the Patrol Read operation in iMR mode from the HII application SCGCQ00530857 - Bad battery warning message that comes up during POST isn't aligned properly. SCGCQ00553023 - HDD status LED will be lit red after creating and deleting LD but the status is normal via MSM SCGCQ00579157 - Firmware break into montask, when there is a pinned cache( During bootup and OCR ) SCGCQ00601452 - Controller breaks into montask if you have 10 enclosures connected to the controller. SCGCQ00600478 - VD erase does not resume and complete after reboot. SCGCQ00556740 - A data TLB error occurs when the External Key Management Server(EKMS) is down and drive security is changed from External Key Management(EKM) mode to Local Key Management(LKM) mode. SCGCQ00579672 - Remove redundant code within a particular function SCGCQ00604555 - Storecli reporting incorrect values for tfm and supercap date of manufacture SCGCQ00575142 - Static analysis tool defects SCGCQ00596556 - Unable to discard pinned cache in Headless Safe Mode. SCGCQ00496086 - Enhance code to catch Stack Overflow problem as soon as it occurs. SCGCQ00554056 - Write buffer flash programming support SCGCQ00552197 - Implement I2C Slave Address for Sideband Management SCGCQ00604565 - Add Fastpath Support by Default for a particular OEM. SCGCQ00496648 - When pinned cache present VD property not changing from WB to WT. SCGCQ00496649 - PDs go online without VD created & App doesn't allow any VD creation on passing a wrong parameter in Spanned VD. SCGCQ00504674 - Booting a 12G server into a degraded Raid 5 array will result in limited functionality SCGCQ00504683 - Improve Boot time that was lengthened due to previous change. SCGCQ00556161 - (DDR3) CKE and Reset clamping circuit can cause DDR errors at initialization time SCGCQ00557763 - Incorrect variable type in MR Read/Modify/Write path SCGCQ00570105 - Gemini image updated SCGCQ00580318 - Raid configuration loss after reboot - PDs in POWERSAVE SCGCQ00603255 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset SCGCQ00603258 - OEM MR TB controller reports foreign configuration on adapter during a 100 AC power cycles SCGCQ00626839 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap. SCGCQ00477016 - FW sending wrong configuration data during boot msg pending state SCGCQ00498129 - I/O's fail and VD becomes failed during planned failover of owner node w/ SMB I/O SCGCQ00501146 - Configuration import of GHS (Global Host spare) fails. SCGCQ00502949 - Firmware hits Montask when drive is pulled after changing the volume property from read ahead to no read ahead. SCGCQ00522634 - VPD output of lspci vvxxx showing [RV] Reserved: checksum bad, 86 byte(s) reserved SCGCQ00555284 - Gemini image updated SCGCQ00556756 - disableBatteryWarning should not be reset if changed by user SCGCQ00600687 - An invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive SCGCQ00601379 - Fix for Infinite retries of command for sense code 0B/47/03 SCGCQ00613782 - Liberator Card loses its boot VD after many reboots SCGCQ00479699 - Upgrading from Software RAID to 9260-8i causes Alarm to sound SCGCQ00552759 - Incorrect variable type in MR Read/Modify/Write path SCGCQ00557614 - Bad or Missing TMM boot message is changed to Critical error SCGCQ00571404 - In case of a certain OEM iMR shows R5 enabled. SCGCQ00575043 - Running out of free entries in task list due to recursive addition of tasks SCGCQ00601892 - Fix for Infinite retries of command for sense code 0B/47/03 SCGCQ00606336 - RAID configured on PD been erased with Normal or Thorough will lost after system reboot/reset SCGCQ00609531 - Kill adapter is seen while performing CME recovery during Write operation. SCGCQ00609535 - CME logic using overlaid fields in c->rec SCGCQ00573950 - system black screen during S1 Sleep test SCGCQ00574335 - Operating System event log reports a controller error during stress testing SCGCQ00579738 - With Headless Continue On Error Mode(HCOE) enabled and the SafeStore BIOS password enabled, if the wrong password is entered you are stuck at the same screen . SCGCQ00600686 - An invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive SCGCQ00613783 - Liberator Card loses its boot VD after many reboots SCGCQ00502952 - Code Review: Call DDF_discardInvalidPds only if DS3 is enabled SCGCQ00504687 - FW take a long time to boot to OS SCGCQ00546684 - Cluster validation failed in disk arbitration SCGCQ00558263 - HDD status LED will be lit red after creating and deleting LD but the status is normal via MSM SCGCQ00570170 - Deep learn will not start immediately when Relative State of Charge (RSOC) of battery is equal to 95%. SCGCQ00570251 - Patrolread will not start on any VD after a PR is started, suspended and VD is deleted SCGCQ00575155 - VD goes offline when we start reconstruction on 32 Drive R0 VD SCGCQ00579225 - Clear up stale cache lines. SCGCQ00603257 - OEM MR TB controller reports foreign configuration on adapter during a 100 AC power cycles SCGCQ00609530 - MR 6.3: md5sum mismatch seen on a copied file from R5 VD with CME SCGCQ00570171 - Deep learn will not start immediately when Relative State of Charge (RSOC) of battery is equal to 95%. SCGCQ00556757 - search for one wire devices prints are masked after the boot BIOS - 5.46.02.0 SCGCQ00579962 - Initialize deviceExposure with MAX_INT13DISKS instead of 0xFF SCGCQ00572939 - Make sure all the make file adheres to the latest binary names. SCGCQ00559095 - Provide an option to limit the max number of INT 13h devices presented to system BIOS Hii - 03.07.11.00 SCGCQ00579816 - HII\EKM-LKM without reboot should show proper message SCGCQ00594011 - With out selecting any drives I am seeing the previous config VD size. SCGCQ00609737 - Confiuration Restore is not working SCGCQ00618674 - StartHiiImpl() WriteToLogger uses %g and EFIHiiDriverEntryPoint() Print statement uses %g for displaying EFI status SCGCQ00521488 - Getting error message when we suspend Patrol read operation through HII browser SCGCQ00565876 - Remove duplicated strings from the UNI FIle SCGCQ00571353 - Allow user to select RAID level when controller has other VD + error handling SCGCQ00573871 - fixing code review defects (AIM version + UCM GUID + deallocation) SCGCQ00614027 - Firmware updation fails SCGCQ00615221 - Form UF003 prints error messages (use WriteToLogger to log these debug messages) SCGCQ00617617 - FWMgmt Prtocol: has no "versionid" info. SCGCQ00565088 - Help content for Firmware Update in Controller Management is inappropriate SCGCQ00569098 - Enter security key for locked drives screen, press down to get to OK, OK will show up again on right SCGCQ00598822 - VD details display is improper in Expand Virtual Drive SCGCQ00613822 - Advanced Controller Properties- Power Saving Settings has broken form SCGCQ00556839 - Able to select EKM even when the EKM FOD key is removed from the system. SCGCQ00589301 - System/HII hang when clicks on Hardware Components menu option in HII. SCGCQ00595864 - On Success of creating Drive Security Form loads into Advanced controller properties SCGCQ00598431 - Drop Down option in VD properties for Cached is present SCGCQ00610889 - Customize help string for Select Interface Type SCGCQ00615190 - ill Controller Index in RouteConfig + for UF003 calculate checksume only for the actual config size SCGCQ00593558 - Auto Learn Mode is showing wrong data SCGCQ00612574 - Addressed review comments SCGCQ00613820 - Typo in HII form Controller Status SCGCQ00622464 - Toggling bewtween Legacy to Uefi mode vice versa junk values seen . SCGCQ00524969 - HII PKG 0006/Going from LKM to EKM asks for a Current Security key Identifier and Security key. SCGCQ00590465 - n selecting a wrong parameter for size while creating VDs, Options greyed, Create VD page exits to parent page. SCGCQ00595463 - Security feature is enabled but HII sees "Drive Security" as disabled SCGCQ00571359 - Typo "Clear Configuaration" -> "Clear Configuration" SCGCQ00573222 - Handling Code Collaborator Review Defects for SCGCQ00568814 and SCGCQ00569197 SCGCQ00575062 - added a while loop and take care of the multiple PD Groups scenario. SCGCQ00578190 - HII should calculate checksum before setting bios data SCGCQ00597641 - MR6.3 HII aesthetic change SCGCQ00503036 - Changing Percentage of Space to Expand Does not Update Final VD Size SCGCQ00574041 - AIM (Agentless Inventory Manager) Issues SCGCQ00574989 - Creation+ FW updation+ Scan foreign Configuration is disabled/grayed out in HII page SCGCQ00614466 - Under advanced controller properties and selecting Cache and Memory, it says's "scontroller cache" SCGCQ00614675 - To address FW Update help Strings SCGCQ00619028 - Not able to schedule CC in concurrent mode from HII(03.07.09.00). SCGCQ00526978 - HII. Provide controller FW update function SCGCQ00568814 - HEFU. Simplify controller propety page SCGCQ00568706 - Remove limitation for creating R6 in HII SCGCQ00612466 - Provide pop-up to display current version and update fw version as part of HEFU HII Firmware Update functionality SCGCQ00571579 - Create a formset with classGUID that customer has provided. SCGCQ00569197 - Move Disable Protection option from Controller Management to VD management SCGCQ00601110 - Able to select EKM even when the EKM FOD key is removed from the system. SCGCQ00557522 - System hang observed when the "PdInfo.userDataBlockSize" is set to 0 SCGCQ00601119 - HII help for Boot error handling does not display "Stop On Error" option SCGCQ00601107 - HII PKG 0006/Going from LKM to EKM asks for a Current Security key Identifier and Security key. SCGCQ00601103 - Enter security key for locked drives screen, press down to get to OK, OK will show up again on right SCGCQ00601113 - HII\EKM-LKM without reboot should show proper message SCGCQ00601117 - UCM Phase 1: Allow user to select RAID level when controller has other VD + error handling SCGCQ00572986 - System hang observed when the "PdInfo.userDataBlockSize" is set to 0 SCGCQ00603235 - HII help window shows unsupported stripe sizes SCGCQ00596920 - Missing BBU caused disappearance of Enclosure Mgmt opt in BIOS setup SCGCQ00601120 - In HII on a ready drive we are able to see Used space as 40Gb. SCGCQ00601118 - Typo "Clear Configuaration" -> "Clear Configuration" SCGCQ00601116 - added a while loop and take care of the multiple PD Groups scenario. FCODE - 4.16.08.00 UEFI_Driver - 0x06060900 SCGCQ00618669 - UEFI Driver: StartHiiBackEnd() has Print statement with %g SCGCQ00578194 - UEFI Driver should calculate checksum before setting bios data SCGCQ00601851 - System hang when we press F1 on second time when we are in HII form SCGCQ00628627 - UEFI Driver- has debug print statements during POST SCGCQ00589148 - Diskpart EFI utility can't create partition on a JBOD SCGCQ00526851 - Support EFI_FIRMWARE_MANAGEMENT_PROTOCOL for controller firmware SCGCQ00579837 - UEFI Driver should calculate checksum before setting bios data SCGCQ00606367 - UEFI Driver returns EFI_NOT_FOUND when platform passes valid SCGCQ00580313 - User can't access RAID HII in UEFI mode after removing a HDD WebBIOS - 6.1-71-e_71-Rel NVDATA - 2.1403.03-0128 SCGCQ00563766 - Added support for subOEM 8 version of Alcor-S 9271 Controller PCLI - 05.07.00 BootBlock - 2.05.00.00-0010 BootBlockCommon - 07.26.26.219 ROMENV - 1.08 23.22.0-0020 (MR5.9 patch3) Firmware - 3.340.55-3173 SCGCQ00619188 - Cache policy of Virtual Drives(VD) does not change to Write Through(WT) mode even after detecting a bad supercap. BIOS - 5.45.07.0 Hii - 03.05.11.03 FCODE - 4.16.08.00 UEFI_Driver - 0x06030501 WebBIOS - 6.1-71-e_71-Rel NVDATA - 2.1312.03-0124 PCLI - 05.07.00 BootBlock - 2.05.00.00-0010 BootBlockCommon - 07.26.26.219 ROMENV - 1.08 23.22.0-0017 (MR5.9 patch2) Firmware - 3.340.35-3075 SCGCQ00552222 - Raid configuration loss after reboot - PDs in POWERSAVE SCGCQ00531244 - Display the NCQ enabled/disabled status of every SATA disk drive in the output of StorCLI and MegaCLI SCGCQ00557763 - Incorrect variable type in MR Read/Modify/Write path SCGCQ00570105 - Gemini image updated - SCGCQ00603258 - OEM MR TB controller reports foreign configuration on adapter during a 100 AC power cycles SCGCQ00600686 - An invalid frame sent during a PIO-mode SATA passthrough command results in resetting the drive SCGCQ00601379 - Fix for Infinite retries of command for sense code 0B/47/03 SCGCQ00570170 - Deep learn will not start immediately when Relative State of Charge (RSOC) of battery is equal to 95% BIOS - 5.45.07.0 Hii - 03.05.11.03 FCODE - 4.16.08.00 SCGCQ00553069 - PCLI(1.07.05) Sparc: Command "cli set securitykey=xxxxxxx" fails with errcd "1001" and errmsg "invalid key". UEFI_Driver - 0x06030501 WebBIOS - 6.1-71-e_71-Rel NVDATA - 2.1312.03-0124 PCLI - 05.07.00 BootBlock - 2.05.00.00-0010 BootBlockCommon - 07.26.26.219 ROMENV - 1.08 23.22.0-0012 (MR 5.9) **NOTE: Full native 4K sector Firmware support is provided in firmware since MR 5.8 release Firmware 3.340.05-2939 SCGCQ00358434 - StorCLI: Showing success for assigning a secured VD to cachepool whereas the operation is failure. SCGCQ00441316 - Supercap is not detected but cache offload and restore happens SCGCQ00476320 - Faulty protocol used for changing the Disk Write Cache Policy SCGCQ00504475 - Unable to create another Virtual Drive when pulling first drive (degrading) in partial Virtual Drive where all drives are configured SCGCQ00518693 - Active/suspended patrol reads not terminated during VD deletion SCGCQ00522321 - Error message displayed after suspending a Patrol Read Operation using the HII application SCGCQ00522381 - Incorrect information is returned for SATA drive when the drive is connected behind the interposer. SCGCQ00473201 - Firmware montask when solaris is installed on 4 drive Raid6 with 2 drive failure SCGCQ00552847 - Data Integrity issue found with CacheCade when CacheCade disassociation is initiated after running IO SCGCQ00487288 - The Firmware does not change the Virtual Drives's from Write Through to Write Back after a battery manual learn cycle is complete SCGCQ00501286 - Baseboard Management Controller (BMC): STP passthru command failure SCGCQ00500984 - HII - Last physical drive in 84 physical drive enclosure is displayed 4 times SCGCQ00501630 - Drive security mode switching in MSM SCGCQ00476528 - When I/Os are running on SATA Physical Drives with interposers, a drive removal and reinsertion within drive-removal-delay comes back as failed. SCGCQ00484803 - The Firmware does not change the Virtual Drives's from Write Through to Write Back after a battery manual learn cycle is complete SCGCQ00552110 - Gemini image updated SCGCQ00333207 - Request to support 128 drives within single enclosure SCGCQ00466994 - Added support in FW to import CC1.x VDs. SCGCQ00467207 - Support Revision 17 and Revision 18 Supercaps SCGCQ00501863 - Clustered Media Error handling does not work for read operations during RAID-5 writes SCGCQ00479734 - When Cachecade LD is deletec invalid LD details is shown in the Cachecade size changed event. SCGCQ00487279 - MR Controller does OCR due to Temp Buffer overflow SCGCQ00498098 - 9240-4i on BCM RX67Q-6S motherboard is not getting required memory resources on boot SCGCQ00479736 - D_SENSE bit in Mode Select Page=0a is set for < 2TB disk SCGCQ00479732 - T-bolt MR (PL) FW : Invalid "mode select(Page=0a)" issued during disk initialization phase. SCGCQ00479499 - iMR TB Data loss when reconstructing from 1 drive R0 to 2 drive R1 with reboot SCGCQ00480237 - For iMR, Firmware is faulting when trying to flash firmware after Online Control Reset. SCGCQ00501862 - Clustered Media Error handling does not work for read operations during RAID-5 writes SCGCQ00481029 - Storcli: wrong error code displayed and wrong error message for copyback command SCGCQ00557108 - Data Integrity issue found with CacheCade when CacheCade disassociation is initiated after running IO SCGCQ00470407 - Remove support of a certain TMM-B from currently released firmware SCGCQ00504011 - Cache offload is started when server's power down (DC Off) on WebBIOS or Post phase. SCGCQ00505203 - Validate the requested blocks for SCSI VERIFY commands on RAID volumes SCGCQ00484048 - Faulty protocol used for changing the Disk Write Cache Policy SCGCQ00471478 - Firmware crash seen while doing continuous sas cable pull SCGCQ00467493 - Foreign config import is getting failed when using multiple enclosures SCGCQ00505732 - Firmware montask when solaris is installed on 4 drive Raid6 with 2 drive failure SCGCQ00490891 - Firmware Crash during Controller StartUp when large number of drives are connected SCGCQ00480242 - For iMR, Firmware is faulting when trying to flash firmware after Online Control Reset. SCGCQ00493102 - Can't import foreign configuration on degraded arrays after system reboot SCGCQ00480234 - A single supercap pack should not be supported on a 2GB memory module SCGCQ00501103 - Validate the requested blocks for SCSI VERIFY commands on RAID volumes SCGCQ00485583 - For a particular OEM fault LED does not come on when a bad HDD is inserted SCGCQ00479709 - Firmware returns asc value as 0 when failing IOs with medium errors SCGCQ00471470 - Firmware crash seen while doing continuous sas cable pull SCGCQ00493101 - Can't import foreign configuration on degraded arrays after system reboot SCGCQ00479731 - Foreign config import is getting failed when using multiple enclosures SCGCQ00472867 - Defect Fix for Excessive unexpected sense events reported on PI enabled R5 VDs SCGCQ00479737 - Installing and uninstalling iMR FOD key overwrites MR controller features SCGCQ00472864 - Defect Fix for Excessive unexpected sense events reported on PI enabled R5 VDs SCGCQ00479502 - iMR TB Data loss when reconstructing from 1 drive R0 to 2 drive R1 with reboot SCGCQ00479721 - Intermittent SEP errors on iMR and MR controllers SCGCQ00487278 - MR Controller does OCR due to Temp Buffer overflow WebBIOS 6.1-71-e_71-Rel SCGCQ00333215 - Request to support 128 drives wihin single enclosure SCGCQ00488500 - Added support for OEM controller whose PCI subsystem Id is 2208 SCGCQ00488501 - Added support for OEM controller whose PCI subsystem Id is 2240 SCGCQ00488502 - Added support for OEM controller whose PCI subsystem Id is 0001 NVDATA 2.1312.03-0124 SCGCQ00493673 - StorCli does not list all the available BBU modes. BIOS 5.45.07.0 SCGCQ00479507 - FW 3.340.05-2739/Getting memory conflict during boot SCGCQ00495471 - OOB function corrupts EBDA area used by other server function SCGCQ00493680 - Optimize reading IO port in INT15h path SCGCQ00552308 - OEM system is not allocating memory correctly when MR and iMR are in the same system SCGCQ00482283 - iMR: System reboots during IO because FW didnt receive permanent host memory from OpROM SCGCQ00503046 - OpROM is displaying incorrect value for the number of INT13h device it supports SCGCQ00466276 - Check the controller status bit in the function which hooks INT15 SCGCQ00454086 - Add boundary checking when allocating EBDA and PMM memory for BIOS post. SCGCQ00460724 - Memory access issue when loading Ctrl R SCGCQ00460725 - Memory allocation: Allocate only two 64k PCLI 05.07.00 SCGCQ00472311 - (CBB) Provide mechanism to disable PCIe backchannel training via SBR UEFI_Driver 0x06030500 SCGCQ00479003 - Disable Debug print in UEFI Driver SCGCQ00435384 - UEFI System hang if controller FW is in fault state SCGCQ00498925 - Not able to boot into BIOS boot menu SCGCQ00493654 - Memory Leak issue in UEFI driver when reconnect happens SCGCQ00518791 - DriverDiagnostics2.c: In IsValidHandle() - Free the buffer if status is not EFI success for LocateHandle SCGCQ00483847 - EKMS: Remove private GUID and use EFI_KMS_PROTOCOL_GUID defined in UEFI 2.3.1 spec SCGCQ00484086 - hang when SATA is connected SCGCQ00468948 - Uninstall HII CAP and Driver Health formset if platform calls Start again without calling GetHealthStatus SCGCQ00477828 - 9240/9260/9270 UEFI driver issue when user having 2TB or 4TB VD SCGCQ00478692 - Block IO tests from SCT IHV test suite failed SCGCQ00484114 - Follow UEFI Spec on interpreting In and Out Transfer Length that upper layer sends Hii 03.05.11.00 SCGCQ00470101 - Allow user to edit VD size (that is free form input) as it is cumbersome to modify the size using +/- SCGCQ00471830 - Save and Restore Configuration SCGCQ00556209 - Transition a MR controller to run in iMR mode = Controller fail in HII After Memory removed SCGCQ00556811 - HII - When controller is in safe mode the PD menu displays inaccurate text and hangs when clicking a PD SCGCQ00529287 - Profile Based Raid1 Creation fails as invalid arguments SCGCQ00502940 - Naming inconsistency in option present in Create VD and Create VD - Advanced SCGCQ00482092 - HEFU_HII: condition checking is not right SCGCQ00474402 - HII: Allows user to select EKM mode when supportEKM is set to 0 SCGCQ00485401 - 5.9 PKG 0002 HII/Using 84 PD encl when clicking on HW, Advanced then Enclosure Management, it completly freezes the system SCGCQ00473204 - MR UCM 2.0: unable to show UF003 as well the first two forms + XML special character handling SCGCQ00486457 - HEFU_HII_MR6.2: fixing memory leak of 128 drive enclosure implementation SCGCQ00505566 - MR 6.2-HII: Drop down option to set phy linkspeed tp 12 Gbps in HII browser is not available. SCGCQ00473186 - Save and Restore Configuration - MR w/ Premium Features (SED and Cachecade) SCGCQ00501111 - HII 3.05.07.00/Issues when trying to change EKM security key from change security key option. SCGCQ00523869 - EKMS\HII PKG 0006\EKMS is down but it is still possible to select drive security in MSM and HII during creation. SCGCQ00527700 - Update the latest API change in HEFU SCGCQ00500945 - MR: EXPAND operation fails in HII for prl11 SCGCQ00494431 - Streamline the usage of max PD in limited configuration path (alias UCM) SCGCQ00494214 - Help content for Free space in Select Drive group is inappropriate SCGCQ00485932 - UCM Simple Configuration: Allow Clear Config always + Suppress Checkbox (Uf002.PDs) when VD count is >0 SCGCQ00472196 - Profile based VD creation path incorrectly showing protect VD/secure VD checkbox when user clicks on drive selection criteria SCGCQ00481284 - Typos in help content for profile VD for Write Policy SCGCQ00471209 - UCM Phase2: config using 8PDs/16 partial VDs and all stripe sizes and HSPs does not restore SCGCQ00487936 - UCM-After creating a VD with UCM tool the manual configuration PD section still shows configured PDs as UG, and duplicates SCGCQ00495236 - Controller not seen in HII Browsercan after switiching from EFI WebBIOS SCGCQ00505591 - Checking the Enclosure Management settings in HII causes the system to reboot. SCGCQ00475217 - Request to support 128 drives wihin single enclosure SCGCQ00468930 - UCM Phase 2 support SCGCQ00481277 - Request to change the help content for write policy in create VD form SCGCQ00415456 - Obtain the Physical Slot number from the PCI Bridge to which the Controller is connected. SCGCQ00476607 - HII cannot assign partial space less than 1 GB SCGCQ00498521 - MR 6.01 : HII cannot create a VD using unconfigured good drives as long as PD locate is set on the drives FCODE 4.16.07.00 SCGCQ00471703 - Fcode CLI support for Invader (MR only) SCGCQ00486355 - Define and use capability bit to identify the StorCLI BootBlock 2.05.00.00-0010 BootBlockCommon 07.26.26.219 ROMENV 1.08 23.18.0-0014 (MR5.8 patch1) MR Firmware - 3.290.15-2935 SCGCQ00552847 - Data Integrity issue found with CacheCade when CacheCade disassociation is initiated after running IO SCGCQ00484803 - The Firmware does not change the Virtual Drives's from Write Through to Write Back after a battery manual learn cycle is complete SCGCQ00449662 - Foreign config import is getting failed when using multiple enclosures SCGCQ00457913 - Defect Fix for Excessive unexpected sense events reported on PI enabled R5 VDs SCGCQ00459680 - iMR TB Data loss when reconstructing from 1 drive R0 to 2 drive R1 with reboot SCGCQ00470499 - For iMR, Firmware is faulting when trying to flash firmware after Online Control Reset.] SCGCQ00477801 - MR Controller does OCR due to Temp Buffer overflow SCGCQ00481595 - Can't import foreign configuration on degraded arrays after system reboot SCGCQ00449115 - Clustered Media Error handling does not work for read operations during RAID-5 writes SCGCQ00473201 - Firmware montask when solaris is installed on 4 drive Raid6 with 2 drive failure SCGCQ00552110 - Gemini image updated SCGCQ00467625 - Validate the requested blocks for SCSI VERIFY commands on RAID volumes BIOS - 5.42.00 Hii - 03.03.07.00 UEFI_Driver - 0x06010300 FCODE - 4.14.05.00 WebBIOS - 6.1-68-e_68-Rel NVDATA - MR2.1310.03-0122 PCLI - 05.07.00 Ctrl-R - 4.02-0001 BootBlock - 2.05.00.00-0010 BootBlockCommon - 07.26.13.219 ROMENV - 1.08 23.18.0-0013 (MR5.8) MR Firmware - 3.290.05-2720 **NOTE: Full native 4K sector Firmware support is provided in this release SCGCQ00462339 - Virtual Drive creation failure in iMR during pre-boot SCGCQ00454816 - Recon VD made "degraded" when the recon pd is pulled out allowing for rebuild once the drive is plugged back in. SCGCQ00448786 - static variable used in PD Progress and LD Progress function which may affect multiple progresses running at the same time. SCGCQ00437008 - MegaRAID controller does not display a boot message when it has entered safe mode. SCGCQ00435944 - Allow adding a lba when table entries are exhausted, but addition is possible if consecutive to existing entry SCGCQ00434388 - When pulling and pushing SSD SATA PDs under 5 seconds, the SSDs come back as failed after a minute or so. SCGCQ00420777 - Fw defect in PdStateSet() SCGCQ00419399 - Hard coded values should be removed in TFM module SCGCQ00414056 - Potential IO integrity with R0/R1 CIO WT when overlapping R/W issued to LD. SCGCQ00413472 - Unable to perform Consistency Check and other background operations in a legacy WebBIOS SCGCQ00413254 - Multiple VDs undergoing full init show a calculated estimated time remaining even though they sit at 0% SCGCQ00406688 - Static Code Analysis Tool warnings: IDs - 10007 , 10338 , 10340, 10356, 10364 , 10371, 10389, 10390, 10847, 10848 SCGCQ00406301 - Static Code Analysis Tool warnings 10071, 10100, 10162, 10174, 10288, 10332, 10361, 10363, 10503 SCGCQ00406219 - FW reports "Progress init not proper" during 16 VD Rebuild SCGCQ00400809 - Data miscompare seen when errors injected to a RAID6 virtual drive SCGCQ00400807 - Potential data integrity issue During Check Consistency On 4DG R6 arrays with 16 VDs per array SCGCQ00400564 - Delete VD while PR still in progress cause debugger to loop. Reboot the system, debugger still loops SCGCQ00393749 - MonTask: line 281 in file ../../raid/mem.c if running megacli AdpDiag SCGCQ00349837 - Sequential Read performance is less on CacheCade associated LD's. SCGCQ00451137 - If a BOOT Passphrase is enabled with SafeStor "MegaCli adpbios dsply a0" will display "BIOS will Stop on error" even if any other mode is set. SCGCQ00447927 - Message release issue in immediate IO path SCGCQ00446623 - Firmware crash during foreign config import SCGCQ00441299 - Updated line of code recommended in code review. SCGCQ00439477 - Verify drive reinsertion within/before drive-removal-delay setting -verify discovery (Without IO) SCGCQ00425796 - HII - Profile based VD creation - [Partial RAID options blocked until system reboot] SCGCQ00424928 - Application could not make a JBOD bootable without a VD present SCGCQ00423182 - bootMsgPending.needsEKM bit is not set when FW needs a key SCGCQ00422760 - Indifference between MR.H and FW implementation for lockKeyLength SCGCQ00420918 - Potential data integrity issue with a 4K RAID5 virtual drive SCGCQ00412766 - HII /When user has a critical message and the conrtoller is in Safe Mode, going into CTRL mang will result an error msg SCGCQ00404263 - Staggered CMEs across R10 array are causing a read error SCGCQ00475140 - Learn cycle will not start on supercap SCGCQ00451213 - Assertion failure in raid 1078main.c at line 993 during hibernation when IOs or background operations are running SCGCQ00448750 - UEFI-4K drives: Unable to create any virtual drives of strip size 256k-1MB with the 4K sector drives. SCGCQ00439050 - Static Code Analysis defects - 5.8 SCGCQ00436460 - Event is blocked during Full initialization SCGCQ00422757 - iMR firmware does not progress background operations with certain systems when using WebBIOS in legacy mode SCGCQ00420702 - Fw defects related to Disk Write Cache Policy settings SCGCQ00406148 - Grammatical spacing error in bios message at POST SCGCQ00400555 - The elapsed time shown in the FW debugger for a reconstruction not starting at 0 SCGCQ00399591 - 23.16.0.0005/Creating CacheCade with non supported OEM SSD using older FW and then flashing to 5.7 it's till available SCGCQ00398281 - "Question value mismatch with Option Value" message in HII's Controller Management when in Safe Mode with pin cache SCGCQ00393347 - Static Code Analysis Tool code changes SCGCQ00448628 - Rebuild failed event is not seen when rebuild fails due to LDBBM and SBBM tables getting full (puncturing disabled) SCGCQ00439947 - Static analysis tool defects SCGCQ00437731 - Remove memory module on MR controller to downgrade to iMR does not work SCGCQ00415473 - Fix code review defect D16582 in 5.8 stream for Review #17785: NCQ support is disabled in FW SCGCQ00400149 - Firmware failed to import drives to start rebuild after remove then reinsert SCGCQ00462008 - LDBBM_EXT table does not get read during init SCGCQ00443920 - Static analysis tool defects SCGCQ00440224 - Corrected defects found by static analysis tool. SCGCQ00439068 - Static analysis tool defect fixes SCGCQ00404301 - Significant drop in Sequenial read performance with Read Ahead policy SCGCQ00449597 - Multi-stripe size in each raid level of R1,r5,r6 with SAS, DIF, 4K pinned cache offline vd import cause Montask SCGCQ00446657 - Static Code Analysis Tool - Defect Code Changes SCGCQ00443455 - Static Analysis Defects SCGCQ00424293 - Setting the ASO key with storcli 1.02.08 (MegaCli 8.07.06) fails with an error code 3 on Windows or Linux if the MB BIOS PCI SCGCQ00406233 - Data Miscompare found while running I/O overnight with degraded virtual drives SCGCQ00443883 - Static code analysis tool fixes SCGCQ00436287 - HII critical message form/Extra character "r" with configuration not supported critical message. SCGCQ00399227 - Prevent overtemp warnings while battery is charging SCGCQ00411672 - CLI Reporting of TMM VPD SCGCQ00472756 - EKMS disabled in firmware by modifying support EKM property in a proper way. SCGCQ00399224 - Modify MR fw to eliminate four second window where drive swap is not recognized. SCGCQ00399233 - Rebuild automatically starts on drive with foreign configuration after reboot. SCGCQ00377263 - Modify sense data returned for an offline VD SCGCQ00399229 - Availability of information on PFK hardware keys presence/absence via termlog. SCGCQ00403115 - HA/Peer controller detection and handling logic SCGCQ00331562 - R5 rebuild fails source drive after LDBBM table is full SCGCQ00396289 - Defect fix for crash when fde disk connected SCGCQ00396296 - Ctrl+R BIOS hangs while hot plug of 2 enclosures with more than 32 drives on FURY controller SCGCQ00397338 - CC2.1_RA_Support : Data Integrity issue may happen upon creating WB CCVD during Cache Flush SCGCQ00397347 - Sequential Read performance is less on CacheCade associated LD's. SCGCQ00409501 - The reliability and error recovery of the SuperCap firmware was improved. SCGCQ00414020 - Adjusted the USB phy boost value for the OEM controllers SCGCQ00414463 - IO integrity error seen after Source VD associated with CacheCade VD is forcibly unblocked SCGCQ00414466 - During rebuild on PRL11 CacheCade VD and rebuild on RAID6 Source VD IO integrity error is seen. SCGCQ00417742 - BBU Charging gets disabled when Transparent Relearn fails to start due to low capacity SCGCQ00421945 - on iMR FW update caused card to FW fault state and card cannot boot to OS. SCGCQ00421967 - SEAGATE hotspare drives remain spun up on LSI FW 12.12.0-0079 SCGCQ00424028 - After COR (OCR) controller not longer available to HOST SCGCQ00426998 - Code Review defect to handle SA_INVALID_FIELD_IN_CDB SCGCQ00427028 - Change SES Green/Amber LED behavior for OEM JBOD enclosure. SCGCQ00427030 - Customer is hitting an ECC bug SCGCQ00427031 - Firmware returns invalid data in OOB packet SCGCQ00435303 - OEM facing with incorrect SAS HDD's indication, MSM shows 2X drives connected SCGCQ00435305 - Alarm continues to sound after copy-back is done, across reboot, from an unconfigured good drive that is used as an emergency spare. SCGCQ00436807 - Change RAID controller FW bad battery warning message that comes up during POST. SCGCQ00439490 - 9260 controller VD goes offline during Slow/Full/Foreground Initialize with 3TB Seagate SED SAS drives SCGCQ00442108 - 2208 ROMB see 0 Capacitance SCGCQ00462321 - Deep learn doesn't start when it is requested during relaxing. SCGCQ00340844 - Don't interpret the cachecade BVD flags if the volume is created with old FW which does not support cachecade. SCGCQ00357678 - immediate IO broken for R1 - (SCGCQ00357549) SCGCQ00384609 - Assertion failure in ../../raid/raidpci.c at line 10011 , while running IO with medium errors on arrays. SCGCQ00405889 - Auto Foreign import fails when controller is booted with pinned cache. SCGCQ00406635 - Power loop cycle test on a non DIF drive connected to LSI controller caused fatal firmware error SCGCQ00414469 - When a Cachecade PD marked as missing is reused to make Cachecade VD IO integrity error is observed. SCGCQ00418100 - If a correctable ECC error occurred during a cache offload, the CPU would crash, resulting in a data loss SCGCQ00418526 - montask hit at the line "Fatal firmware error: Line 1057 in ../../dm/src/dm.c while running copyback with 255 ME SCGCQ00424266 - Disable Band Gap feature for select customers SCGCQ00424272 - Disable Band Gap feature for select customers SCGCQ00426122 - Megamon issue when disabling the drive security on a MR controller with spun down FDE drives. SCGCQ00426172 - Copyback on a drive hits kill adapter SCGCQ00426433 - Setting the ASO key with storcli 1.02.08 (MegaCli 8.07.06) fails with an error code 3 on Windows or Linux if the MB BIOS PCI SCGCQ00426961 - immediate IO broken for R1 SCGCQ00427002 - disableHII: Needs to be updated from nvdata into MFCD SCGCQ00427591 - Infinite retry happens on Test Unit command when HDD didn't respond to TU command during the initialization. SCGCQ00432566 - Enable DS3 on TB code for OEM SCGCQ00450108 - TFM error handling : Cache policy change for WB to WT if supercap is faulty SCGCQ00455801 - OEM- StorCli should not allow turning on JBOD in MR mode SCGCQ00462305 - Deep Learn is not invoked in new battery, when the system is reboot before the first learn completes SCGCQ00462319 - Transparent Learn Cycle is rescheduled even though it is not completed SCGCQ00468434 - Write policy changed from WT to WB when the battery/Supercap is declared as bad SCGCQ00355900 - OCR observed after IO on reconstructed VD with ME's SCGCQ00381325 - Wrong event generated "Reminder: Potential non-optimal configuration due to drive PD xx(e0xfc/sx) commissioned.. SCGCQ00418110 - If the hotspare was spun down, the copyback after a drive failure wouldn't always start. SCGCQ00421950 - adapterOperations.alarmControl is being set to 1 even if controller doesnot have alarm on board SCGCQ00421964 - 9240-4i on one motherboard is not getting required memory resources on boot SCGCQ00421966 - Unable to open "Set Patrol Read Properties" in MSM with 2008-iMR SCGCQ00426092 - Megamon during Injecting errors to VD with 512e PDs on iMR controller SCGCQ00426194 - If VD is secured while reconstruction is going on does not stay secured once reconstruction is done. SCGCQ00427013 - Allocate BBLog for iMR Initally during boot up SCGCQ00427018 - When attempting to secure LD during RLM, receive option to secure LD, LD not secured (message incorrect/misleading.) SCGCQ00432842 - Saved Release Note DataSLIB returning bad data as good data after host reboots SCGCQ00436873 - Minimum Capacity needed for relearn is incorrect in 2208 MR FW SCGCQ00438483 - Improve foreign config import for iMR with mixed JBOD/RAID settings SCGCQ00446741 - Correct the error in copy back path smart errors path SCGCQ00456440 - Defect fix for VD rebuild doesnot kickin and goes to foreign state after reboot SCGCQ00464629 - Disconnect SCap during Shutdown/Hibernate only if pinned cache is not present SCGCQ00364724 - Assertion failure in ../../raid/raidpci.c at line 8323 while running IO with cable pull/push. SCGCQ00426204 - spare pointer is incorrectly used in MR_CONFIG_DATA SCGCQ00427032 - Fix For code analysis Defects Reported SCGCQ00432754 - Customer experiencing extremely long rebuild times under I/O with LSI 9288-8e Procyon-U) controller SCGCQ00436808 - Change RAID controller FW bad battery warning message that comes up during POST. SCGCQ00441823 - Patrol Read - no progress SCGCQ00450643 - 9260-8i(SAS2108) hitting OOB SRAT timeout for a long time causing OOB commands to fail SCGCQ00397250 - ECC/Medium/Unrecoverable read errors handling Enhancement SCGCQ00405886 - FW halts when you have pinned cahce and remove VD form the configuration. SCGCQ00418112 - If the hotspare was spun down, the copyback after a drive failure wouldn't always start. SCGCQ00421977 - Invalid target ID after new logical drive creation SCGCQ00427021 - sync error stat for MRS SCGCQ00427022 - megacli reports battery pack is missing on hot insertion SCGCQ00448174 - Card Running iMR Machine Checks when Requesting Host Memory SCGCQ00421953 - 9260-16i's drive locate/fault LED header doesn't work SCGCQ00427592 - Infinite retry happens on Test Unit command when HDD didn't respond to TU command during the initialization. SCGCQ00453504 - Defect Fix for Exception in Core 0 SCGCQ00456361 - Virtual drive configurations go missing during firmware upgrade from 5.3 to 5.7, while running Consistency Check (CC), after tworeboots SCGCQ00387315 - fix for the defect - 4k drives display wrong value of Coerced size. SCGCQ00454959 - Write policy changed from Write-through (WT) to Write-back (WB) when the battery/Supercap is declared as bad BIOS - 5.42.00 Hii - 03.03.07.00 SCGCQ00472196 - Profile based VD creation path incorrectly showing protect VD/secure VD checkbox when user clicks on drive selection criteria UEFI_Driver - 0x06010300 SCGCQ00435384 - UEFI System hang if controller FW is in fault state SCGCQ00392836 - Support Remote Key Management FCODE - 4.14.05.00 SCGCQ00418701 - Not possible to probe a volume > 2Tb on Niwot raid card WebBIOS - 6.1-68-e_68-Rel SCGCQ00414398 - In WebBIOS, if BGI is suspended the vd progress info page shows it as CC progress until it is resumed SCGCQ00471031 - Incompatible strip size convention in TB NVDATA - MR2.1310.03-0122 SCGCQ00419769 - Change in product name for OEM 2208 ROMB design SCGCQ00447780 - Added support for OEM controller SCGCQ00452126 - Updated OEM controller SCGCQ00459367 - Updated OEM controller PCLI - 05.07.00 Ctrl-R - 4.02-0001 BootBlock - 2.05.00.00-0010 BootBlockCommon - 07.26.13.219 ROMENV - 1.08 23.16.0-0018 (MR5.7p1) Firmware - 3.270.65-2578 - Virtual drive configurations go missing during firmware upgrade from 5.3 to 5.7, while running Consistency Check (CC), after two reboots - Card Running iMR Machine Checks when Requesting Host Memory Hii - 03.02.08.00 BIOS - 5.42.00 WebBIOS - 6.1-65-e_65-Rel PCLI - 05.07-00 NVDATA - 2.1304.03-0117 BootBlock - 2.05.00.00-0010 Common BootBlock - 07.26.13.219 23.16.0.0012 (MR 5.7) Firmware - 3.270.05-2430 Fixes **NOTE: Although several 4K sector changes are listed below, full native 4K sector support is defered to MR5.8 release. - Potential IO integrity with R0/R1 CIO WT when overlapping R/W issued to LD. - Unable to perform Consistency Check and other background operations in a legacy WebBIOS - Multiple VDs undergoing full init show a calculated estimated time remaining even though they sit at 0% - 'Static Code Analysis Tool' warnings: IDs - 10007 , 10338 , 10340, 10356, 10364 , 10371, 10389, 10390, 10847, 10848 - 'Static Code Analysis Tool' warnings 10071, 10100, 10162, 10174, 10288, 10332, 10361, 10363, 10503 - FW reports "Progress init not proper" during 16 VD Rebuild - Delete VD while PR still in progress cause debugger to loop. Reboot the system, debugger still loops - MonTask: line 281 in file ../../raid/mem.c if running megacli AdpDiag - Firmware crash during CME recovery - 5.7Static Code Analysis Tool changes - 'Static Code Analysis Tool' Defect OVERRUN STATIC: CIDs Out-of-bounds access - Code Analysis Tool fix - Sequential Read performance is less on CacheCade associated LD's. - Application could not make a JBOD bootable without a VD present - In HII, when user has a critical message and the conrtoller is in Safe Mode, going into CTRL Management will result an error msg - Significant drop in Sequenial read performance with Read Ahead policy - Staggered CMEs across R10 array are causing a read error - MR5.6 Beta Firmware BST: Code Analysis Tool Fix - Continues PR 2nd time on Raid 1 and then delete VD and reboot system cause debugger to continues loop and want to run PR - 5.7 FW PKG 23.11.0-0013/Using CLI, can change a cachecade PD to WB even though enableSSCWB=0 - Firmware does not progress background operations with certain systems when using WebBIOS in legacy mode - Grammatical spacing error in bios message at POST - The elapsed time shown in the FW debugger for a reconstruction not starting at 0 - "Question value mismatch with Option Value" message in HII's Controller Management when in Safe Mode with pin cache - Removed unwanted prints. For copyBack, total Blocks for copyback was not getting intitailized for right drive. Initialized for copyBack destination PD. Added necessary fix. - Code Analysis Tool Defect OVERRUN STATIC: CIDs Out-of-bounds access - Assertion failure fixed for issuing "adpdiag" from megacli-dos - Correct formatting and compilation issues - Firmware failed to import drives to start rebuild after remove then reinsert - Fixes for defects found by Static Code Analysis Tool - 'Static Code Analysis Tool' code changes - Firmware is sending totalElapsedSecs value as 0 for LD and PD progresses - MegaCli pdFwDownload fails on a SATA drive with an interposer (parent defect is SCGCQ00352210) - Timed critical boot message under UEFI mode not showing - Fix for Firmware asserted when VDs are offline - Code Analysis Tool Fix - Firmware blocked firmware download to interposer - NCQ support is disabled in FW - Double media error getting corrected during check consistency - Data Miscompare found while running I/O overnight with degraded virtual drives EnhancementRequests - 4K sector support - Cache Mgmt, Snapshot, LD config, RAID ** - CME handling improvements for handling multi-row I/Os - 4K sector support - Switch to enable/disable 4K feature, Restrict "Snapshot" to 512-sector drives ** - Firmware returns invalid data in OOB packet - ECC memory error boot message and event log enhancement. - Rebuild time reset - Provide Fastpath as a standard offering for TB based controllers - Ability to power off and on individual HDD - Port latency outlier fixes to FW (from legacy PR137246) - 4K sector support - DDF, DM, Host Interface ** - 4K sector support - iMR, analyze all remaining hard-coded instances of "512" ** - RRB 45 - CLI Reporting of TMM VPD CSETActivities - DDF rev is not updated properly when both 4K and 512 drives are present ** - MR2208 JBOD function can't handle the UNC error of SATA disk - MR Controller Rejects Vendor Unique SCSI Command - Double media error getting corrected during check consistency - Ctrl+R- Ctrl+R BIOS hangs while hot plug of 2 enclosures with more than 32 drives - [MR5.4] CacheCade: ECC/Medium/Unrecoverable read errors handling Enhancement - CC2.1_RA_Support : Data Integrity issue may happen upon creating WB CCVD during Cache Flush - Sequential Read performance is less on CacheCade associated LD's. - Adjusted the USB phy boost value for the OEM controllers with SubDevice IDs between 3510 and 3515. - IO integrity error seen after Source VD associated with CacheCade VD is forcibly unblocked - During rebuild on PRL11 CacheCade VD and rebuild on RAID6 Source VD IO integrity error is seen. - BBU Charging gets disabled when Transparent Relearn fails to start due to low capacity - SCSI Pass-Through to SAS SSD returns data but disk reported medium error - Foreign config import failed from MR to iMR on Solaris 11x86 - Assertion failure in ../../raid/raidpci.c at line 10011 , while running IO with medium errors on arrays. - reading SATA IDENT information using STP_Passthru doesn't work with latest FW - Continues PR 2nd time on Raid 1 and then delete VD and reboot system cause debugger to continues loop and want to run PR - Disk missing sporadically during reboot of OEM - Auto Foreign import fails when controller is booted with pinned cache. - Power loop cycle test on a non DIF drive connected to LSI controller caused fatal firmware error - Significant drop in Sequenial read performance with Read Ahead policy - When a Cachecade PD marked as missing is reused to make Cachecade VD IO integrity error is observed. - If the hotspare was spun down, the copyback after a drive failure wouldn't always start. - Wrong event generated "Reminder: Potential non-optimal configuration due to drive PD xx(e0xfc/sx) commissioned.. - "Assertion failure in ../../raid/mem.c at line 281" on issuing "adpdiag" from megacli-dos - TFM modules with dirty data can cause the controller to hang during boot when transported to another controller - The reliability and error recovery of the SuperCap firmware was improved. - If a correctable ECC error occurred during a cache offload, the CPU would crash, resulting in a data loss - VD becomes WT with a good & new Super Cap on boot - (multiple) Megacli64 error in deadlock state - Timed critical boot message under UEFI mode not showing - Firmware blocked firmware download to interposer - NCQ support is disabled in FW - Data Integrity issue may happen upon creating WB CCVD during Cache Flush - Adjusted the USB phy boost value for the OEM controllers with SubDevice IDs between 3510 and 3515. - GHS drives changed to unconfigured good after OCR / System reboot scenario's - BMC see clock stetching on I2C bus - MR Controller Rejects Vendor Unique SCSI Command - Copyback was successful when the block sizes did not match - [MR5.4] CacheCade: ECC/Medium/Unrecoverable read errors handling Enhancement - FW halts when you have pinned cache and remove VD form the configuration. - Defect fix for 4 K drives Foreign configuration import. - The reliability and error recovery of the SuperCap firmware was improved. - Timeout when creating a hotspare - reading SATA IDENT information using STP_Passthru doesn't work with latest FW - Disk missing sporadically during reboot of OEM - MR: VD created in IR controller comes as UG when connected. - Defect fix for 4K configuration record updation is not happening with 4k drives ** - Firmware asserted at raid/cache.c at line 3661 when VDs are offline - (multiple) Megacli64 error in deadlock state WebBIOS - 6.1-65-e_65-Rel - In EFI WebBIOS with CC running on a R1 when 1 PD is removed EFI WebBIOS still shows that CC is in progress - Controller breaks into Megamon when clicking on the enclosure link in WebBIOS NVDATA - MR2.1304.03-0117 - Degraded performance comparison With the latest MR 5.3 -MR_3.190.25.1887 Hii - 03.02.08.00 - HII doesn not allow user to use the remain free capacity to configure additional VD for R50/R10. - MR 6.1 HII: empty warning prompt is given when creating a CacheCade VD with forced writeback option BIOS - 5.42.00 WebBIOS - 6.1-65-e_65-Rel PCLI - 05.07-00 BootBlock - 2.05.00.00-0010 Common BootBlock - 07.26.13.219 Package 23.12.0-0013 Firmware - 3.240.25-2382 - Coverity issues fix - Sequential Read performance is less on CacheCade associated LD's. - Firmware returns invalid data in OOB packet - Double media error getting corrected during check consistency - [MR5.4] CacheCade: ECC/Medium/Unrecoverable read errors handling Enhancement - Significant drop in Sequenial read performance with Read Ahead policy - The reliability and error recovery of the SuperCap firmware was improved. - Disk missing sporadically during reboot of Puma3 - Adjusted the USB phy boost value for the Mars controllers with SubDevice IDs between 3510 and 3515. - NCQ support is disabled in FW - Athena Rack BMC see clock stetching on I2C bus - Timeout in CIMC when creating a hotspare - CC2.1_RA_Support : Data Corruption upon creating WB CCVD during Cache Flush - reading SATA IDENT information using STP_Passthru doesn't work with latest - Firmware blocked firmware download to interposer BIOS - 5.42.00 - Extremely long delay when the controller POST in Legacy mode - BIOS build date field is empty and build date is displayed as BIOS build time in SLT. - OpROM not getting relocated to runtime segment if the segment address is 0xC0000 - Handle BT750 when B0 and D1 controller is present in HAMR system - HAMR: BIOS to have a logic to filter CCVD and report Remote VD count at OpROM POST time - FW Version number Truncated by one digit in OpROM POST screen - BIOS: Provide scratch segment and populate info to assist Ctrl R to load latest host - Update PERC9 Sub System Device Ids and the corresponding BBS strings. - Retry read capacity if scsi status is not success - MR HWR OpROM BIOS : OOB (BMC) function corrupts EBDA area used by other server function Hii - 03.02.02.00 - HII hangs when trying to enter Configuration Management while in Safe Mode - HII message for Safe Mode is not clear - HEFU: Controller Status should reflect safe mode + dont log debug messages in serial port UEFI_Driver - 0x05270000 WebBIOS - 6.1-62-e_62-Rel - Wrong spanned drive group size is displayed by Web bios(Ctrl-H) PCLI - 05.07.00 FCODE - 4.12.05.00 NVDATA - MR2.1304.03-0118 - Added a subOEM 8 version of the AlcorTU 9273 controller and a subOEM 3 version of the Procyon 9290 controller - Degraded performance comparison With the latest MR 5.3 -MR_3.190.25.1887 between Phase -3 Gemini Vs Phase -1 Gemini BootBlock - 2.05.00.00-0010 Ctrl-R - 4.02-0001 BootBlockCommon - 07.26.13.219 ROMENV - 1.08 Package v23.11.0-0021 Firmware 3.230.05-2100 - Repeated power cycling the enclosure with interposers results in drives not detecting - While executing path-failover test with an SATA-SSD drive behind an interposer, the device is marked failed - Drive not Foreign when pulling drive from VD, reinserting, and changing to UG Hii 03.00.06.00 - HII Create Virtual Drive help file typo - HII displays Supercap capacity values in mAh instead of Joules like all other applications - MR, in HII the learn time shows as 8hours for catera flatwood controller UEFI Driver 0x05240000 BIOS 5.38.00 - MR HWR OpROM BIOS : OOB (BMC) function corrupts EBDA area used by other server function PCLI 05.07.00 - No controller properties for Online FW Update in MegaCLI Bootblock rel-2.05.00.00-0010 - SAS2208 FW MR 5.4 posting a "91" error code FW 23.9.0-015 WebBIOS 6.1-60-e_60-Rel - 5.5 FW 0003/1078 FW 11.0.1-0048\When 1078 controller has message the config is missing EFI webBIOS comes up blank - When creating a Global HSP, it is showing an SSD Drive group as being FDE - WebBIOS displaying wrong info for missing PDs when FDE drives are connected to controller NVData 2.1301.03-0115 MR_SAS_Ctrl-R 4.02-0001 Common BootBlock v07.26.13.219 v23.9.0-0018 - Drives dropped when flashing FW back from MR5.3 to 11M08 and FW crashes with TLB error - BGI does not correct ECC medium errors on 2nd arm of Raid 10 array - Cache offload would not work when a USB debugger was attached - Controller (Alcor-S with OEM PCI id's) is running into a Machine Check loop during copyback test. - Foreign config after reboot with some drives. - MR5.4 FW loses its time settings after OCR - SES device is not found during cable pull testing - Firmware assertion failure during power-cycle test - RAID Member disks state changed to (foreign) online and still can access. - SAS2208 ROMB LD Rebuild suspend/resume issue - MR HWR OpROM BIOS : OOB (BMC) function corrupts EBDA area used by other server function. - BIOS should check pMRCtrlInfo ->maxHANodes with > 1 to determine HAMR v23.9.0-0015 - MR FCODE Driver release - TB BIOS 5.37.00 - HEFU HII Release 2.05.00 for 2208 - Singed UEFI Driver 0x05180000 (for Win 8 Secure Boot) - MR 5.3 Bootblock rel-2.05.00.00-0009 - MR 5.4 NVData Release: MR Version 2.1209.03-0112; iMR Version 2.1209.04-0112 - MR_WebBIOS_MR5.4_2208_release_version_6.1-49-e_49-Rel - MR_SAS_Ctrl-R_MR5.4_2208_release_version_4.02-0001 - HWR_LSI_MR_5.4_PCLI_Release_Version_5.05.03 - Release 5.2: MegaRAID GCA Common BootBlock v07.26.13.219 - 11M06 TB ROMENV Release - Firmware does not backup data during power fail with SuperCap. -Serious performance issue found in the latest public official LSI 9285-8e MegaRAID firmware 1776(small sequential reads perf) -System failed to boot with enableJBOD feature with B0 board -HAMR: BIOS is firing LD list query with query type exposed to boot instead of cluster access -Applying changes in Automatic Learn Cycle Properties ends up with "Requested Command is invalid" -Help is missing for some of the fields. -OEM adapters card may training to PCIe Gen2 for certain slots -Bootblock is using NVRAM data even if NVRAM is uninitialized -Remaining capacity is coming 0 from FW. -Battery Firmware vesion(MR_BBU_DESIGN_INFO.moduleVersion) is coming as Null -WebBIOS does not warn user before importing PI enabled VD on PI disabled controller. -WebBIOS reports incorrect number of foreign configs during "Scan Devices" -Preboot apps have to change load address change because of FW changes -WebBIOS should not allow RLM for protected VDs with non-PI drives. -WebBIOS does not show "Day" for Next learn cycle time in battery page. And issue with safe mode. -WebBIOS displays SSD association screen for Secured and Protected VDs (Virtual drive table is empty). v23.7.0-0038 - R50 DIF VD with multiple rebuilds reports - ref mismatch - TB D1 controllers may train to PCIe Gen2 in certain systems v23.7.0-0037 - RAID features are lost because of errors while accesing TSOC using an old firmware (11M08) - Pulling cable when maintainpdfailhistory=1 create wrong state in arrays. - Memory test does not execute when performing FW diagnostics. - MFC variable enableSSCWB was not getting updated when updated via megaSCU - Dont log capacity change event post rebuild completion. - Log commission event only if Rebuild will start on the PD. - Clean up bad block list during background init/check consistency failure - SATA BBM list corruption - Stressing test on degrade raid with drives or rebuilding on drives will cause firmware hang v23.7.0-0033 - Option ROM hang on some systems with Quiet Boot enabled v23.7.0-0031 - Enabled support for SSD drive cache enable/disable - Clean up bad block list during background init/check consistency failure - SATA BBM list corruption - Stressing test on degrade raid with drives or rebuilding on drives will cause firmware hang - T-bolt firmware : makes unconfigured bad (foreign) to unconfigured bad on reboot. - cannot make the CacheCade configured PD as unconfigured bad even pulling it out during system online. - Hot Spare lost after FW update v23.7.0-0029 - Stressing test on degrade raid with UNC drives or rebuilding on UNC drives will cause firmware hang - Firmware reports device initialization completion status to be greater than 100% at startup - Split large bitmap reads into pieces - USB Cacheoffload restore fails after multiple power cycle. - When secure foreign drive is present, VD creation fails because FW become unresponsive - Check for the presence of PD before writing the data arms of a protected LD during BGI - FW asserts in CacheMemAllocForPrebootApps() when memory is allocated twice by BIOS. - USB Cacheoffload restore fails after multiple power cycle on a Madison controller - Querying SMART / PFA Status Returns All Zeros in Sense Data v23.5.0-0027 - Save repository information in NVRAM - MegaRAID FW could result in a deadlock condition when offloading data to USB cache module after a system power failure and a power restore condition before offload operation could be completed. - When windows are freed, re-initialize those fields because freed windows can be allocated to other commands in case of window crunch scenario. - iMR-f/w hang at Waiting for Expansion ROM to load. - Skip spare check for R0 cachecade vd. - Change protected R6 secure erase behavior - Remove faulty check - If LD is in offline state then dont initate flush. Delete the VD. - DATA TLB error seen during cache offload while performing automated system power cycling test with cache present. v23.4.1-0028 - FW_CacheCade_2.1_Integration - Hot Spare alarm sounding after 11M08 Phase 4 firmware update - FW hit MonTask: line 1221 in file ../../raid/1078dma.c when run I/O and create partition - MonTask: line 6613 in file ../../ssd/ssd_cache_fw.c during creation of SSCD. - while running IOs on VD using a cachecade WB VD FW goes to megamon - Data integrity while running I/O's on R0 VD with HSP kicking in for rebuild on R1 WB SSCVD v23.2.1-0033 - Reset disablebatterywarning in ctrl properties only if battery is present - Fix for offload incompletion due to delaySOD env stamping - Double dip with deeply depleted Supercap failure ?Fix - Adding PCI register initialization to PCI re init for cache offload v23.2.1-0023 (DFCT) Global activity LED does not work at all from 1403 or later. (DFCT) Cache Vault - No "Battery Removed" event when SuperCap is removed. v23.2.1-0021 (DFCT) HWR: 11M08: Event message is misleading Patrol Read corrected medium error on PD (DFCT) PKG 1400/Controller RMS25AB080 C1 with 1GB TMMB/After pinning the cache on an R1, hitting reset, the cache is lost. v23.1.1-0004 (DFCT) FW: CacheCade VD cleared event log has a wrong VD number. (DFCT) DSW II: hotspare Power state change during CC is incorrect (DFCT) SMI-S: The value of CurrentCachePolicy becomes invalid after changing Logical Drive cache mode. (DFCT) FUA bit should be set for the write i/o in case rebuild write cache enable (DFCT) Revert back the original rebuild progress logic (DFCT) Hit Kill Adapter During Heavy I/O & Rebuild (DFCT) HWR: LDBBM does not consistently handle medium errors during R6 rebuild (DFCT) FW: Snapshot roll back causes FW fatal error : Linu 278 in ../../raid/1078int.c. (DFCT) PEReplyDelay value can't be changed with NVDATA value (DFCT) WLK1.6 Read Capacity 16 Unit Test - SCSI Compliance - FAILS (DFCT) killadapter when running I/O on SUN sparc (CR) WebBIOS : Do not let WebBIOS to display "Chip Temperature (Celsius)". (CR) FW Re-activate the user option to enable Patrol Read on SSD. v21.1.1-0111 (DFCT) Dummy Defect to complete 10M12 patch stream tasks (DFCT) fw hit montask at pd.c when rebuilding from raid 6 (DFCT) Porting fix for the defect - Kill Adapter after 62 cycles of cable pull/push with I/O (DFCT) I/O miscompares when issue OCR. (DFCT) 10M09 to 10M12_patch merge issue and compiler error (DFCT) Return status code 'Success' to certain obsolete SCSI commands (DFCT) Liberator FW 10M09 cause system (sles11sp1/rhel6) reset while lspci -vvxxx is used (DFCT) sscd show 0 byte in debugger and MSM (DFCT) Application has advanced software options listed. This needs to be removed for Catera OEM (DFCT) Drive comes up as unconfigured bad while running power cycle and error injection script (DFCT) ekms bios is not enable (DFCT) Inconsistent drive state after drives are changed to different slots. (DFCT) Clear configured with SSC degraded causing FW went to mon_tsk() (DFCT) With multipath setting, found data miscompare while IOs across 2 enclosures (DFCT) FW doesnt detect the iBBU08 if it is remotely mounting with Farmington controller (DFCT) AI after code review on 03-02-2011 (DFCT) DateOfFirstuse is Incorrectly Causing BBU Deep Discharge Requirement (DFCT) Controller hit montask during BGI (DFCT) Configured PDs become not supported PDs, LDs dropping offline. (DFCT) Liberator FW 10M09 cause system (sles11sp1/rhel6) reset while lspci -vvxxx is used (DFCT) Controller reports "phy is bad" for single port with any SATA device (DFCT) HSP commissioned alarm beep goes away after reboot (DFCT) Port fixes from Perc8 (DFCT) port 2TB error handling changes (DFCT) FW aborts the recovery resulting SES not responding (DFCT) Provide mechanism to bypass settings delayPOST and envDelaySOD (CR) Deliver HII in Q1 2011 Liberator maintenance v21.1.1-0110 (DFCT) Enable Redirect Path in FW for FP disabled case v21.1.1-0105 - Initial release *Third-party trademarks are the property of their respective owners.