This release note and the software that accompanies it are copyright (c) 2017, Intel Corporation or its suppliers, and may only be installed and used in accordance with the license that accompanies the software. This Software is furnished under license and may only be used or copied in accordance with the terms of that license. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. The Software is subject to change without notice, and should not be construed as a commitment by Intel Corporation or its suppliers to market, license, sell or support any product or technology. Unless otherwise provided for in the license under which this Software is provided, the Software is provided AS IS, with no warranties of any kind, express or implied. Except as expressly permitted by the Software license, neither Intel Corporation nor its suppliers assumes any responsibility or liability for any errors or inaccuracies that may appear herein. Except as expressly permitted by the Software license, no part of the Software may be reproduced, stored in a retrieval system, transmitted in any form, or distributed by any means without the express written consent of Intel Corporation. ========================== Supported RAID Controllers ========================== This download supports Intel(R) RAID controllers using SAS software stack (RMSP3AD160F, RMSP3CD080F, RMSP3HD080E, RSP3TD160F, RSP3DD080F, RSP3MD088F, RMSP3LD060/AHWBPBGB24R, RSP3WD080E, RMS3AC160, RMS3CC080, RMS3CC040, RMS3HC080, RS3YC, RS3LC, RS3SC008, RS3MC044, RS3DC080, RS3DC040, RS3WC080, RCS25ZB040, RCS25ZB040LX, RMS25PB080, RMS25PB040, RMT3PB080, RMS25CB080, RMS25CB040, RMT3CB080, RMS25CB080N, RMS25PB080N, RS25AB080, RS25SB008, RS25DB080, RS25NB008, RS2VB080, RS2VB040, RT3WB080, RS2WC040, RS2WC080, RS2SG244, RS2WG160, RMS2MH080, RMS2AF080, RMS2AF040, RS2MB044, RS2BL080, RS2BL080DE, RS2BL040, RS2PI008DE, RS2PI008) For 1078 based controllers including SRCSASJV, SRCSASRB, SRCSATAWB, SROMBSASFC, SROMBSASMP2, SROMBSASMR, SRCSASPH16I, SRCSASBB8I, SRCSASLS4I and 1068 based controllers including SRCSAS18E, SRCSAS144E, SROMBSAS18E, please use the Windows inbox drivers. =================== Package Information =================== Driver Version = 7.701.04.00 OS supported = Windows Server 2016, Microsoft* Windows 10 (x86 & x64), Windows Server 2012 R2, Windows 8.1 (x86 & x64), Windows Server 2012, Windows 8 (x86 & x64) ========= Attention ========= This release supports the Windows Driver Configuration Utility (WDCFG) as per Microsoft requirement (DEVFUND-0046). Please see "user guide - windows driver configuration utility.pdf" for instructions on how to use this tool. ================== Known Restrictions ================== Windows XP X86 OS version is not supported as it does not support Storport driver required for MegaRAID Drivers. ======================= Contents on the package ======================= Name: Description: MR_Windows_DRV_v7.701.04.00_readme.txt This file License_v2.pdf License file Win8_x86\ Drivers for Windows 8 Win8_x64\ Drivers for Windows 8 and Windows Server 2012 x64 Win8.1_x86\ Drivers for Windows 8.1 Win8.1_x64\ Drivers for Windows 8.1 and Windows Server 2012 R2 x64 win10_x86\ Drivers for Windows 10 win10_x64\ Drivers for Windows 10 x64 and Windows Server 2016 Install the driver from the appropriate folder for your Windows version. ========================= Installation Instructions ========================= This updated driver can be applied using the normal OS installation options. Extract package contents to a user specified location such as = a:\ or a USB flash drive. Driver Installation Instructions for Windows* 2012/8 ---------------------------------------------------------------- a) This procedure installs the Intel RAID device driver on a new Windows* 2012/8 system. Windows 2012/8 automatically adds the driver to the registry and copies the driver to the appropriate directory. ---------------------------------------------------------------- 1. Start the Windows installation by booting from the Windows 2012/8/2008/7 DVD-ROM. The system BIOS must support booting from a DVD-ROM. BIOS settings might require changes to allow DVD-ROM booting. See your system documentation. 2. When the screen displays: "Where do you want to install Windows?", select 'Load Driver', then click Next. 3. The system prompts for a Load Driver dialogue to ask for the manufacturer-supplied hardware driver disk. Insert the driver diskette containing the Windows 2012/8/7/2008 device driver, and press . NOTE: You may ask to supply the appropriate INF path if you want to load driver from a USB flash drive. 4. Select the Windows device driver from the menu by highlighting it, then click Next. 5. Remove the USB flash drive. Follow the Microsoft Windows installation procedure to continue the OS installation. ---------------------------------------------------------------- b) This procedure installs or updates the Intel RAID device driver on an existing Windows 7/2008 system. ---------------------------------------------------------------- 1. Boot Windows. 2. Under Control Panel, select Administrative Tools -> Computer Management. Then Select Device Manger and identify the new add-in device. Double click the device, then select the Drier Page, click Update Driver to install the new driver. 3. Insert the driver diskette into the A:\ drive. 4. Click the 'Browse My computer for driver software' button. 5. Click the 'Browse' button to specify the driver disk location A:\ 6. Click the 'Next' button then system will search driver in the specified location and install the driver automatically. 7. Click the 'Close' button to complete the driver installation. 8. Repeat this process for all the controllers on your system. Changes from 7.701.03.00 to 7.701.04.00 1) SCGCQ01301420 MR7.1 OEM I/O tool gets fatal error and stops with outstandings IO Changes from 7.701.02.00 to 7.701.03.00 1) SCGCQ01274041 MR 7.1 SAS3508: Redirect HEIOs larger than MDTS to NVME back to normal build routine 2) SCGCQ01274015 MR SAS3508 7.1 : Wrong reference of Raid map DevhandleInfo to fetch interface type in HEIO path 3) SCGCQ01279401 MR 7.1:All sequential streams on R5/R6 WT, NORA, DIO need to be issued to CPU 0 if they are set to FCFS for writes 4) SCGCQ01278602 Add OEM PNP IDs Changes from 7.701.01.00 to 7.701.02.00 1) SCGCQ01262651 MR-7.1-Windows-Driver: CHAOS WRITE IOs hang on R50 and R6 VDs on Windows 8 x86 2) SCGCQ01266012 Change the DebugOutput to DebugOutPutVerbose in heio_path.c 3) SCGCQ01270126 SAS3508 MR 7.1 Windows NVMe: JBOD Large Sequential MB/s do not meet targets Changes from 7.701.00.00 to 7.701.01.00 1) SCGCQ01265412 MR SAS3508 7.1 : Cisco - add PnP ID for Cisco rebranded Talladega card Changes from 7.101.15.00 to 7.701.00.00 1) SCGCQ01171653 Remove SAS3508 EVAL support from MR Windows Driver 7.1 when Code goes Beta 2) SCGCQ01259466 MR 7.1: BSOD on Raidmap NULL pointer in the NonRW build routine 3) SCGCQ01260224 MR 7.1 update Copyright Information Changes from 7.101.14.00 to 7.101.15.00 1) SCGCQ01250023 SJ Perf BST Win driver 7.101.13 shows 56% Regressions on Seq/Ran reads R10s on SSDs, 60% SATA HDD SeqWrt Changes from 7.101.13.00 to 7.101.14.00 1)SCGCQ01249367: MR WINDOWS DRIVER doesnt set MDTS value correctly in BuildIOs Changes from 7.101.12.00 to 7.101.13.00 1) SCGCQ01246988 MR 7.1 : windows 7 QD limit should be 1000 2) SCGCQ01246860 MR 7.1: Driver Ignores Large R1 READ IOs from redirecting to LDIOs [R1 PCI BW changes] 3) SCGCQ01246848 MR 7.1 SAS3508 NVMe: Driver Fires larger than MDTS IOs as FPIO instead of LDIO Changes from 7.101.11.00 to 7.101.12.00 1)SCGCQ01240829-MR 7.1 NVMe_Windows 10 does not resume after hibernation Changes from 7.101.10.00 to 7.101.11.00 1) SCGCQ01229303 MR7.1 SJ Perf BST 16 DA SATA SSD and 24 SAS SSD 30-70% regressions R10 Writes 4K QD1-256 compare to MR7 RC driver 2) SCGCQ01233023 For 9460-8i 2GB controller, OEM needs Windows driver to reflect its branding name, NVdata and SBR added to MR FW packages 3) SCGCQ01234624 For 9460-16i 4GB and 9460-16i 8GB controllers, OEM needs Windows driver to reflect its branding name, NVdata and SBR added to Changes from 7.101.09.00 to 7.101.10.00 1) SCGCQ01235974 OCR is not working with driver 7.101.09.00 Changes from 7.101.08.00 to 7.101.09.00 1) SCGCQ01228969 MR7.1-NVME: MR_DCMD_DEV_GET_TARGET_PROP : LD 255 is invalid/not found are observed in logs. 2) SCGCQ01230552 MR 7.1 NVMe : Assertion failure in ../../raid/ldCmd.c at line 825: 0 , while creating multiple R0 VD`s 3) SCGCQ01183799 CSET: MR 6.13 PA2: MonTask: line 1284 in file ../../raid/1078dma.c on triggering IO timeouts from jammer on JBOD's. - (SCGCQ01166321) 4) SCGCQ01229303 MR7.1 SJ Perf BST 16 DA SATA SSD and 24 SAS SSD 30-70% regressions R10 Writes 4K QD1-256 compare to MR7 RC driver Changes from 7.101.07.00 to 7.101.08.00 1) SCGCQ01227464 MR SAS3508 7.1: Sync MR API to Latest FW API 2) SCGCQ01227468 MR SAS3508 7.1 : R1PCI BW changes does not take into account Large IOs produced by Coalescing Logic Changes from 7.101.06.00 to 7.101.07.00 1) SCGCQ01180457 SAS3508 MR - 24 SAS SSD R10 4K RW missing product goal/not scaling properly 2) SCGCQ01206478 Add Interface to MR WINDOWS for Max Transfer IO size 3) SCGCQ01214400 MR7.1_NVMe:BSOD observed in windows 7 if server hibernate with pinned cache Changes from Sync with MR 7.0.1 Stream 1) SCGCQ01213040 sync MR7.1 with MR7.0 7.700.00.00 2) SCGCQ01178218 MR7 PNP additions 3) SCGCQ01204525 For nonRW JBOD IOs driver is not using correct targetID 4) SCGCQ01197656 BSoD DRIVER_IRQL_NOT_LESS_OR_EQUAL (d1) during raidmap update 5) SCGCQ01197660 Update the wdcfg for NanoServer Changes from 7.101.05.00 to 7.101.06.00 1) SCGCQ01183876 MR7.1_NVMe: MonTask: line 1636 in file ../../inc/raid.h while deleting single drive R0 VD with IOs 2) SCGCQ01206118 BSOD while OCRing 3) SCGCQ01182821 Data Corruption on Degraged 3 span R10 64K stripe size ARA,WT,DIO Changes from 7.101.04.00 to 7.101.05.00 1) SCGCQ01202696 MR SAS3508: Driver doesn't honor acrossstripe capabilities for HEIO path (Single Drive R0) Changes from 7.101.03.00 to 7.101.04.00 1) SCGCQ01169217 TimeStamp each IO using background timer 2) SCGCQ01170652 OS is crashing while running I/Os in 2 iMR controllers 3) SCGCQ01188729 CSET: Driver Triggers OCR even if its disabled in Case of IO timeout . - (SCGCQ01188727) 4) SCGCQ01186295 PDs pull / push caused BSOD 5) SCGCQ01183798 CSET: Windows OS Crash observed, while forcefully deleting the R1 VD in presence of BG IO's - (SCGCQ01176591) Changes from 7.101.02.00 to 7.101.03.00 1) SCGCQ01175112 Code Refactor for BuildSGL 2) SCGCQ01099824 Provide registry to Disable StreamDetection 3) SCGCQ01177870 Disable NVMe support in 7.0 driver 4) SCGCQ01173833 Overnight OCR lost controller becasue FW is waiting for driver to set the hot plug bit 5) SCGCQ01171125 Intel Dunes Windows Driver String changes 6) SCGCQ01178280 ReEnable NVMe Support in 7.1 7) SCGCQ01149673 Marlin A0: IO Timeout seen during OCR testing 8) SCGCQ01163979 CSET: Update WDCFG.exe for Windows Server 2016 Nanoserver Support . - (SCGCQ01163861) 9) SCGCQ01176591 MR7.1_NVMe: Windows OS Crash observed, while forcefully deleting the R1 VD in presence of BG IO's 10) SCGCQ01183799 CSET: MR 6.13 PA2: MonTask: line 1284 in file ../../raid/1078dma.c on triggering IO timeouts from jammer on JBOD's. - (SCGCQ01166321) Changes from 7.101.01.00 to 7.101.02.00 1) SCGCQ01171618 NVMe SAS3508: Add support for Eval Boards Changes from 7.100.87.00 to 7.101.01.00 1) SCGCQ01164945 SAS3508 NVMe: Coalescing condition limits NVMe FPIO size to less than 20k instead of 20k 2) SCGCQ01164456 SAS3508 NVMe: Num SGEs set to 0xfffff causes FW assertion 3) SCGCQ01169038 SAS3508 NVMe: Driver Fails to recognize NVMe Drives 4) SCGCQ01169649 CSET: Marlin A0: IO Timeout seen during OCR testing - (SCGCQ01149673) MR7.0.1 Changes from 7.700.24.00 to 7.700.25.00 1) SCGCQ01258943 Drop support of devid 0x0015 for 7.0.1/7.1 Changes from 7.700.22.00 to 7.700.23.00 1) SCGCQ01235504 CSET: MR 6.13 PA2: MonTask: line 1284 in file ../../raid/1078dma.c on triggering IO timeouts from jammer on JBOD's. - (SCGCQ01166321) 2) SCGCQ01235836 Update the generic name for MR7 controller 3) SCGCQ01238036 Windows Host crashes when collecting kernel dump using debug driver Changes from 7.700.21.00 to 7.700.22.00 1) SCGCQ01174460 PERC10 - R0 PI enabled VD drops during heavy IO with multiple VD policy changes Changes from 7.700.20.00 to 7.700.21.00 1) SCGCQ01221486 MR SAS3508 7.0.1 : Disable Debug Framework for Release Builds as it impacts performance Changes from 7.700.00.00 to 7.700.20.00(MR7.0.1) 1) SCGCQ01209114 First Time Data Capture(FTDC) Debug Framework in driver Changes from 7.100.94.00 to 7.700.00.00 1) SCGCQ01209286 Set version number of MR7.0 Changes from 7.100.93.00 to 7.100.94.00 1) SCGCQ01182821 Data Corruption on Degraged 3 span R10 64K stripe size ARA,WT,DIO 2) SCGCQ01206118 BSOD while OCRing Changes from 7.100.92.00 to 7.100.93.00 1) SCGCQ01178218 MR7 PNP additions 2) SCGCQ01204325 CSET: MR SAS3508: Driver doesn't honor acrossstripe capabilities for HEIO path (Single Drive R0) - (SCGCQ01202696) 3) SCGCQ01204525 For nonRW JBOD IOs driver is not using correct targetID Changes from 7.100.91.00 to 7.100.92.00 1) SCGCQ01197656 BSoD DRIVER_IRQL_NOT_LESS_OR_EQUAL (d1) during raidmap update 2) SCGCQ01197660 Update the wdcfg for NanoServer Changes from 7.100.90.00 to 7.100.91.00 1) SCGCQ01170652 OS is crashing while running I/Os in 2 iMR controllers Changes from 7.100.89.00 to 7.100.90.00 1) SCGCQ01188729 CSET: Driver Triggers OCR even if its disabled in Case of IO timeout . - (SCGCQ01188727) 2) SCGCQ01186295 PDs pull / push caused BSOD 3) SCGCQ01183798 CSET: Windows OS Crash observed, while forcefully deleting the R1 VD in presence of BG IO's - (SCGCQ01176591) Changes from 7.100.88.00 to 7.100.89.00 1) SCGCQ01175112 Code Refactor for BuildSGL 2) SCGCQ01099824 Provide registry to Disable StreamDetection 3) SCGCQ01177870 Disable NVMe support in 7.0 driver 4) SCGCQ01173833 Overnight OCR lost controller becasue FW is waiting for driver to set the hot plug bit 5) SCGCQ01171125 Intel Dunes Windows Driver String changes Changes from 7.100.87.00 to 7.100.88.00 1) SCGCQ01149673 Marlin A0: IO Timeout seen during OCR testing 2) SCGCQ01163979 CSET: Update WDCFG.exe for Windows Server 2016 Nanoserver Support . - (SCGCQ01163861) Changes from 7.100.86.00 to 7.100.87.00 1) SCGCQ01154712 remove support for devID 00AA-00AF, 00D0-00D1 2) SCGCQ01157968 for SysPDs print failing INQ cmds 3) SCGCQ01158304 SAS3508 B0: Chain pointer in SGL not set when IO is build through HEIO path. Changes from 7.100.85.00 to 7.100.86.00 1) SCGCQ01149297 PA5 A0 MR: fw hit KA when doing a few of cable pull 2) SCGCQ01145232 SAS3508 Nvme: Driver is forming PRPs for LD IO Changes from 7.100.84.00 to 7.100.85.00 1) SCGCQ01144484 Update Windows driver to use new pdTargetId field for JBOD target ID 2) SCGCQ01146582 Rebuild IO if it bailed out from HEIO-startIO routine 3) SCGCQ01146604 PR11 R1FPW not enabled in Windows driver Changes from 7.100.83.00 to 7.100.84.00 1) SCGCQ01141177 Use StroportRequestTimer to run BackGroundTimer 2) SCGCQ01144567 Disable HEIO flag is IO going thru regular IO path 3) SCGCQ01113332 CSET: EXSDS : Kill adapter Seen when running IO's on JBOD with SPACES volumes and Cable breaker on one of the active path . - (SCGCQ01095397) 4) SCGCQ01108836 CSET: Allow Sync CACHE Command for Invader and Intruder controllers by MR Windows Driver - (SCGCQ01100038) 5) SCGCQ01144608 Sync to API -07/21/2016 6) SCGCQ01145007 Support Laguna Beach and Laguna Beach Plus Changes from 7.100.82.00 to 7.100.83.00 1) SCGCQ01125459 PA5 A0 MR: OS did not generate memory dump when trigger fault using notmyfault. 2) SCGCQ01132172 Assertion failure in ../../raid/mpthostcmd.c at line 1429: DMGetArmFromDevhandle( pMpt->DevHandle) == physArm when pull drive 3) SCGCQ01129484 Check for MaxSges in coalescing logic is incorrect Changes from 7.100.81.00 to 7.100.82.00 1) SCGCQ01122476 SAS3508 A0: Handle failure to allocate Peer SRBExt in case of R1FPW 2) SCGCQ01127471 Offline drive in R1 casue KA in Windows Changes from 7.100.80.00 to 7.100.81.00 1) SCGCQ01112135 Debug driver 7.100.80.01 does not install on Windows 2012 R2 2) SCGCQ01107421 Firmware asserted at /raid/mpthostcmd.c at line 1433: DMGetArmFromDevhandle( pMpt->DevHandle) == ph when degraded R1 VDs” 3) SCGCQ01113650 Release note for Windows driver 7.100.80 typo/ missing Changes from 7.100.79.00 to 7.100.80.00 1) SCGCQ01108462 Windows crashed while creating LDs Changes from 7.100.78.00 to 7.100.79.00 1) SCGCQ01108264 MR7 PNP additions Windows Driver 2) SCGCQ01107317 Windows driver 7.100.78.00 hang during boot up when enclosure is attached 3) SCGCQ01096265 Windows crashed "DRIVER_IRQL_NOT_LESS_OR_EQUAL (megasas35.sys) while creating LDs Changes from 7.100.77.00 to 7.100.78.00 1) SCGCQ01095943 MR-SAS3508: Windows 2012 R2 Disk Manager doesn't detect newly created JBODs Changes from 7.100.76.00 to 7.100.77.00 1) SCGCQ01092621 A0 Talladega EVT2, drives pull while IOs caused BSOD with error mesg megaraid35.sys Changes from 7.100.75.00 to 7.100.76.00 1) SCGCQ01074770 Large SEQ IO for R1 LD to be sent to FW as LD IO 2) SCGCQ01088908 Support Dynamic Raid Map 3) SCGCQ01088879 Pick Latest API Dated 05142016 4) SCGCQ01088886 If lunReset not supported then return correct status 5) SCGCQ01086087 Remove Liberator\Falcon code 6) SCGCQ01086101 Code rearragne\cleanup Changes from 7.100.74.00 to 7.100.75.00 1) SCGCQ01080033 A0 SAS3508 EVAL : Single Core 6305 IOSubtype is incorrectly set for JBOD RW IOs 2) SCGCQ01071586 MR evt2: OS crash when come back from hibernation. 3) SCGCQ01081977 Disable coalescing via raidmap 4) SCGCQ00806792 SAS3508: OS Currency 5) SCGCQ01081985 Add Registry entry to disable dualQdepth 6) SCGCQ01081989 Collect AENs from latest after OCR 7) SCGCQ01081995 CSET: Merge eSDS stream into MR 6.12 Mainline Windows Driver(only for Win10) - (SCGCQ01002558) 8) SCGCQ01080169 CSET: Handling the Task Management request issued to the VDs. - (SCGCQ00869511) 9) SCGCQ01082005 Support Intel 4part IDs for SAS3508 controller Changes from 7.100.73.00 to 7.100.74.00 1) SCGCQ01078365 CSET: Handle Sequence Mismatch in MR WINDOWS DRIVER using a timer - (SCGCQ01019522) 2) SCGCQ01074235 NVMe Performance Improvements 3) SCGCQ01071321 Coalescing changes to Flush IOs quickly when coalescing limit is matched 4) SCGCQ01074815 Disable R5RMW FP IO 5) SCGCQ01074820 DCMDs to use atomic descriptors 6) SCGCQ01078428 CSET: Increase the Timeout Value of DCMDs to 180 seconds for Sleep and Shutdown during aborting Pended Commands . - (SCGCQ00929333) 7) SCGCQ01078429 Add Marlin (0xD0) and Mercator(0xD1) to MegaRAID Windows Driver 8) SCGCQ01075803 Flush Coalesce IO when it reached maxSGE or Coalsize limit Changes from 7.100.72.00 to 7.100.73.00 1) SCGCQ01069810 CSET: CSCuz12923 : SF:MSM AEN is not generating controller reset events in Windows - (SCGCQ01063100) 2) SCGCQ01071321 Coalescing changes to Flush IOs quickly when coalescing limit is matched 3) SCGCQ01068941 SAS3508 MR: R10 WT/WB SW, SAS/SATA 4K High QD Changes from 7.100.71.00 to 7.100.72.00 1) SCGCQ01065876 BSoD observed when we load 7.100.71.00 driver Changes from 7.100.70.00 to 7.100.71.00 1) SCGCQ01065267 Handle nonVDIO for dual QDEPTH for R1FPW 2) SCGCQ01065272 Set R5RMW state to notSupported if DMCD MR_DCMD_LD_RMW_FP_OPS fails 3) SCGCQ01044049 SAS3508 EVT2, system is NOT shutdown when user trying to shutdown the system during RECON + IOs 4) SCGCQ01063645 CSET: MonTask: line 1954 in file ../../raid/2108vI2o.c when run I/O and trigger OCR - (SCGCQ01019278) Changes from 7.100.69.00 to 7.100.70.00 1) SCGCQ01059664 MR SAS3508 COL : Firmware hit kill adapter when trigger OCR ( debugOcr reset 0 0 ) Changes from 7.100.68.00 to 7.100.69.00 1) SCGCQ01046096 Add the registry entry of StorPort PowerSrbTimeout for Miniport driver for Server 2016 - (SCGCQ01046075) 2) SCGCQ01057386 Driver loses JBOD disk after OFU from 6.10 to 6.4 - (SCGCQ01056377) 3) SCGCQ01058642 MR_SAS3508 : Support NVMe PRP in Hi Efficiency Path. 4) SCGCQ01057078 Incorrect NVMe PRP Build and Fire routines Changes from 7.100.67.00 to 7.100.68.00 1) SCGCQ01053417 Enhance Driver debug code 2) SCGCQ01053424 Route R5WT LDIO Streamed Write from FCFS to CPU0 3) SCGCQ01053426 Allow Stream Detection if Coalescing is disabled 4) SCGCQ01053428 High Efficiency Raid 0 code path for Single Driver R0 5) SCGCQ01047928 Driver ignores FPread/write accross stripe capabilities 6) SCGCQ01048932 New HWIDs for SAS3508 7) SCGCQ01053441 Enable Win10 build for SAS3508 8) SCGCQ01053435 After running a stream IO performance drops from 700K to 300K Changes from 7.100.66.00 to 7.100.67.00 1) SCGCQ01039100 A0Rework: FW6130 montask when set Pd offline for second LD(SpanArm issue) 2) SCGCQ01045933 Windows Driver 66 crashed into BSOD while I/Oing 3) SCGCQ01047819 Set ContextType correctly(to 2) for nonRWFPIO Changes from 7.100.65.00 to 7.100.66.00 1) SCGCQ01041467 Implement SQN ad FWN bit in routing Flags 2) SCGCQ01042762 TimeStamp the IO and Have different Debug Level for Debug driver 3) SCGCQ01034343 R5 Seq W Full Stripe Wrt , less than half the performance of Invader 4) SCGCQ01029289 CSET: Set Windows Registry Entry to NoClobber for MR WINDOWS DRIVER - (SCGCQ01025992) 5) SCGCQ01030198 CSET: set the capability bit for 1MIO support and Dual QD support conditionally - (SCGCQ00938984) 6) SCGCQ01030072 CSET: MR_6.10: Region length mismatch while running IO's on VD's with multipath push pull - (SCGCQ00936554) 7) SCGCQ01042726 Invalid descriptor type IO received by firmware on FPE exception. 8) SCGCQ01044278 Correct the order for Synronize Shutdown State machine Changes from 7.100.64.00 to 7.100.65.00 1) SCGCQ01038382 Atomic Descriptor fixes for some IO code path 2) SCGCQ01034414 A0 board, R1/R10 can't make partition with default NRA/WT/DIRECT 3) SCGCQ01026844 Performance improvements for SAS3508 Driver Changes from 7.100.63.00 to 7.100.64.00 1) SCGCQ01034226 Re-enabling R1FPW Changes from 7.100.62.00 to 7.100.63.00 1) SCGCQ01032039 Remove QuadAlignment restriction 2) SCGCQ01032054 Handle proper completion if IOs for R5 RMW 3) SCGCQ01028304 Fix the EOL for NVME frames correctly Changes from 7.100.61.00 to 7.100.62.00 1) SCGCQ01026277 Hit blue screen when install windows driver 7.100.59.0 Changes from 7.100.60.00 to 7.100.61.00 1) SCGCQ01027347 Temporarily Disable R1 FP write code path 2) SCGCQ01021636 Driver 7.100.60.00 cause firmware crashed during import VDs and when first upgrade Changes from 7.100.59.00 to 7.100.60.00 1) SCGCQ01019269 SAS3508 MR R10 only reading from half the drives 2) SCGCQ01021589 Enhance QueueDepth calculation Changes from 7.100.58.00 to 7.100.59.00 1) SCGCQ01010803 Re-Enable 240 VD support 2) SCGCQ01006869 SAS3508 MR : Pom Data corruption with MR_PD_INFO_GET Dcmd Changes from 7.100.57.00 to 7.100.58.00 1) SCGCQ00564847 Refactor driver design to remove latency in IO path Changes from 7.100.56.00 to 7.100.57.00 1) SCGCQ00812213 SAS3508: Greater than 1000 IOs Support 2) SCGCQ01011080 SAS3508: New hwid support *Third-party trademarks are the property of their respective owners.